Yokogawa EJXC40A Digital Remote Sensor

EJXC40A Digital Remote Sensor (DRS) Transmitter connects two pressure sensors, master (high pressure side) and slave (low pressure side) in a remote location, with dedicated electrical cable to measure differential pressure.
EJXC40A is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure and outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.

Key Features

  • High performance, high accuracy and high reliability
    Better performance over long capillaries of diaphragm seal system.
  • Suitable for level measurement of a tall tank
    DRS cable length (maximum): 45 m
  • Signal characterization for various tank types
EJXC40A

Our Main Business on :EJA210E,EJX210A,EJXC40A,EJXC80A, EJAC80E (Diaphragm Seal),EJXC80A, EJAC80E (Direct Mounted),EJXC50A, EJAC50E…All the Yokogawa Pressure Transmitter we sell Made in Japan! 100% Original!

EJXC40A Digital Remote Sensor (DRS) Transmitter 
connects two pressure sensors, master (high pressure
side) and slave (low pressure side) in a remote
location, with DRS dedicated communication cable to
measure differential pressure. EJXC40A is suitable to
measure liquid, gas, or steam flow as well as liquid
level, density and pressure and outputs a 4 to 20 mA
DC signal corresponding to the measured differential
pressure. Monitoring or parameter setting can be
remotely done via HART communication.

Digital Remote Sensor (DRS) can provide the solutions of …

  • No limitation of higher tank height
  • Stable tank level measurement with minimized temperature effect
  • Single Sensor Accuracy:
    • 0.055% of span
    • 0.025% of span (for EJX630 screwed mount/HAC)

Wide Range Differential Pressure Measurement

  • Screwed types: up to 50MPa
    • Up to 70MPa (for EJX630-Dcapsule screwed mount)
  • Flange types: up to flange rating

Digital Remote Sensor (DRS) is connecting two transmitters electrically,
so it’s not influenced by solar radiation and temperature change.

Items Specifications
Output Signal HART7
Variables PV%/ DP/ Master-P/ Slave-P/ Engr. PV/ Master-T/ Slave-T/ AMP Temperature (Master)/ Output Current Value
Measurement Span Range: 0-0.2/2/10/50MPa  (in case of EJX530A)
Range: 0-0.2/2/10/70MPa  (in case of EJX630A)
(Flange model: up to Flange Rating)
Accuracy +-0.055% of span (single sensor accuracy with flange)
(Accuracy of screwed-mount type is same as normal transmitters’ accuracy 0.04% or 0.025% for EJX630 with /HAC. System accuracy can be calculated by configuration-tool)
Long Term Stability 0.1% of URL per 10 years (All normal operating condition)
Temperature Effect
@50℉ (28℃) change
0.14% span + 0.028% URL (sensor)
(System accuracy can be calculated by Configuration-Tool)
Response Time 250ms (Update Period: 90ms)
Cable length 15/30/45 m