ABB DCS800 DC Drive
What is an DCS800 DC Drive?
The DCS800 DC Drive is simple to buy, install, confi gure
and use, saving considerable time.
* Precise delivery
* Quick installation
* Rapid startup
The drive has common user and process interface with
fi eldbus, common software tools for sizing, commissioning,
maintenance and common spare parts.
DCS800 DC Drive promises
The drive meet the requirement of all demanding drive
application like: • testrig • mine hoist • rolling mill
as well as none motoric applications like: electrolysis •
magnetics • battery charger …
Embedded software functions offer the upgrades of all
classic installations 12-pulse, shared motion, double
motor operation, fi eld reversal control.
Where can it be used?
DCS800 can be used in the wide range of all industrial
application of
* Metals * Vessels
* Pulp & Paper * Ski lifts
* Material handling * Magnets
* Test rigs * Mining
* Food & Beverage * Electrolysis
* Printing * Battery Chargers
* Plastic & Rubber * and more
Highlights
* Assistant control panel providing intuitive use of
the drive.
* Excellent control performance up to highest dynamic
application in fi eld weakening operation.
* All ACS800 PC tools (via DDCS) can be connected
* Reduced installation and commissioning work.
* Internal three phase fi eld exciter without additional
external hardware.
* Prepared for addtional software function by adaptive
programming and IEC1131 programming.
* Flexible fi eldbus system with built-in Modbus and
numerous internally mountable fi eldbus adapters.
ABB DCS800 Power Converter Modules
General:
The power converter modules DCS800-S0x have the protection class IP00 and are to be mounted in a cubicle or fi nger protected area. There are different sizes (D1, D2, D3, D4, D5, D6, D7), graduated in terms of current and voltage ranges.
All units are equipped with control panel DCS 800PAN. It can be snapped into place on the power converter module or installed in the switchgear cubicle door by means of a mounting kit.
Reference variables:
The voltage characteristics are shown in the table


beside. The DC voltage characteristics have been
calculated using the following assumptions:
• UVN = rated input terminal voltage, 3-phase
• Voltage tolerance ±10 %
• Internal voltage drop approx. 1%
• If a deviation or a voltage drop has to be taken
into consideration in compliance with IEC and
VDE standards, the output voltage or the output
current must be reduced by the actual factor
according to the table on the right.
ABB DCS800 DC Drive Dimensioning/DriveSize
Quality dimensioning
DriveSize is a PC program for helping the user to select an optimal converter and options, especially in those cases where a straightforward selection from a catalogue is not possible. Documents about the dimensioning based on actual load.
The default values make DriveSize simple to use, but the user is provided with many options for drive selection. The shortcut keys make drive selection easy while still honouring the relatively complicated rules. A manual selection mode is also supported.
DriveSize is currently used by more than 1000 engineers globally.
DriveSize is for drive system components 


• DCS converter modules
• DCS enclosed converters
• Group drives (line-ups)
• Drive options
DriveSize features
• Select an drive unit, incoming unit
• Calculate duty load cycles for converters
• Supply dimensioning results in graphical and numerical format
• Print and save the results
DCS800 DC Drive Startup Assistant
Faster and easier commissioning
The Startup Assistant serves in DCS800 DC Drives. It guides you actively through the commissioning procedure either by the control panel or ABB PC tools. It is multilingual, requests data with clear and plain text messages, and sets the required parameters to your needs. It also comes with an online info system with step-by-step reference to printed manuals.
On-line info system
To make it easier and more informative, there is an online info system available at each step, helping to set the correct values for each parameter and troubleshoot the problems.
Startup Assistant Features


• Easy and fast commissioning procedure
• Intelligent guide to assist you through the
commissioning
• Your own language
• On-line info system always available
• Auto detection of connected hardware
The DCS800 DC Drive offers you all this as standard
features.
DCS800 Series DC Drive
| Converter Type | Code Item | Input Voltage (V) | OutPut Current(A) | Quadrant | Field Current(A) | Frame Size |
| 模块型号 | 产品代号 | 输入电压 | 输出电流 | 象限 | 励磁电流 | 外型尺寸 |
| 400-500V 2 Quadrant | ||||||
| DCS800-S01-0020-05 | 3ABD00019966 | 3AC 400V~500V | 20A | 2Q | 6 | D1 |
| DCS800-S01-0045-05 | 3ABD00019968 | 3AC 400V~500V | 45A | 2Q | 6 | D1 |
| DCS800-S01-0065-05 | 3ABD00019970 | 3AC 400V~500V | 65A | 2Q | 6 | D1 |
| DCS800-S01-0090-05 | 3ABD00019972 | 3AC 400V~500V | 90A | 2Q | 6 | D1 |
| DCS800-S01-0125-05 | 3ABD00019974 | 3AC 400V~500V | 125A | 2Q | 6 | D1 |
| DCS800-S01-0180-05 | 3ABD00019976 | 3AC 400V~500V | 180A | 2Q | 15 | D2 |
| DCS800-S01-0230-05 | 3ABD00019978 | 3AC 400V~500V | 230A | 2Q | 15 | D2 |
| DCS800-S01-0315-05 | 3ABD00019981 | 3AC 400V~500V | 315A | 2Q | 20 | D3 |
| DCS800-S01-0405-05 | 3ABD00019984 | 3AC 400V~500V | 405A | 2Q | 20 | D3 |
| DCS800-S01-0470-05 | 3ABD00019986 | 3AC 400V~500V | 470A | 2Q | 20 | D3 |
| DCS800-S01-0610-05 | 3ABD00019990 | 3AC 400V~500V | 610A | 2Q | 25 | D4 |
| DCS800-S01-0740-05 | 3ABD00019992 | 3AC 400V~500V | 740A | 2Q | 25 | D4 |
| DCS800-S01-0900-05 | 3ABD00019994 | 3AC 400V~500V | 900A | 2Q | 25 | D4 |
| DCS800-S01-1190-05 | 3ABD00022540 | 3AC 400V~500V | 1,190A | 2Q | D4+ | |
| DCS800-S01-1200-05 | 3ABD00019997 | 3AC 400V~500V | 1,200A | 2Q | D5 | |
| DCS800-S01-1500-05 | 3ABD00019998 | 3AC 400V~500V | 1,500A | 2Q | D5 | |
| DCS800-S01-2000-05 | 3ABD00019999 | 3AC 400V~500V | 2,000A | 2Q | D5 | |
| 400V~500V,2 Quadrant | ||||||
| DCS800-S02-0025-05 | 3ABD00019967 | 3AC 400V~500V | 25A | 4Q | 6 | D1 |
| DCS800-S02-0050-05 | 3ABD00019969 | 3AC 400V~500V | 50A | 4Q | 6 | D1 |
| DCS800-S02-0075-05 | 3ABD00019971 | 3AC 400V~500V | 75A | 4Q | 6 | D1 |
| DCS800-S02-0100-05 | 3ABD00019973 | 3AC 400V~500V | 100A | 4Q | 6 | D1 |
| DCS800-S02-0140-05 | 3ABD00019975 | 3AC 400V~500V | 140A | 4Q | 6 | D1 |
| DCS800-S02-0200-05 | 3ABD00019977 | 3AC 400V~500V | 200A | 4Q | 15 | D2 |
| DCS800-S02-0260-05 | 3ABD00019979 | 3AC 400V~500V | 260A | 4Q | 15 | D2 |
| DCS800-S02-0350-05 | 3ABD00019983 | 3AC 400V~500V | 350A | 4Q | 20 | D3 |
| DCS800-S02-0450-05 | 3ABD00019985 | 3AC 400V~500V | 450A | 4Q | 20 | D3 |
| DCS800-S02-0520-05 | 3ABD00019987 | 3AC 400V~500V | 520A | 4Q | 20 | D3 |
| DCS800-S02-0680-05 | 3ABD00019991 | 3AC 400V~500V | 680A | 4Q | 25 | D4 |
| DCS800-S02-0820-05 | 3ABD00019993 | 3AC 400V~500V | 820A | 4Q | 25 | D4 |
| DCS800-S02-1000-05 | 3ABD00019995 | 3AC 400V~500V | 1,000A | 4Q | 25 | D4 |
| DCS800-S02-1190-05 | 3ABD00022540 | 3AC 400V~500V | 1,190A | 4Q | D4+ | |
| DCS800-S02-1200-05 | 3ABD00019997 | 3AC 400V~500V | 1,200A | 4Q | D5 | |
| DCS800-S02-1500-05 | 3ABD00019998 | 3AC 400V~500V | 1,500A | 4Q | D5 | |
| DCS800-S02-2000-05 | 3ABD00019999 | 3AC 400V~500V | 2,000A | 4Q | D5 | |
| 600V,2 Quadrant | ||||||
| DCS800-S01-0290-06 | 3ABD00019980 | 3AC 600V | 290A | 2Q | D3 | |
| DCS800-S01-0590-06 | 3ABD00019989 | 3AC 600V | 590A | 2Q | D4 | |
| DCS800-S01-0900-06 | 3ABD00019996 | 3AC 600V | 900A | 2Q | D5 | |
| DCS800-S01-1500-06 | 3ABD00019998 | 3AC 600V | 1,500A | 2Q | D5 | |
| DCS800-S01-2000-06 | 3ABD00019999 | 3AC 600V | 2,000A | 2Q | D5 | |
| 600V 4 Quadrant | ||||||
| DCS800-S02-0320-06 | 3ABD00019982 | 3AC 600V | 320A | 4Q | D3 | |
| DCS800-S02-0650-06 | 3ABD00019988 | 3AC 600V | 650A | 4Q | D4 | |
| DCS800-S02-0900-06 | 3ABD00019996 | 3AC 600V | 900A | 4Q | D5 | |
| DCS800-S02-1500-06 | 3ABD00019998 | 3AC 600V | 1,500A | 4Q | D5 | |
| 690V 2 Quadrant | ||||||
| DCS800-S01-0900-07 | 3ABD00019996 | 3AC 690V | 900A | 2Q | D5 | |
| DCS800-S01-1500-07 | 3ABD00019998 | 3AC 690V | 1,500A | 2Q | D5 | |
| DCS800-S01-2000-07 | 3ABD00019999 | 3AC 690V | 2,000A | 2Q | D5 | |
| 690V,4 Quadrant | ||||||
| DCS800-S02-0900-07 | 3ABD00019996 | 3AC 690V | 900A | 4Q | D5 | |
| DCS800-S02-1500-07 | 3ABD00019998 | 3AC 690V | 1,500A | 4Q | D5 | |