ABB DCS400 ABB Drive ABB DC Drive

Data

Mains supply
Voltage – power part, 3-phase 230V to 500V in acc. with IEC 38
Voltage deviation +/- 10% permanent
Rated frequency 50Hz or 60Hz
Voltage – electr. supply, 1-phase 115V to 230V in acc. with IEC 38
Voltage deviation -15% / +10%
Frequency range 45Hz to 65Hz
Voltage – fan supply, 1-phase no fan (units up to 25A)
115V / 230V (units 45A to 550A) 
230V (units 610A to 1000A) or optional 115V
Degree of protection IP 00
DC outputs
DC motor voltage The maximal motor voltage is 270V to 600V, depending on supply voltage and converter type (2-Q or 4-Q).
DC motor current According rated current of frame sizes from 20A to 1000A.
DC field voltage Max. field voltage 50V to 400V, depending on supply voltage, and a min. field voltage of 50V.
DC field current Maximal field current according to frame sizes from 4A to 20A.
More data ABB DCS400 Manual (7,6MB)


Tools

DCS400 Panel
DCS400PAN is the removable control and display panel with plain text display for:


Guided commissioning


Parameter programming


Fault detection


Reference and feedback display


Local operation


Parameter uploading (saving) and downloading (e.g. to a further DCS400)


Supported languages: English, German, French, Italian, Spanish
Start-up and Maintenance Program
The PC program Drive Window Light is the start-up and maintenance program for MS Windows(R) environments. The PC is to be connected via the serial port to DCS400 by using a standard serial cable. The Drive Window light has the following features available:


Parameter programming


Fault detection


Feedback display and analysis


Fault logger


Local operation


Parameter uploading, saving as file and downloading.


Monitoring


Accessories

Serial communication
In age of serial communication almost all PLCs supports one or more of open fieldbus systems. DCS400 can also be connected to serveral fieldbus systems by using a fieldbus specific adapter. Up to 6 datawords, like control word, status word, speed reference and speed feedback, can be transmitted in each direction: PLC <-> DCS400. According the fieldbus system also parameters can be read and written.

The documentation furcates in three parts: Fieldbus Adapter with DC Drives as an information, Adapter specific documentation and the Drive specific documentation, which is here the DCS400 Manual. If available fieldbus specific files are also attached.


Fieldbus

Adapter

Further documentations

CANopen

NCAN-02

Fieldbus Adapter with DC Drives
CANopen Adapter Inst/Start-up Guide
ABB DCS400 Manual (7.8MB)

DeviceNet

NDNA-02

Fieldbus Adapter with DC Drives
DeviceNet Adapter Inst/Start-up Guide
ABB DCS400 Manual (7.8MB)
EDS Files of DC Drives

Modbus

NMBA-01

Fieldbus Adapter with DC Drives
Modbus Adapter Inst/Start-up Guide
ABB DCS400 Manual (7.8MB)

PROFIBUS

NPBA-12

Fieldbus Adapter with DC Drives
PROFIBUS Adapter Inst/Start-up Guide
ABB DCS400 Manual (7.8MB)
GSD file of NPBA-12

 

ABB DCS400 Series

ABB Drive

Contact us for more information on products and prices.

ABB
DCS400 Module
Converter Type DC I DC II DC III  DC IV IF(A) Code Item
100% 100% 150% 100% 150% 100% 200% 100%
DCS401.0020 20 16 24 15 23 14 28 4 3ABD00007734
DCS401.0045 45 35 53 34 51 31 62 6 3ABD00007735
DCS401.0065 65 52 78 51 76 47 94 6 3ABD00007736
DCS401.0090 90 70 105 68 102 63 126 6 3ABD00007737
DCS401.0125 125 98 147 95 142 87 174 6 3ABD00007738
DCS401.0180 180 141 212 136 204 126 252 16 3ABD00007739
DCS401.0230 230 178 267 174 261 161 322 16 3ABD00007740
DCS401.0315 315 240 360 233 350 210 420 16 3ABD00007741
DCS401.0405 405 317 476 306 459 283 566 16 3ABD00007742
DCS401.0500 500 390 585 378 567 350 700 16 3ABD00007743
DCS401.0610 610 477 715 462 693 427 854 20 3ABD00007744
DCS401.0740 740 578 867 560 840 517 1034 20 3ABD00007745
DCS401.0900 900 700 1050 670 1005 620 1240 20 3ABD00008708
DCS402 4-quadrant converter Enclousure: IP00
DCS402.0025 25 24 36 23 35 24 48 4 3ABD00007746
DCS402.0050 50 44 66 42 63 40 80 6 3ABD00007747
DCS402.0075 75 60 90 56 84 56 112 6 3ABD00007748
DCS402.0100 100 71 107 69 104 68 136 6 3ABD00007749
DCS402.0140 140 106 159 101 152 101 202 6 3ABD00007750
DCS402.0200 200 149 224 146 219 124 248 16 3ABD00007751
DCS402.0260 260 203 305 197 295 182 364 16 3ABD00007752
DCS402.0350 350 267 401 258 387 233 466 16 3ABD00007753
DCS402.0450 450 352 528 340 510 315 630 16 3ABD00007754
DCS402.0550 550 430 645 416 624 385 770 16 3ABD00007755
DCS402.0680 680 531 797 515 773 475 950 20 3ABD00007756
DCS402.0820 820 641 961 621 932 573 1146 20 3ABD00007757
DCS402.1000 1000 766 1149 736 1104 675 1350 20 3ABD00008709
Line Reactor
Converter Type A/uH
DCS401.0020 DCS402.0025 ND01 18 / 512
DCS401.0045 DCS402.0050 ND02 37 / 250
DCS401.0065 DCS402.0075 ND04 55 / 168
DCS401.0090 DCS402.0100 ND05 82 / 135
DCS401.0125 DCS402.0140 ND06 102 / 90
DCS401.0180 DCS402.0200 ND07 184 / 50
DCS401.0230 DCS402.0260 ND07 184 / 50
DCS401.0315 DCS402.0350 ND09 245 / 37.5
DCS401.0405 DCS402.0450 ND10 367 / 25
DCS401.0500 DCS402.0550 ND10 367 / 25
DCS401.0610 DCS402.0680 ND12 490 / 18.8
DCS401.0900 DCS402.1000 ND13 698 / 18.2
EMC filter for main thyristor bridge DCS400(3x230V-500V AC)
Converter Type EMC Filter
230V~440V
DCS401.0020 DCS402.0025 NF3-440-25
DCS401.0045 DCS402.0050 NF3-440-50
DCS401.0065 NF3-440-64
DCS401.0090 DCS402.0100 NF3-440-80
DCS401.0125 DCS402.0140 NF3-440-110
230V~500V
DCS401.0020 DCS402.0025 NF3-500-25
DCS401.0045 DCS402.0050 NF3-500-50
DCS401.0065 NF3-500-64
DCS401.0090 DCS402.0100 NF3-500-80
DCS401.0125 DCS402.0140 NF3-500-110
DCS401.0180 DCS402.0200 NF3-500-320
DCS401.0230 DCS402.0260 NF3-500-320
DCS401.0315 DCS402.0350 NF3-500-320
DCS401.0405 DCS402.0450 NF3-500-600
DCS401.0500 DCS402.0550 NF3-500-600
DCS401.0610 DCS402.0680 NF3-500-600
DCS401.0740 DCS402.0820 NF3-690-1000
DCS401.0900 DCS402.1000 NF3-690-1000