Where the PSTB840-600-70 fits
The order code PSTB840-600-70 refers to an industrial module in the ABB range, supplied here as a tested spare. For built-in bypass contactor, the published value for PSTB840-600-70 is Model AF750, AC-3 Rated 750 A. The documented short time overload capability is 4×Ie for 10s (Heavy Duty Standard Startup Curve) on PSTB840-600-70. Rated continuous current (inline external connection) is recorded as 840 A (Long-term Full Load Operating Current). Order-code suffixes on the ABB SoftStart 840 A often describe variants that the control circuit terminal tightening torque entry alone cannot confirm.
Published ratings for ABB
The table quotes 1455 A (For Optimized Installation in Motor Delta Winding Circuit) against rated current (delta internal connection). Under main circuit rated voltage the table states 208–600 V AC 3-Phase, 50/60 Hz (IEC Marked Ue 500V. The control supply voltage value on the label is 100–250 V AC, 50/60 Hz (For Operator Panel and Main Control Board). Rated motor power compatibility (400v, inline) is recorded as 450 kW (Standard Operating Condition). Service notes from the previous changeover of the ABB SoftStart 840 A usually confirm the installation method entry. Under rated motor power compatibility (500v, inline) the table states 600 kW (Medium Voltage Operating Condition). Rated motor power compatibility (600v, inline) is recorded as 720 kW (High Voltage Operating Condition). The published figure for initial start voltage is 10% ~ 99% Ue (Factory Default: 30% Ue). The short time overload capability entry is best compared side by side with the old unit before the ABB SoftStart 840 A is fitted.
Cabinet checks before commissioning
Abb material code is recorded as 1SFA894019R7000 (Standard Unit). Standard communication is recorded as Built-in Modbus RTU (RS485) (Standard, No Additional Options Required). Matching the original mounting hardware avoids improvised brackets around the ABB SoftStart 840 A. PSTB840-600-70 is checked, cleaned and confirmed functional before shipping under a 12 month warranty.
| Parameter | Value |
|---|---|
| Parameter | Specification |
| ABB Material Code | 1SFA894019R7000 (Standard Unit); 1SFA894019R7020 (Conformal Coated Version, PSTB840-600-70T) |
| Product Type | PSTB Series Built-in Bypass Intelligent Soft Starter |
| Country of Origin | Västerås, Sweden (ABB Control Products SE-72161) |
| Applicable Standards | IEC 60947-4-2, UL 508; Compliant with CCC, CE, UKCA, RoHS |
| Rated Continuous Current (Inline External Connection) | 840 A (Long-term Full Load Operating Current) |
| Rated Current (Delta Internal Connection) | 1455 A (For Optimized Installation in Motor Delta Winding Circuit) |
| Main Circuit Rated Voltage | 208–600 V AC 3-Phase, 50/60Hz (IEC Marked Ue 500V; UL Marked Ue 600V) |
| Control Supply Voltage | 100–250 V AC, 50/60Hz (For Operator Panel and Main Control Board) |
| Rated Motor Power Compatibility (400V, Inline) | 450 kW (Standard Operating Condition) |
| Rated Motor Power Compatibility (500V, Inline) | 600 kW (Medium Voltage Operating Condition) |
| Rated Motor Power Compatibility (600V, Inline) | 720 kW (High Voltage Operating Condition) |
| Built-in Bypass Contactor | Model AF750, AC-3 Rated 750A; Automatically Bypasses Thyristors After Startup to Reduce Standby Loss |
| Short Time Overload Capability | 4×Ie for 10s (Heavy Duty Standard Startup Curve) |
| Initial Start Voltage | 10% ~ 99% Ue (Factory Default: 30% Ue) |
| Soft Start Ramp Time | 0.5 ~ 120 s (Factory Default: 10 s) |
| Soft Stop Ramp Time | 0.5 ~ 120 s (Factory Default: 10 s) |
| Current Limit Multiplier for Startup | 1.5 ~ 7 × Ie (Factory Default: 3 × Ie) |
| Kick Start Voltage | 0 ~ 30% Ue Short-term Boost (Factory Default: Disabled, For Heavy Duty Locked Rotor Loads) |
| Pump Torque Control (Water Hammer Prevention) | 0 ~ 100% Torque Continuously Adjustable (Factory Default: Disabled) |
| Jog Mode | 0 ~ 30% Constant Torque Low Speed Output (Factory Default: Disabled) |
| Electronic Overload Protection | Class 10A/10/20/30 Selectable Thermal Trip Curve (Integrated EOL Protection) |
| Overcurrent/Short Circuit Protection | Current Limit Lock + Instantaneous Trip (Real-time 3-Phase Current Monitoring) |
| Phase Loss/Phase Unbalance Protection | Alarm and Shutdown When Phase Current Difference > 30% (Real-time 3-Phase Current Detection) |
| Thyristor Heatsink Overheat Protection | Derating at >85℃, Fault Shutdown at >105℃ (Built-in Temperature Sensor) |
| Bypass Contactor Fault Detection | Contact Adhesion/Open Circuit Monitoring and Alarm (Bypass Circuit Self-check) |
| Motor PTC Thermistor Protection | Supports External Motor Winding Temperature Probe (Standard Integrated Interface) |
| Motor Underload Protection | Customizable Underload Current Threshold (For Pump Dry Run Detection) |
| Locked Rotor Protection | Fault Alarm for Long-term High Current Lock (Suitable for Conveyor, Crusher Loads) |
| Control Supply Under-Voltage/Loss Protection | Warning at Us <85V, Main Circuit Disconnection at Complete Power Loss (Continuous Control Loop Monitoring) |
| Digital Inputs (DI) | 6 Channels of Passive Dry Contacts (Start, Stop, Reset, External Fault, Jog, Spare) |
| Programmable Relay Outputs (DO) | 3 Channels of Normally Open Contacts, AC250V 8A Capacity (Running, Bypass Closed, General Fault Signals) |
| Analog Output | 4–20mA/0–10V Selectable (Real-time Output of Motor Operating Current) |
| Standard Communication | Built-in Modbus RTU (RS485) (Standard, No Additional Options Required) |
| Optional Communication Modules | Profibus DP, DeviceNet, CANopen, Modbus TCP (Separate FieldBusPlug Option Required) |
| Operator Panel | Standard Backlit Multi-language LCD Local Panel (Fault Code, Real-time Parameter Display; Optional IP66 Remote Handheld Panel) |
| Operating Ambient Temperature | 0℃ ~ +40℃ for Full Load 840A; Derating Required for 40~50℃ (Full Operating Range 0~50℃) |
| Storage/Transport Temperature | -25℃ ~ +70℃ (ABB Factory Standard for Warehousing and Transportation) |
| Relative Humidity | 5%–95%RH, No Condensation, No Corrosive Gases (Non-condensing Environment) |
| Altitude Derating Standard | For Altitude >1000m, Rated Current Derates 0.5% for Every 100m Increase (Mandatory Derating for High Altitude Installation) |
| Cooling Method | Built-in Forced Air Cooling Fan (Fan Fault with Built-in Alarm Function) |
| Protection Rating | Main Unit IP00; IP20 with Optional Cabinet Protection Cover (Only for Installation in Control Cabinet) |
| Main Circuit Terminal Tightening Torque | 45 N·m |
| Control Circuit Terminal Tightening Torque | 0.5 N·m |
| Installation Method | Vertical Wall Mounting, Inverted/Horizontal Flat Installation Prohibited |
| Optional Accessories | IP20 Cabinet Dust Protection Kit, dv/dt Output Reactor, PTC Motor Temperature Measurement Module, Remote Operator Panel Extension Kit, Communication Bus Adapter |
| Certifications | CE, CCC, UKCA, UL US (All Marked on Nameplate) |
| Manufacturer | ABB |
| Manufacturer Part Number | PSTB840-600-70 |
| Product Series | ABB |
| Supply Voltage | Not available |
| Net Weight | Not available |
| Dimensions | Not available |
| Condition | Tested and cleaned, in good working order |
| Warranty | 12 month warranty |