Allen Bradley panelview 550 Terminals

The PanelView Standard 550 Graphic Terminals have a 5.5 in. monochrome flat-panel display with 256 x 128 resolution. The touch screen version of the PanelView 550 terminal is available only with 24V DC power. These terminals support operator input via keypad, via touch screen or via keypad with touch screen.

Technical Specifications

  • Display Options:Color
    • Monochrome
    • Grayscale
    • 3 – 10inch display
  • Communication Options:
    • Point-to-point
    • Network
    • EtherNet/IP
  • Includes screen security and ATA PC memory card
Panelview 550 Description Stock Level
2711-B5A1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-B5A10 DeviceNet Communication and RS-232 Printer Port
In Stock
2711-B5A10L1 DeviceNet Communication and RS-232 Printer Port and 24VDC
In Stock
2711-B5A12L1 KEYPAD,TOUCHSCREEN MONO,5.5IN DISPLAY
Call
2711-B5A14L1 KEYPAD,TOUCHSCREEN MONO,5.5IN DISPLAY
Call
2711-B5A15 ControlNet Communication and RS-232 Printer Port
In Stock
2711-B5A15L1 ControlNet Communication and RS-232 Printer Port
Available Now
2711-B5A16 RS-232 (DF1) Communication and RS-232 Printer/Download Port
In Stock
2711-B5A16L1 RS-232 (DF1) Communication and RS-232 Printer/Download Port
Available Now
2711-B5A1L1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-B5A2 DH-485 Communication Ports
In Stock
2711-B5A20 EtherNet/IP Communication and RS-232 Printer Port
Available Now
2711-B5A20L1 EtherNet/IP Communication and RS-232 Printer Port
Available Now
2711-B5A2L1 DH-485 Communication Ports
Available Now
2711-B5A3 DH-485 Communication and RS-232 Printer Port
In Stock
2711-B5A3L1 DH-485 Communication and RS-232 Printer Port
In Stock
2711-B5A5 RS-232 (DH-485) Communication Port
In Stock
2711-B5A5L1 RS-232 (DH-485) Communication Port
Available Now
2711-B5A8 DH+ Communication and RS-232 Printer Port
In Stock
2711-B5A8L1 DH+ Communication and RS-232 Printer Port
In Stock
2711-B5A9 RS-232 (DH-485) Communication and RS-232 Printer Port
Available Now
2711-B5A9L1 RS-232 (DH-485) Communication and RS-232 Printer Port
Call
2711-K5A1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-K5A10 DeviceNet Communication and RS-232 Printer Port
In Stock
2711-K5A10L1 PANELVIEW STANDARD TERMINAL
Available Now
Panelview 550 Description Stock Level
2711-B5A1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-B5A10 DeviceNet Communication and RS-232 Printer Port
In Stock
2711-B5A10L1 DeviceNet Communication and RS-232 Printer Port and 24VDC
In Stock
2711-B5A12L1 KEYPAD,TOUCHSCREEN MONO,5.5IN DISPLAY
Call
2711-B5A14L1 KEYPAD,TOUCHSCREEN MONO,5.5IN DISPLAY
Call
2711-B5A15 ControlNet Communication and RS-232 Printer Port
In Stock
2711-B5A15L1 ControlNet Communication and RS-232 Printer Port
Available Now
2711-B5A16 RS-232 (DF1) Communication and RS-232 Printer/Download Port
In Stock
2711-B5A16L1 RS-232 (DF1) Communication and RS-232 Printer/Download Port
Available Now
2711-B5A1L1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-B5A2 DH-485 Communication Ports
In Stock
2711-B5A20 EtherNet/IP Communication and RS-232 Printer Port
Available Now
2711-B5A20L1 EtherNet/IP Communication and RS-232 Printer Port
Available Now
2711-B5A2L1 DH-485 Communication Ports
Available Now
2711-B5A3 DH-485 Communication and RS-232 Printer Port
In Stock
2711-B5A3L1 DH-485 Communication and RS-232 Printer Port
In Stock
2711-B5A5 RS-232 (DH-485) Communication Port
In Stock
2711-B5A5L1 RS-232 (DH-485) Communication Port
Available Now
2711-B5A8 DH+ Communication and RS-232 Printer Port
In Stock
2711-B5A8L1 DH+ Communication and RS-232 Printer Port
In Stock
2711-B5A9 RS-232 (DH-485) Communication and RS-232 Printer Port
Available Now
2711-B5A9L1 RS-232 (DH-485) Communication and RS-232 Printer Port
Call
2711-K5A1 Remote I/O Communication and RS-232 Printer Port
In Stock
2711-K5A10 DeviceNet Communication and RS-232 Printer Port
In Stock
2711-K5A10L1 PANELVIEW STANDARD TERMINAL
Available Now

Troubleshooting Your PanelView 550

PanelView 550 Startup Failure

If your PanelView 550 fails to startup properly, always check the power supply first. Ensure the terminal is receiving the correct voltage and that the wiring and connections to the power source are valid. In addition, you should also ensure the DC power positive and negative are attached to the proper terminals.

PanelView 550 Status Indicators

The status indicators are located on the back of your PanelView 550 terminal.  The COMM indicator is green and reflects communication. The FAULT indicator is red and reflects hardware faults. Upon startup, the fault indicator should be off and the comm indicator on. If the fault indicator flashes a few times at startup, this is not a concern. However, if both indicators are off you should check the power cable. See the table below to interpret the terminal’s indicator status:

Status Indicators – DH+, DH-485, DF1

Indicator Status Meaning
Comm On Normal Operation
Off Fault Present-

Ensure controller is in run mode. Check baud settings of controller/terminal. Check for proper controller connections.

Blinking Failed to establish communication
Fault On Fault Present –

Restart terminal. If the error persists, the terminal requires servicing. Click here for information about DO Supply’s repair service.

Off Normal Operation
Blinking No applications loaded/application is corrupt. Reload the application.

tatus Indicators – Ethernet/IP, ControlNet, DeviceNet Networks

Indicator Status Meaning
Comm On Normal operation
Off Hardware failure
Blinking Failed to establish communication
Fault On Hardware failure.
Off Normal operation
Blinking Application not loaded/application is corrupt

Status Indicators – Remote I/O

Indicator Status Meaning
Comm On Normal operation
Off Communication non-functional
Blinking Failed to establish communication, PLC may be in program mode
Fault On Fault Present –

Check baud rate and rack settings. Ensure proper connections from terminal to controller. Verify remote I/O is enabled.

Off Normal Operation
Blinking Application not loaded/application is corrupt

PanelView 550 Application Issues

Application Issues

Issue Possible Cause Action
Failed Application Download (Initial Attempt) Disconnected Communication Cable Check cable type and connection
Improper Computer COM Port Selection Ensure you have the correct COM port number in PanelBuilder32 or WinPFT software
Communication Settings/Rate Incorrect Ensure computer and terminal share the same communication settings
Failed Application  Download (Subsequent Attempts) Communication Settings/Rate Incorrect Ensure computer and terminal share the same communication settings. Adjust settings in the Communication Setup screen
Application File Name Appears as ******* Invalid Application Redownload application
Unusable Application Due to Error Download new application
Failed Application Transfer from Memory Card Memory card incorrectly installed Reinstall, verify its installed correctly
Application to Large for Terminal Memory Reduce application size
Incorrect Data Checksum Ensure memory card is properly seated. It is possible the application may be corrupt
File Format Invalid Verify file format (.PVA)
Failed Application Transfer to Memory Card Memory card incorrectly installed Reinstall, verify its installed correctly
Memory Card May be Wire Protected Change memory card protection switch
Another File on the Memory Card Erase/reformat card
Application to Large Reduce application size, erase/reformat card
Memory Card Format Invalid Replace/reformat card
Incorrect Data Checksum Ensure card is installed correctly
Application Does Not Exist Ensure application exists

Allen Bradley panelview

Product manuals

# File Description Date added File size Downloads
1 pdf Allen Bradley Panelview 550 Terminals Allen Bradley panelview 550 Terminals
Allen Bradley panelview 550 Terminals
08/31/2017 11:52 858 KB 156