When a SLC 100 or 150 panel runs out of input terminals, the answer is another housing on the same bus, not a new controller. The 1745-E151 is that expansion unit: 20 external I/O input circuits, 85 to 132 VAC at 50 or 60 Hz, current sinking. It mounts on the 1745 chassis or on the expansion unit housing, so the existing layout, addresses and drawings carry over with the hardware. Nothing in the unit is configurable, which is an advantage on a panel nobody wants to revisit.
- Twenty external input circuits per unit, added to the count already wired in the panel, with no program change needed to see them.
- Supply of 85 to 132 VAC at 50 or 60 Hz, with current sinking input circuits that match the sensors already on the machine.
- Fits the 1745 chassis or the expansion unit housing, with CE and cULus certification and terminal numbering that follows the host chassis. That keeps the drawing valid.
This is input expansion, so it adds no outputs and no analog channels; where the shortage is on the output side, the unit does not help. Plan for 120 V only. Current sinking inputs expect the field device to supply the positive side. The 85 to 132 VAC window is a 120 V class figure, not a 240 V one, so check the panel supply before ordering. Dimensions are not published here, so measure the existing housing first. Check the leakage current of any two-wire sensor, since a sinking input can hold on through it.
Ambient range is 0 to 60 degrees Celsius and storage -40 to 85 degrees Celsius. Reserve the new terminal numbers in the PLC file before power-up, so the circuits are documented from day one, not after the first fault. The unit ships assembled, so no configuration step sits between the carton and the terminal strip. Certified to CE and cULus. Testing comes first; the 12 month warranty follows the shipment.
| Catalog number | 1745-E151 |
| Manufacturer | Allen-Bradley |
| Product family | SLC 100 / 150 (1745) |
| Product type | PLC Module |
| Description | EXPANSION UNIT, FOR PROGRAMMABLE CONTROLLER, 20 EXTERNAL I/O INPUT CIRCUITS, 85-132 VAC, 50/60 HZ, CURRENT SINKING |
| Condition | Tested and cleaned, in good working order |
| Warranty | 12 months |
| Place of origin | Made in USA |
| Stock status | In stock |
| Supply voltage | Not available |
| Current rating | Not available |
| Communication interface | Not available |
| Number of slots | Not available |
| Dimensions (W x H x D) | Not available |
| Mounting | 1745 chassis or expansion unit housing |
| Operating temperature | 0 to 60 °C (32 to 140 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Certifications | CE, cULus |