The 1746-HS is the IMC 110 motion control system card for SLC 500 racks. It runs on 24 volt DC inputs and outputs with a 104 mA draw on the 24 V backplane supply, and it brings point-to-point motion under the SLC processor’s command.
Motion inside the SLC rack
Machines that need indexed positioning but not a full servo system, such as stopper-and-dwell transfers, pick positions on gantries, or feed-to-length duties, were commonly built around the IMC 110 class. The card handles the position loop while the SLC program decides when to move and when to stop, so machine logic and motion live in one controller and one programming environment rather than split across two systems that drift apart over years.
Key specifications
| Manufacturer | Allen-Bradley |
| Product family | SLC 500 (1746/1747) |
| Product type | PLC Module |
| Product Code | 1746-HS |
| Inputs | 24 V DC |
| Outputs | 24 V DC |
| Backplane Current (24 V DC) | 104 mA |
| Place of Origin | Made in USA |
| Axes Supported | Not available |
| Net weight | Not available |
| Mounting | 1746 chassis (4, 7, 10, 13 or 16 slot) |
| Backplane supply | SLC 500 parallel backplane |
| Enclosure rating | Open style, IP20 |
| Operating temperature | 0 to 60 °C (32 to 140 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Relative humidity | 5 to 95%, non-condensing |
| Certifications | CE, cULus |
| Condition | Tested and cleaned, in good working order |
| Warranty | 12 months |
| Stock status | In stock |
Motion card health checks
IMC 110 duties degrade gradually: homing takes longer, positioning overshoots slightly, and the first symptom is usually operator complaints about cycle time rather than an alarm. Check the 24 V supply quality at the chassis first, since motion cards draw from that rail and a sagging supply imitates servo faults. Inspect encoder cables for the flex damage that comes from years of machine movement, and verify travel limit switches independently of the motion program before any powered move after maintenance. Keep the motion parameters documented alongside the ladder, because a replacement card needs both restored, and machines built on this platform often have no one left who remembers the original tuning.
Service notes
Check the 24 V backplane budget in your chassis before slotting it, because motion cards draw from the 24 V rail and smaller power supplies feel it. Verify homing sensors and travel limits independently before the first powered move, and keep encoder and command wiring separated from drive power inside the cabinet. Machines still running this card are usually older SLC builds kept alive for a reason, so a tested spare is worth shelf space.