The 1746-INT4 reads four thermocouple or millivolt signals into an SLC 500 rack, with each of the four inputs isolated from the others. A 110 mA draw on the 5 V backplane and an 8 Hz bandwidth put it in the slow-process category, which is exactly where thermocouples live.
Why per-channel isolation matters
Thermocouples sit on hot metal, and hot metal is rarely at a tidy ground potential. On a non-isolated card, one grounded junction can shift every reading on the module by tens of degrees. The INT4 isolates each channel, so a grounded junction on the oven wall only affects that one point. Four isolated channels per slot also suits mixed sensing, for example two oven zones and two bearing probes on the same card.
Key specifications
| Manufacturer | Allen-Bradley |
| Product family | SLC 500 (1746/1747) |
| Product type | PLC Module |
| Product Code | 1746-INT4 |
| Inputs | 4 (isolated) |
| Backplane Current (5 V DC) | 110 mA |
| Bandwidth | 8 Hz |
| Place of Origin | Made in USA |
| Thermocouple Types | Not available |
| Resolution | Not available |
| Mounting | 1746 chassis (4, 7, 10, 13 or 16 slot) |
| Backplane supply | SLC 500 parallel backplane |
| Enclosure rating | Open style, IP20 |
| Operating temperature | 0 to 60 °C (32 to 140 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Relative humidity | 5 to 95%, non-condensing |
| Certifications | CE, cULus |
| Condition | Tested and cleaned, in good working order |
| Warranty | 12 months |
| Stock status | In stock |
Multi-zone thermal wiring done right
Plan the thermocouple runs as a set: same cable type throughout, same routing, and a common ground reference point for shields. Channel isolation lets you mix J and K probes on one card, which is practical on ovens whose zones were upgraded at different times, but each channel’s configured type must match its probe, so keep a wiring table with both facts on one line. Compensated extension cable must run all the way to the panel; copper tail wire inside the last meter undoes the whole benefit. After commissioning, log one steady-state comparison against a handheld probe per zone, so future drift has a baseline to be judged against.
Commissioning checks
Configure each channel for its thermocouple type in the module setup and match the type to what is actually bolted to the machine; a J wired where the program expects a K reads wrong by a large margin. Use compensated extension cable all the way to the terminal, and keep TC wiring away from drive output cables. Confirm cold-junction behavior by comparing one channel against a handheld probe at steady temperature before trusting the loop.