A 400 volt class drive for a small axis is the role of the 2198-E4004-ERS. It is a Kinetix 5100 servo drive delivering 0.4 Kilowatts of output power, with output current of 1.6 Amps continuous and peak output current of 5.4 Amps. The input voltage range is 342 to 528 Volts AC, so the same unit rides both a 400 volt and a 480 volt bus without a transformer change. Control is integrated motion over EtherNet/IP (CIP Motion) on the plant network, so the axis is commissioned without extra motion hardware.
Input range across 400 and 480 volt buses
Cooling is by natural convection with vertical mounting as the listed orientation, so there is no fan to clog in a dusty cabinet and the vents have to stay clear for the airflow path to work. The enclosure rating is Open style, IP20, putting the drive inside an enclosure where the cabinet provides the protection. Spacing around the unit should follow the cabinet layout rather than the machine frame, since convection needs free air above and below the drive body.
Natural convection and vertical mounting
The sizing conversation at this rating is the overload window: 5.4 Amps peak against 1.6 Amps continuous leaves room for a fast index move but not for a high-inertia roll running near its limit for long stretches. Operating temperature spans 0 to 50 °C (32 to 122 °F) and storage spans -40 to 85 °C (-40 to 185 °F). Certifications are CE and cULus, and the input range of 342 to 528 Volts AC covers the standard industrial three-phase bands.
Overload window and temperature limits
For replacement, keep the vertical orientation and the convection clearances noted above, and confirm the fitted motor’s continuous demand sits inside the 1.6 Amps rating. The unit is offered as Tested and cleaned, in good working order.Each display passes a functional check before dispatch, backed by a 12 month warranty.
| Catalog number | 2198-E4004-ERS |
| Manufacturer | Allen-Bradley |
| Product family | Kinetix servo drive |
| Product type | AC Drive |
| Mounting Orientation | Vertical |
| Cooling | Natural Convection |
| Output Power | 0.4 Kilowatts |
| Input Voltage | 342 to 528 Volts AC |
| Output Current | 1.6 Amps |
| Peak Output Current | 5.4 Amps |
| Control | Integrated motion over EtherNet/IP (CIP Motion) |
| Enclosure rating | Open style, IP20 |
| Operating temperature | 0 to 50 °C (32 to 122 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Certifications | CE, cULus |
| Condition | Tested and cleaned, in good working order |
| Warranty | 12 months |
| Place of origin | Made in USA |
| Stock status | In stock |