Allen-Bradley Allen-Bradley – PanelView Plus 600

The PanelView Standard 600 Operator Interface Terminals have a 5 inch color flat-panel display with 320 x 234 resolution. The PanelView 600 terminal is designed for safe use when installed in a suitably rated NEMA Type 12, 13, 4X, IP54 or IP65 enclosure. These terminals support operator input via keypad, via touch screen or via keypad with touch screen.

PanelView Plus 600
Part number Manufacturer Description
2711P-T6C20D Allen Bradley PanelView Plus 600 Color Touch Ethernet Dc Ps Incl Rs232 & Usb 32Mb Flash/64Mb Ram
2711P-T6M20D Allen Bradley PanelView Plus 600 Grayscale Touch Ethernet Dc Ps Incl Rs232 & Usb 32Mb Flash/64Mb Ram
2711PRFK6 Allen Bradley Replacement Function Key Legend Strips For PanelView Plus 600 Incl Printable Blank Legends & Sw
2711PRGK6 Allen Bradley Protective Antiglare Overlay Qty 3 For PanelView Plus 600 Keypad Or Key/Touch
2711PRAK6 Allen Bradley Cutout Adapter To Mount PanelView Plus 600 Keypad In PanelView 600 Keypad Cutout
2711PRGT6 Allen Bradley Protective Antiglare Overlay Qty 3 For PanelView Plus 600 Touch
2711PT6C20A Allen Bradley PanelView Plus 600 Color Touch Ethernet Ac Ps Incl Rs232 & Usb 32Mb Flash/64Mb Ram
2711PB6C3D Allen Bradley PanelView Plus 600 Color Key/Touch Dh485 Dc Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PB6C5D Allen Bradley PanelView Plus 600 Color Key/Touch Rs232 Dc Ps Incl Usb 32Mb Flash/64Mb Ram
2711PT6C8D Allen Bradley PanelView Plus 600 Color Touch Dh+ Dc Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PK6C5D Allen Bradley PanelView Plus 600 Color Keypad Rs232 Dc Ps Incl Usb 32Mb Flash/64Mb Ram
2711PST6BM Allen Bradley PanelView Plus 600 Grayscale Key/Touch Starter Kit Incl 2711P-B6M20A 2711-Nc13 & 9701-Vwstmene
2711PST6BC Allen Bradley PanelView Plus 600 Color Key/Touch Starter Kit Incl 2711P-B6C20A 2711-Nc13 & 9701-Vwstmene
2711PST6KC Allen Bradley PanelView Plus 600 Color Keypad Starter Kit Incl 2711P-K6C20A 2711-Nc13 & 9701-Vwstmene
2711PRN1 Allen Bradley Srio Network Communication Module For PanelView Plus 400 & 600
2711PT6M8D Allen Bradley PanelView Plus 600 Grayscale Touch Dh+ Dc Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PK6M8D Allen Bradley PanelView Plus 600 Grayscale Keypad Dh+ Dc Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PK6M8A Allen Bradley PanelView Plus 600 Grayscale Keypad Dh+ Ac Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PK6M5D Allen Bradley PanelView Plus 600 Grayscale Keypad Rs232 Dc Ps Incl Usb 32Mb Flash/64Mb Ram
2711PK6M5A Allen Bradley PanelView Plus 600 Grayscale Keypad Rs232 Ac Ps Incl Usb 32Mb Flash/64Mb Ram
2711PK6M3D Allen Bradley PanelView Plus 600 Grayscale Keypad Dh485 Dc Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PST6KM Allen Bradley PanelView Plus 600 Grayscale Keypad Starter Kit Incl 2711P-K6M20A 2711-Nc13 & 9701-Vwstmene
2711PST6TC Allen Bradley PanelView Plus 600 Color Touch Starter Kit Incl 2711P-T6C20A 2711-Nc13 & 9701-Vwstmene
2711PT6M8A Allen Bradley PanelView Plus 600 Grayscale Touch Dh+ Ac Ps Incl Rs232 Ethernet & Usb 32Mb Flash/64Mb Ram
2711PT6M5A Allen Bradley PanelView Plus 600 Grayscale Touch Rs232 Ac Ps Incl Usb 32Mb Flash/64Mb Ram

Our Main Business on :PanelView Plus 6,PanelView Plus 400,PanelView Plus 600,PanelView Plus 700 ,PanelView Plus 1000,PanelView Plus 1500 ,PanelView Plus 1250…All the ALLEN BRADLEY AC Drives we sell Made in America! 100% Original!

Allen-Bradley PanelView 600 Technical Specifications

Troubleshooting

Troubleshooting Your PanelView 600

PanelView 600 Startup Failure

If your PanelView 600 fails to startup properly, always check the power supply first. Ensure the terminal is receiving the correct voltage and that the wiring and connections to the power source are valid. In addition, you should also ensure the DC power positive and negative are attached to the proper terminals.

PanelView 600 Status Indicators

The status indicators are located on the back of your PanelView 600 terminal.  The COMM indicator is green and reflects communication. The FAULT indicator is red and reflects hardware faults. Upon startup, the fault indicator should be off and the comm indicator on. If the fault indicator flashes a few times at startup, this is not a concern. However, if both indicators are off you should check the power cable. See the table below to interpret the terminal’s indicator status:

Status Indicators – DH+, DH-485, DF1

Indicator Status Meaning
Comm On Normal Operation
Off Fault Present-

Ensure controller is in run mode. Check baud settings of controller/terminal. Check for proper controller connections.

Blinking Failed to establish communication
Fault On Fault Present –

Restart terminal. If the error persists, the terminal requires servicing. Click here for information about DO Supply’s repair service.

Off Normal Operation
Blinking No applications loaded/application is corrupt. Reload the application.

Status Indicators – Ethernet/IP, ControlNet, DeviceNet Networks

Indicator Status Meaning
Comm On Normal operation
Off Hardware failure
Blinking Failed to establish communication
Fault On Hardware failure.
Off Normal operation
Blinking Application not loaded/application is corrupt

Status Indicators – Remote I/O

Indicator Status Meaning
Comm On Normal operation
Off Communication non-functional
Blinking Failed to establish communication, PLC may be in program mode
Fault On Fault Present –

Check baud rate and rack settings. Ensure proper connections from terminal to controller. Verify remote I/O is enabled.

Off Normal Operation
Blinking Application not loaded/application is corrupt

PanelView 600 Application Issues

Application Issues

Issue Possible Cause Action
Failed Application Download (Initial Attempt) Disconnected Communication Cable Check cable type and connection
Improper Computer COM Port Selection Ensure you have the correct COM port number in PanelBuilder32 or WinPFT software
Communication Settings/Rate Incorrect Ensure computer and terminal share the same communication settings
Failed Application  Download (Subsequent Attempts) Communication Settings/Rate Incorrect Ensure computer and terminal share the same communication settings. Adjust settings in the Communication Setup screen
Application File Name Appears as ******* Invalid Application Redownload application
Unusable Application Due to Error Download new application
Failed Application Transfer from Memory Card Memory card incorrectly installed Reinstall, verify its installed correctly
Application to Large for Terminal Memory Reduce application size
Incorrect Data Checksum Ensure memory card is properly seated. It is possible the application may be corrupt
File Format Invalid Verify file format (.PVA)
Failed Application Transfer to Memory Card Memory card incorrectly installed Reinstall, verify its installed correctly
Memory Card May be Wire Protected Change memory card protection switch
Another File on the Memory Card Erase/reformat card
Application to Large Reduce application size, erase/reformat card
Memory Card Format Invalid Replace/reformat card
Incorrect Data Checksum Ensure card is installed correctly
Application Does Not Exist Ensure application exists
Technical Specifications
  • Display Options:
    • Color
    • Monochrome
    • Grayscale
    • 3 – 10inch display
  • Communication Options:
    • Point-to-point
    • Network
    • EtherNet/IP
  • Includes screen security and ATA PC memory card