Danfoss VLT 2800 Inverter HVAC Drives Inverter Drive

Danfoss VLT2800 Inverter Drives

The VLT 2800 series are among the smallest multi-purpose drives in the market, designed for space saving side-by-side mounting. Choose to have it with Motor Coils, RFI filter, LC+1B filters e.g. The VLT 2800 is designed as an advanced and versatile drive, yet easy to operate. Quick menu includes all basic parameters needed for commissioning the drive, offering fast installation and service.

An excellent price/performance have made the VLT 2800 a pace-setter within general purpose drives. In virtually any application, the VLT 2800 has proved trustworthy, robust, easy to operate and commision. A favourable price combined with reliability and a number of useful functionalities have made the VLT 2800 a pace-setter within general purpose drives.

Automatic Motor Tuning (AMT) measures the motor parameters to ensure optimal match between drive and motor thus increasing performance of your drive Application and saving commissioning time. The VLT 2800 complies with the EMC norm EN 55011 Class 1A and 1B (with RFI filter). The VLT 2800 will survive even short circuit of motor cables and short circuit of signal cables. The VLT 2800 will operate normally (no need for derating) in environment temperatures up to 45° C (24 hour average max. 40° C.)

Product Range

0.55 – 18.5 kW : (3 phase 380 – 480 V ± 10 %; 50/60 Hz)
0.37 – 1.5 kW : (Combined 1 and 3 phase 200 – 240 V ± 10 %; 50/60 Hz)
2.2 – 3.7 kW : (3 phase 200 – 240 V ± 10 %; 50/60 Hz)

Variable output frequency between 0 and 1000 Hz

Danfoss VLT 2800 Inverter HVAC Drives Inverter Drive

The Danfoss VLT® 2800 series are among the smallest multi-purpose drives in the market, designed for space saving side-by-side mounting. Choose to have it with Motor Coils, RFI filter, LC+1B filters.

The VLT® 2800 is designed as an advanced and versatile drive, yet easy to operate. Quick menu includes all basic parameters needed for commissioning the drive, offering fast installation and service.

Features

  • Robust die-cast chassis, good heat dissipation
  • Protected against main transients
  • Metasys for HVAC
  • Hot pluggable display including copy function as option
  • MCT-10
  • Precise stop
  • DC-coil built in for harmonics
  • Cold plate technology

VLT 2800 Drive

Power SizeAC Line VoltageHPOutput Amps
220-240V – Dual 1 or 3 Phase
VLT2803D20.52.2
VLT2805D20.753.2
VLT2807D214.2
VLT2811D21.56
VLT2815D226.8
VLT2822D239.6
VLT2840D2516
D2 – Unit cannot be ordered with RFI filter
220-240V 1 phase
VLT2803S20.52.2
VLT2805S20.753.2
VLT2807S214.2
VLT2811S21.56
VLT2815S226.8
S2 – Unit can only be ordered with RFI filter
200-240V 3 phase
VLT2822T239.6
VLT2840T2516
380-480V 3 Phase
VLT2805T40.751.7
VLT2807T412.1
VLT2811T41.53
VLT2815T423.7
VLT2822T435.2
VLT2830T447
VLT2840T459.1
VLT2855T47.512
VLT2875T41016
VLT2880 – NEMA 1T41524
VLT2881 – NEMA 1T42032
VLT2882 – NEMA 1T42537.5

Accessories

Local Control Panel
175N0131LCP-2 keypad
175Z0850LCP remote mounting kit
175Z0929Cable only (10′)
NEMA 1 Kit
195N1900For VLT 2803-2815
195N1901For VLT 2822-2830; VLT 2840 (460V only)
195N1902For VLT 2840 (230V only); VLT 2855 and 2875
Add on modules
195N3100RFI B1/LC FilterFor VLT 2803-2805 (230V); VLT 2807-2815 (460V)
195N3101RFI B1/LC FilterFor VLT 2807-2822 (230V); VLT 2822-2840 (460V)
195N3103RFI B1 FilterFor VLT 2803-2840 (230V); VLT 2803-2875 (460V)
195N3110Motor CoilFor VLT 2803-2840 (230V); VLT 2803-2875 (460V)

Product manuals

#FileDescriptionDate addedFile sizeDownloads
1 pdf VLT2800操作指南 (1)09/30/2017 15:346 MB300