ROSEMOUNT 5300 SERIES – TEST and MEASUREMENT

Rosemount 5300 Series

 Industry leading measurement capability and reliability
 Safety certified to IEC 61508 for SIL2 applications
 Increased plant availability with predictive maintenance and easy troubleshooting
 Reduced instrument count and process penetrations with a multivariable transmitter

Rosemount 5300 Series

Do you want to find  Rosemount 5300 Series?Contact us now.

Special Rosemount 5300 Series features

Optimized to suit more applications
 Suitable for most liquid and solids level applications and liquid interface applications
 Handles even the most challenging applications reliably, including process vessels, control, and safety systems
 Easy retrofit in existing chambers or available as complete assembly with high quality Rosemount 9901 chambers
 Dynamic Vapor Compensation assures accuracy also in saturated steam

Best performance and uptime
 Unique Direct Switch Technology and Probe End Projection improve capability and reliability particularly in challenging applications
 Single lead probe for long measuring ranges, obstructions and low dielectrics ensures reliability in more applications, such as viscous media
 Smart Galvanic Interface results in a more stable microwave and EMI performance with minimized effects from outside disturbances

Robust design and increased safety
 Heavy-duty unique hardware for extreme temperature and pressures with multiple layers of protection
 EchoLogics and smart software functions provide enhanced ability to keep track of the surface and detect a full vessel situation
 Third party approved for overfill prevention and Safety Integrated System SIL3 suitability
 Electronics and cable connections in separate compartments provides safer handling and improved moisture protection
 Online device verification and reliable detection of high level conditions with the verification reflector

Easy installation and plant integration
 Easy upgrade by matching existing tank connections and cut-to-fit probes
 Long lengths of rigid probes for robust measurements become cost-effective and practical to ship, store and install with the segmented probe option (code 4S)
 Multivariable device reduces the number of process penetrations
 Seamless system integration with HART®, FOUNDATION™ Fieldbus, Modbus®, or IEC 62591 (WirelessHART®) with the Emerson™ Smart Wireless THUM™ Adapter
 Pre-configured or easy configuration in Rosemount Radar Master with a five-step wizard, auto connect, and online help
 Enhanced DD with step-by-step configuration and echo curve capability (HART) in tools such as AMS™ Device Manager, and Field Communicator
 DTM™ with echo curve capability for use in FDT®/DTM compatible configuration tools such as PACTware™, Yokogawa FieldMate/PRM
Minimized maintenance reduces cost
 Easy online troubleshooting with user friendly software, utilizing powerful echo curve and logging tools
 Signal Quality Metrics diagnostics detect product build-up on probe to monitor turbulence, boiling, foam, and emulsions
 Predictive maintenance with advanced diagnostics and PlantWeb™ alerts
 Modular design for reduced spare parts and easy replacement of the transmitter housing without opening the tank

SYSTEM ARCHITECTURE

The Rosemount 5300 Series Radar Transmitter is loop-powered which means it uses the same two wires for both power supply and output signal.
The output is a 4-20 mA analog signal superimposed with a digital HART signal or FOUNDATION Fieldbus.
By using the optional HART Tri-loop, it is possible to convert the HART signal to up to three additional 4-20 mA analog signals.
With the HART protocol it is possible to use multidrop configuration. In this case communication is restricted to digital since current is fixed to the 4 mA minimum value.
The transmitter can be connected to a Rosemount 751 Field Signal Indicator or it can be equipped with an integral display.
The transmitter can easily be configured by using a 375 Field Communicator or a PC with the Rosemount Radar Master software. Rosemount 5300 Series transmitters are also compatible with the AMS Suite and DeltaV software, and other tools supporting Electronic Device Description Language (EDDL) functionality. These tools can be used for configuration.
For HART communication a minimum load resistance of 250 Ohm within the loop is required.

See the source image

ROSEMOUNT ROSEMOUNT 5300 SERIES TOP MOUNT LEVEL RADAR

Product Details

5301 Enhanced Guided Wave RadarSee the source image

Emerson’s 5300 series of high performance guided wave transmitters are suitable for both level and interface measurement delivering accurate results with minimal maintenance and calibration requirements.
Utilising guided wave measurement technology the 5301 can be used in applications where both vapour and turbulence are present and does not require compensation for changes in temperature, density or pressure and can be installed in most level and liquid storage applications including those with small tanks, obstructions and difficult storage vessel geometry.

Features and Benefits

Unique Direct Switch Technology and Probe End Projection improve capability and reliability particularly in challenging applications.
Single lead probe for long measuring ranges, obstructions and low dielectrics ensures reliability in more applications, such as viscous media.
Smart Galvanic Interface results in a more stable microwave and EMI performance with minimized effects from outside disturbances.
Heavy-duty unique hardware for extreme temperature and pressures with multiple layers of protection.
EchoLogics and smart software functions provide enhanced ability to keep track of the surface and detect a full vessel situation.
Third party approved for overfill prevention and Safety Integrated System SIL3 suitability.
Electronics and cable connections in separate compartments provides safer handling and improved moisture protection.
Online device verification and reliable detection of high level conditions with the verification reflector.

Specifications

Not what you’re looking for? Select the attributes you require, then click the button below
Device Type Guided Wave Radar
Mounting Type Top Mount
Body Material Polyurethane-covered Aluminium
Cable Length 10m
Minimum Operating Temperature -15°C
Maximum Operating Temperature +150°C
Maximum DC Voltage 42.4V
Maximum Pressure 40bar
Standards Met ATEX, CSA, EAC, EU, FM, IE, IEC, IM, NCC, SBS, SBV, SDN, SIL, SIS, SLL
Series Rosemount 5300