SCADA system SIMATIC WinCC WinCC/Redundancy

WinCC/Redundancy
  • Option for SIMATIC WinCC, supporting the parallel operation of two interfaced WinCC single-user systems or process data servers for mutual monitoring
  • If one of the two server PCs or one of the two WinCC stations fails, the second one will take over control of the entire system. Once the failed server or station is restored to operation, the content of all the message and process value archives are copied to it.
  • One WinCC/Redundancy package is required for each redundant pair of servers.

1.Bank/Wire Transfer

2.Western union

3.PayPal

4.Cheque (Check)

5.We accept currency: USD, or RMB or EUR

12-Month-Warranty-dental-ha12 Month Warranty On All Parts100% Tested & Cleaned Guaranteed100-Cleaned-GuaranteedFree Technica Support

We focus on industrial automation and process instrument over 20 years

Ordering data

Product No. / Product DescriptionListprice / Your price
6AV6371-1CF07-3AX0
SIMATIC WinCC/Redundancy V7.3, Option for SIMATIC WinCC V7.3, Runtime software, Single Lic. f. 2 installations
6AV6371-1CF07-4AX0
SIMATIC WinCC/Redundancy V7.4, Option for SIMATIC WinCC V7.4, Runtime software, Single Lic. f. 2 installations
6AV6371-1HF07-3AX0
SIMATIC WinCC/Redundancy V7.3, Option for SIMATIC WinCC V7.3, Runtime software, Single Lic. f. 2 installations License key download ******************************* E-mail address required for delivery
This product is downloadable only. This product is downloadable only.
6AV6371-1HF07-4AX0
SIMATIC WinCC/Redundancy V7.4, Option for WinCC V7.4, runtime software, Single license, License key download ******************************* E-mail address required for delivery

Benefits

  • Increased system availability with continuous data integrity
  • Automatic changeover of client in the event of failure of a server or failure of the communication to a server
  • Continuous operator control and visualization thanks to automatic client changeover to the intact server
  • Automatic updating of all archives in the background after rectification of the fault

Function

Normally, two WinCC stations or process data servers run in parallel. Each station has its own process connection and its own data archives. WinCC/Redundancy ensures automatic matching of system and user archive data.

If one of the two server computers or WinCC stations fails, the second will take over the archiving of messages and process data, thereby ensuring seamless data integrity. In client/server mode, the clients are automatically switched from the failed server to the redundant partner. This ensures continuous plant visualization and operation on every operator station.

When the failed partner resumes operation, all process values, messages and data archived during the fail period are automatically matched with the partner. This process runs in the background and does not affect plant continuity. Once this is complete, two equivalent servers/stations will be available again.

Communication with the SIMATIC S7 PLC can also be configured with redundancy (an H Series SIMATIC S7 is required) by plugging in two communication modules and configuring two communication paths (S7-REDCONNECT software package). The use of failsafe H Series SIMATIC S7 PLCs can, if required, further increase availability at control level.

Popular Products Series

Siemens Simatic S7-200 CN

Siemens Simatic S7-200 CN are Made in China. MFG is Siemens China…

SIEMENS SINAMICS G130 Chassis Units

SINAMICS G130 chassis units have been designed for variable-speed drives in machine building and plant construction.
They have been specially tuned to the requirements of drives with quadratic or constant load characteristics with medium performance requirements without regenerative feedback.

GE QuickPanel family of Human Machine Interfaces Ge Fanuc HMI

The GE Automation QuickPanel+ HMI is more than just a human-machine interface; streamline your system with an OI/HMI, PLC/process controller, machine gateway, and data historian capable device all-in-one. It is made to handle industrial environments and is as easy to use as a smart phone or tablet, with just the swipe or tap of a finger.

Mitsubishi F740 Series Frequency Inverter

The FR-F700 Series was launched in 2004 as the successor to the FR-F500 Series VFD. With growing market demands for energy saving inverters in building automation, water processing and HVAC industries, the FR-F700 was able to exceed power-saving expectations in fan and pump applications by incorporating “OEC” (optimum excitation control) which combined maximum drive utilization with minimal power consumption.

Siemens PLC spare part 6AV 6DD 6SN 6ES5 6ES7

Main supply Siemens 6ES7 6AV6 6AV3 6SE7 Spare parts...

6RM80 SINAMICS DCM Cabinets

We provide the assembled version of 6RM80 product, and all the accessories are from the official Siemens, which are 100% tested and strictly tested before delivery.
Please consult our sales department for price.

Allen-Bradley 6176M Standard Industrial Monitors

Allen-Bradley 6176M Standard Industrial Monitors,6176M Standard Monitors are flat panel industrial color monitors for use in less demanding environments. All Standard Monitors have USB and RS232 touch screen inputs, DVI and VGA video inputs, and an On Screen Display (OSD) that enables image rotation, color pallet changes, and push button auto reset.

Allen-Bradley 6186M Performance Monitors

Bulletin 6186M - Performance Industrial Monitors




1200M,…
Load more