SIMOREG DC-MASTER 6RA70
SIMOREG DC-MASTER chassis converters 6RA70
for single-quadrant operation B6C
3-ph. 460 V AC
  • rated input current: 30 A to 1200 A
  • rated DC voltage: 550 V
  • rated output: 16.5 kW to 660 kW

DC Drive 6RA70 3-ph. AC 460 V Technical specifications

Type

6RA70..-
6FS22

18

25

28

31

Rated supply voltage
armature 1)

V

3-ph. AC 460 (+15 % / -20 %)

Rated input current armature 2)

A

25

50

75

104

Rated supply voltage electronics supply

V

2-ph. AC 380 (-25 %) to 460 (+15 %); In = 1 A or
1 AC 190 (-25 %) to 230 (+15 %);In = 2 A
(-35 % for 1 min)

Rated supply voltage
field 1)

V

2-ph. AC 460 (+15 % / -20 %)

Rated frequency

Hz

45 to 65 8)

Rated DC voltage 1)

V

550

Ratede DC current

A

30

60

90

125

Overload capability

Max. 1.8 times rated DC current

Rated output

kW

16.5

33

49.5

68.7

Power loss at rated DC current (approx.)

W

172

248

363

417

Rated DC voltage
field 1)

V

max. 375

Rated DC current field

A

5

10

Operational ambient temperature

°C

0 to 45 at I rated 3) self-cooled

Storage and transport temperature

°C

-25 to +70

Installation altitude
above sea level

≤ 1000 m at rated DC current 4)

Dimensions
(H x W x D)

mm

385 x 265 x 239

385 x 265 x 313

Weight (approx.)

kg

11

15

17

17

Type

6RA70..-
6FS22

75

78

82

85

Rated DC voltage
armature 1)

V

3-ph. AC 460 (+15 % / -20 %)

Rated DC current armature 2)

A

175

233

374

498

Rated supply voltage electronics supply

V

2-ph. AC 380 (-25 %) to 460 (+15 %); In = 1 A or
1-ph. AC 190 (-25 %) to 230 (+15 %);In = 2 A
(-35 % for 1 min)

Rated supply voltage field

V

DC 24 V internal

1-ph. AC 230 (±10 %)

50 Hz

60 Hz

Nominal fan current

A

0.55

0.55

Air flow rate

m3/
h

100

570

570

Fan noise level

dBA

40

73

76

Rated supply voltage
field 1)

2-ph. AC 460 (+15 % / -20 %)

Rated frequency

Hz

45 to 65 8)

Rated DC voltage 1)

V

480

Rated DC current

A

210

280

450

600

Overload capability

Max. 1.8 times rated DC current

Rated output

kW

100

134

216

288

Power loss at rated DC current (approx.)

W

700

792

1519

1845

Rated DC voltage
field 1)

V

max. 375

Rated Dc current field

A

15

25

Operational ambient temperature

°C

0 to 40 at I rated 3) separately cooled

Lager- und
Transport-
temperatur

°C

-25 bis +70

Installation altitutude
above sea level

≤ 1000 m at rated DC current 4)

Dimensions
(H x W x D)

mm

385 x 265 x 313

625 x 268 x 318

Weight (approx.)

kg

17

18

32

Type

6RA70..-6FV62

87

91

Rated supply voltage
armature 1)

V

3-ph. AC 460
(+15 % / -20 %)

Rated input current
armature 2)

A

705

995

Rated supply voltage electronics supply

V

2-ph. AC 380 (-25 %) to 460 (+15 %);
In = 1 A or
1 AC 190 (-25 %) to 230 (+15 %);
In = 2 A
(-35 % for 1 min)

Rated supply voltage
fan

V

1-ph. AC 230 (±10 %)

1-ph. AC 230 (±10 %)

50 Hz

60 Hz

50 Hz

60 Hz

Nominal fan current

A

0.55

0.75

2.6

3.3

Air flow rate

m3/h

570

570

1300

1300

Fan noise level

dBA

73

76

82

85

Rated supply voltage
field 1)

V

2 AC 460 (+15 % / -20 %)

Rated frequency

45 to 65 8)

Rated DC voltage

V

480

Rated DC current

A

850

1200

Overload capability

Max. 1.8 times rated DC current

Rated output

kW

408

576

Power loss at rated DC current (approx.)

W

2514

4620

Rated DC voltage
field 1)

V

max. 375

Rated DC field

A

30

Operational ambient temperature

°C

0 to 40 at I rated 3) separately cooled

Storage and transport temperature

°C

-25 to +70

Installation altitude
above sea level

≤ 1000 m at rated DC current 4)

Dimensions
(H x W x D)

mm

700 x 268 x 362

780 x 410 x 362

Weight (approx.)

kg

47

85

1) The armature/field supply voltage can be less than the rated supply voltage armature/field (set with Parameter P078; for converters with 400 V rated voltage, input voltages of up to
85 V are permissible). The output voltage is reduced accordingly. The specified output DC voltage can be guaranteed up to undervoltages 5 % below the supply voltage (rated supply voltage armature/field).

2) Values apply to output rated DC current.

3) Load factor K1 (DC current) as a function of the coolant temperature (see P077 Operating Instructions).
K1 > 1 only permissible where K1 * K2 ≤ 1st. overall reduction factor K = K1 * K2 (for K2 see Footnote 4)

Ambient or cooling temperature

Load
factor K1

In devices with self-cooling

In devices with enhanced cooling

≤ +30 °C

1.18

1.10

+35 °C

1.12

1.05

+40 °C

1.06

1.00

+45 °C

1.00

0.95

+50 °C

0.94

0.90 a)

+55 °C

0.88

+60 °C

0.82 b)

a) In spite of derating, converters of ≥ 400 A with enhanced cooling may be operated at an ambient or coolant temperature of 50 ºC only if the rated supply voltage of the converter fan is safely within the limited tolerance range of 400 V +10 % -15 %.

b) Not permissible when T400 or OP1S are used.

4) Load values K2 as a function of the installation altitude (see P077 Operating Instructions,);
Overall reduction factor K = K1 * K2 (for K1 see Footnote 3).

Ambient or coolant tem-
pera-
ture m

1000

2000

3000

4000

5000

Reduction
factor K2

1.0

0.835

0.74

0.71

0.67

The supply voltages for all electric circuits are possible for site altitudes up to 5000 m with basic insulation,
with the exception of converters for rated supply voltages:

Installation altitude

Rated supply voltage

830 V

950 V

Up to 4000 m

max. 830 V

950 V

Up to 4500 m

max. 795 V

933 V

Up to 5000 m

max. 727 V

881 V

Popular Products Series

ABB DRIVES DCS 500 DC DRIVES

The DCS 500 takes advantage of ABB’s extensive experience in DC drives. High quality components together with the latest production technology guarantee reliable operation and customer satisfaction. Performance with flexibility for industrial or commercial applications.

SIEMENS DC MASTER SINAMICS DCM Control Module

The SINAMICS DC MASTER Control Module offers the optimum solution when retrofitting and modernizing existing DC drives. Contrary to the SINAMICS DC MASTER DC Converter, which comprises open-loop control, closed loop control and power unit, the Control Module is especially used if, as part of the modernization, the power unit of the existing plant or system should be kept. When it comes to quality, reliability and functionality, the SINAMICS DC MASTER Control Module is exactly the same as its predecessor – the SIMOREG CM; however, when it comes to functionality, it offers new features from the range of the SINAMICS DC MASTER.

SIEMENS SIMODRIVE 611 UNIVERSAL

SIMOREG DC Master 6RA70 Series – SIEMENS 6RA70 Conrol Module

SIMOREG 6RA70 converters are fully digital, compact units for connection to a three-phase AC supply. They in turn supply the armature and field of variable-speed DC drives. The range of rated DC currents extends from 15 A to 3000 A, but can be expanded by connecting SIMOREG converters in parallel.

Siemens DC Drive 6RA70 3-ph. AC 950 V

SIMOREG DC-MASTER chassis converters 6RA70, 3-ph. 950 V AC

Siemens DC Drive 6RA70 3-ph. AC 830 V

Siemens DC Drive 6RA70 3-ph. AC 690 V

SIMOREG DC-MASTER converter chassis 6RA70, for single-quadrant operation B6C, 3–ph. 690 V AC

Siemens DC Drive 6RA70 3-ph. AC 575 V

Load more