SIEMENS HMI Software – SIMATIC WinCC [email protected] (TIA Portal)

WinCC Sm@rtServer

WinCC [email protected]

  • Option for SIMATIC WinCC Runtime Advanced plus SIMATIC Panels for communication between various SIMATIC HMI systems.
  • Available for the following SIMATIC HMI systems:
    • Basic Panels 2nd generation
    • Comfort Panels
    • Mobile Panel 2nd generation, Mobile Panel 277, Mobile Panel 177 PN
    • TP 177B PN/DP, OP 177B PN/DP
    • TP 277, OP 277
    • MP 177, MP 277, MP 377
    • WinCC Runtime Advanced
  • A SIMATIC HMI system can be used to control or monitor another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with head end or control room
  • Local operation, visualization and data processing are as possible as plant-wide access to information. Integrated information flows ensure an overview of the status of all processes.
  • Licensing:
    The “SIMATIC WinCC [email protected] for Panel” or “SIMATIC WinCC [email protected] for Basic Panel” or “SIMATIC WinCC [email protected] for Runtime Advanced” license must be installed on the server HMI device.
    A separate license is no longer required for Comfort / Mobile Panels Version V14 or higher and for Runtime Advanced Version V14 SP1 or higher.
    A license is not required for the engineering system for configuring the runtime option.

Product No. / Product DescriptionSIMATIC WinCC [email protected] Ordering data
6AV2107-0CA00-0BB0
SIMATIC WinCC [email protected] for Runtime Advanced; option for WinCC V11 – V14; Integrated in WinCC as of V14 SP1; Runtime-SW, single license w/o sw and docu. license key on USB stick, class A
6AV2107-0CA00-0BH0
SIMATIC WinCC [email protected] for Runtime Advanced; option for WinCC V11 – V14; Integrated in WinCC as of V14 SP1; License key download, single license F.1 installation RT-SW, w/o sw and docu, class A ******************************* e-mail address is mandatory for delivery!
6AV2107-0CP00-0BB0
SIMATIC WINCC [email protected] SERVER FOR SIMATIC PANELS OPTION FOR WinCC V11, V12, V13; RUNTIME-SW, SINGLE LICENSE WITHOUT SW AND DOCU. LICENSE KEY ON USB STICK, CLASS A
6AV2107-0CP00-0BH0
SIMATIC WINCC [email protected] SERVER FOR SIMATIC PANELS OPTION FOR WinCC V11, V12, V13; LICENSE KEY DOWNLOAD, SINGLE LICENSE F.1 INSTALLATION RT-SW, W/O SW AND DOCU, CLASS A ******************************* E-MAIL ADDRESS IS MANDATORY FOR DELIVERY!
6AV2107-0CR00-0BB0
SIMATIC WinCC [email protected] for SIMATIC Basic Panels, Option for WinCC V14 or higher; runtime software in TIA Portal; single license; w/o software and documentation; license key on USB stick; class A;
6AV2107-0CR00-0BH0
SIMATIC WinCC [email protected] for SIMATIC Basic Panels, Option for WinCC V14 or higher; runtime software in TIA Portal; single license; license key for download; without software and documentation; class A; ******************************* email address is mandatory for delivery

Benefits

  • Flexible solution for remote access to HMI systems
  • Quick elimination of malfunctions or downtimes – thus increasing the productivity – through global access to machines/plants by the service and maintenance personnel.
  • Avoidance of on-site service calls.

Application

  • Operator control and monitoring of machines covering large areas with several operator stations by one operator.
  • Operator control and monitoring of machine-level HMI systems from one central station (e.g. head-end station of a production line or from a control room)
  • Remote maintenance and servicing of machines/plants over the Internet/Intranet

Application of the [email protected] concept: Coordinated operation of several operator stations

Use of the [email protected] display: Operator control and monitoring of machine-level HMI systems from one central station

Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet

Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet


Function

Coordinated operation of several operator stations:

  • The HMI application and communication with the controller takes place via the master station. “[email protected]” can be activated from here in the case of machines/plants with larger dimensions which require a larger number of operator panels. The [email protected] are then provided with access to the master station and thus to the process. Access procedures guarantee that only one operator system can actively access the process at any given time.
  • Embedded in process screens, a configurable screen object ([email protected] display) represents the screen of the relevant HMI system ([email protected])
  • Powerful standard functions permit user-friendly and flexible operation of the display

Remote control of an operating station:

  • The HMI application and communication with the controller takes place via the HMI system. Using the [email protected], the HMI systems in the machines/systems can be serviced remotely. An access process ensures that only one operator (either locally at the machine or remotely via Internet Explorer) can actively access the process at one time.
  • Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for accessing an HMI system.

Technical specifications

WinCC [email protected]

The values specified are maximum values

Execution platform

SIMATIC Basic Panels 2nd Generation

all

SIMATIC Comfort Panels

all

SIMATIC Panels

Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 277

SIMATIC Multi Panels

MP 177,
MP 277,
MP 377

PC systems

SIMATIC WinCC Runtime Advanced

Number of [email protected] that can simultaneously connect to a [email protected]

SIMATIC Basic Panels 2nd Generation

1 client

Comfort Panel, Mobile Panel 2nd Generation
as [email protected]

2 clients for 4″ devices
3 clients for 7″, 9″, 12″ and 15″ devices
2 clients for 19″ devices
1 client for 22″ devices

Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as [email protected]

2 clients

Mobile Panel 277,
TP/OP 277,
MP 277 as [email protected]

3 clients for 6″ devices
2 clients for 8″ and 10″ devices

MP 377 as [email protected]

3 clients for 12″ devices
2 clients for 15″ devices
1 client for 19″ devices

WinCC Runtime Advanced as [email protected]

5 clients