SIEMENS S7-1500 SIPLUS Standard SIPLUS CPU 1513-1 PN

SIPLUS CPU 1513-1 PN

  • The CPU for applications with medium/high requirements for program/data storage in the S7-1500 controller product range
  • High processing speed for binary and floating-point arithmetic
  • Used as central controller in production lines with central and distributed I/O
  • PROFINET IO IRT interface with 2-port switch
  • PROFINET IO Controller for operating distributed I/O on PROFINET
  • PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET I/O controller
  • Isochronous mode
  • SIMATIC memory card required for operation of the CPU

Please note:

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

SEIMENS SIPLUS CPU 1513-1 PN Ordering data

Product No. / Product DescriptionListprice / Your price
6AG1513-1AL01-2AB0
SIPLUS S7-1500 CPU 1513-1 PN -40 … +60 GRAD C STARTUP -20 GRAD C MIT CONFORMAL COATING BASED ON 6ES7513-1AL01-0AB0 . CENTRAL PROCESSING UNIT WITH WORKING MEMORY 300 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY
6AG1513-1AL01-7AB0
SIPLUS S7-1500 CPU 1513-1 PN -40 … +70 Degrees C Sartup -20 Degrees C with conformal coatingf Based on 6ES7513-1AL01-0AB0 . Central processing unit with working Memory 300 KB for Program and 1.5 MB for data, 1. Interface: PROFINET IRT with 2 port switch, 40 NS Bit-performance, SIMATIC Memory card necessary

The CPU 1513-1 PN features:

  • A powerful processor:
    The CPU achieves command execution times as low as 40 ns per binary instruction.
  • A large work memory:
    300 KB for program, 1.5 MB for data
  • SIMATIC Memory Cards as load memory;
    permit additional functions such as datalog and archives
  • Flexible expansion capability:
    single-tier configuration with max. 32 modules (CPU + 31 modules)
  • Display with functions for:
    • Display of overview information such as IP address of the integrated interface, station name, higher level designation, location designation, etc.,
    • Display and acknowledgment of diagnostic and user messages
    • Display of module information
    • Showing display settings
    • Display of a user-definable logo
    • Setting of IP addresses
    • Setting of date and time
    • Selection of the operating mode
    • Resetting of the CPU to factory settings
    • Backup and restoring of the project
    • Disabling/enabling of the display
    • Enabling of protection levels
  • PROFINET IO IRT interface for connecting distributed I/O via PROFINET