SIEMENS S7-300 CPU 317TF-3 PN/DP controller

  • Fail-safe SIMATIC CPU 317TF-3 PN/DP with integral technology/motion control functionality
  • Spare-part-compatible successor to the CPU 317TF-2 DP (Article No. 6ES7317-6TF14-0AB0)
  • With full functionality of the standard CPU 317-2 PN/DP and CPU 317F-2 PN/DP (except for CBA)
  • For cross-industry automation tasks in series machine, special machine and plant construction
  • Ideal for synchronized motion, such as coupling to a virtual/real master, gear synchronization, cam disk, path interpolation, or print mark compensation
  • 3D path interpolation with different kinematics
  • Position and pressure-regulated hydraulic axes
  • Used as central controller in production lines with central and distributed I/O
  • With integrated I/O for high-speed technology functions (e.g. camming, reference point acquisition)
  • PROFIBUS DP (DRIVE) interface for isochronous connection of drive components
  • PROFINET interface with 2-port switch
  • PROFINET IO controller for operating distributed I/O on PROFINET
  • One common S7 user program for control and motion control tasks (no additional programming language necessary for motion control)
  • “S7 Technology” option package required
  • “S7 Distributed Safety” option package required (version V4.2 SP3 and higher)

SIMATIC Micro Memory Card (8 MB) required for operation of the CPU.

Product No. / Product Description

CPU 317TF-3 PN/DP Ordering data

6ES7317-7UL10-0AB0
SIMATIC S7-300, CPU 317TF-3 PN/DP, CENTRAL PROCESSING UNIT FOR PLC, TECHNOLOGY AND SAFETY, 1,5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP(DRIVE), 3. INTERFACE ETHERNET PROFINET WITH 2 PORT SWITCH, INTEGRATED I/O FOR TECHNOLOGY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD MIN. 8 MB NECESSARY

The CPU 317TF-3 PN/DP is a controller that enables motion control, standard and safety tasks to be performed in one controller. It is used in machines where a controller with a large program memory and high processing speed is confronted by motion control requirements at the same time, e.g.:CPU 317TF-3 PN/DP

  • Processing/assembly lines
  • Palletizers
  • Handling systems
  • Carton erectors
  • Flying shears
  • Bottling plants
  • Wrapping
  • Labeling machines
  • Roll feeds
  • Portals with interpolation

The typical application for motion control functions is for 3-8 axes. The maximum number of axes is 32. Along with accurate single axis positioning, the module is suitable primarily for complex motion sequences such as coupling to form a virtual or actual master, gearing, cam, path interpolation or print mark correction.

The quantitative framework of the CPU 317TF-3 PN/DP makes it ideal for the use of SIMATIC Engineering Tools, e.g.:

  • Programming with SCL
  • Machining step programming with S7-GRAPH

Design

The CPU 317TF-3 PN/DP has the same functionality as the high-performance CPU 317 as well as additional integrated functions for technology/motion control. Integrated, fast I/O for technical functions such as cam switching or home position detection round off the performance range the module. Thanks to the integration of Safety Integrated, the controller for safety-oriented applications complies with the high safety requirements according to the relevant standards IEC 62061 to SIL 3, and EN ISO 13849-1 to PL e.

For the fail-safe applications, the STEP 7 option package Distributed Safety provides ready-made TÜV-certified library blocks, e.g. for emergency-stop, two-hand control, muting and door monitoring.

The CPU 317TF-3 PN/DP features:

  • Microprocessor;
    the processor can handle execution times of approx. 0.025 µs per binary instruction and 0.16 µs per floating-point instruction. The CPU 317TF-3 PN/DP reaches very high processing speeds, particularly where word or double-word commands and 32 bit fixed-point commands are concerned.
  • 1.5 MB main memory;
    The extensive main memory for runtime-relevant program sections offers sufficient space for user programs. SIMATIC Micro Memory Cards (8 MB) as load memory for the program also allow the project to be stored in the CPU (complete with symbols and comments) and can be used for data archiving and recipe management.
  • Integrated inputs and outputs for technical functions;
    4 digital inputs and 8 digital outputs, can be used for technical functions such as reference point acquisition (BERO) or rapid cam switching signals.
    The digital inputs can also be used (with some restrictions) in the STEP 7 user program.
  • Flexible expansion;
    up to 8 modules (single-tier configuration)
  • Combined MPI/DP interface;
    The first MPI/DP integrated interface can establish as many as 32 connections simultaneously to S7-300/400 or connections to PG, PC, OP. Among these connections, one is always reserved for programming devices and another for OPs. A simple network with up to 32 CPUs can be configured with the MPI and “global data communication”.
    This interface can be reconfigured from an MPI to a PROFIBUS DP interface. The DP interface can be used as a DP master or as a DP slave.
  • PROFIBUS DP (DRIVE) interface:
    The PROFIBUS DP (DRIVE) interface supports isochronous mode and therefore provides an essential requirement to control high-speed and time-critical operations, such as are found in distributed axes in synchronized applications. The interface can only be used as a DP master. It serves to connect drive components. DP-V0 slaves can also be operated on the DP (DRIVE) spur on a limited basis in addition to drive systems. The connectable drives are specified in the technical specifications.
  • PROFINET
    The third integral interface of the CPU 317TF-3 PN/DP is a PROFINET interface with 2-port switch, based on Ethernet TCP/IP.
    It supports the following protocols:

    • S7 communication for data communication between SIMATIC controllers
    • PG/OP communication for programming, commissioning and diagnostics through STEP 7
    • PG/OP communication for interfacing to HMI and SCADA
    • Open TCP/IP, UDP and ISO-on-TCP (RFC1006) communication over PROFINET
    • SIMATIC NET OPC-Server for communication with other controllers and I/O devices with own CPU
Function

The CPU 317TF-3 PN/DP has the full functionality of the CPU 317F-2 PN/DP (except for CBA). In addition, high-performance motion control functions are available.

The programming is carried out with STEP 7 as well as the option package S7-Technology.

In S7 Technology V4.2 or higher, the following kinematics are supported:

  • Cartesian (two and three-dimensional)
  • Roll picker
  • Scara
  • Articulated arm
  • Delta2D picker
  • Delta3D picker

The following motion control functions can be used with the CPU 317TF-3 PN/DP:

  • Basic functions
    • MC_ReadSysParameter
    • MC_Reset
    • MC_WriteParameter
  • Single-axis functions
    • MC_ChangeDataset
    • MC_Halt
    • MC_Home
    • MC_MoveAbsolute
    • MC_MoveAdditive
    • MC_MoveRelative
    • MC_MoveSuperImposed
    • MC_MoveToEndPos
    • MC_MoveVelocity
    • MC_Power
    • MC_SetTorqueLimit
    • MC_Stop
  • Synchronous operation functions
    • MC_CamIn
    • MC_CamOut
    • MC_GearIn
    • MC_GearOut
    • MC_Phasing
  • Superimposed synchronous operation functions
    • MC_CamInSuperImposed
    • MC_CamOutSuperImposed
    • MC_GearInSuperImposed
    • MC_GearOutSuperImposed
    • MC_PhasingSuperImposed
  • Cam functions
    • MC_CamClear
    • MC_CamInterpolate
    • MC_CamSectorAdd
    • MC_GetCamPoint
  • Other functions
    • MC_CamSwitch
    • MC_CamSwitchTime
    • MC_ExternalEncoder
    • MC_MeasuringInput
    • MC_ReadPeriphery
    • MC_ReadRecord
    • MC_WritePeriphery
    • MC_WriteRecord
  • Drive functions
    • MC_DriveDiagnostics
    • MC_ReadDriveParameter
    • MC_WriteDriveParameter
  • Pressure/Force commands
    • MC_ForceLimiting
    • MC_ForceControl
  • Path commands
    • MC_SetCartesianTransform
    • MC_GroupStop
    • MC_GroupInterrupt
    • MC_GroupContinue
    • MC_MoveLinearAbsolute
    • MC_MoveLinearRelative
    • MC_MoveCircularAbsolute
    • MC_MoveCircularRelative
    • MC_MovePath
    • MC_PathSelect
    • MC_MovePolynomialAbsolute
    • MC_MovePolynomialRelative
    • MC_ZoneCheck
    • MC_GroupSyncConveyorBelt
    • MC_RedefineTrackingPos
    • MC_MoveCircles
Technical specifications

Article number

6ES7317-7UL10-0AB0

CPU317TF-3 PN/DP, 1,5 MB

General information

HW functional status

01

Firmware version

CPU: V3.2; integrated technology V4.1.5

Engineering with

  • ● Programming package

STEP 7 V5.5 SP2 or higher; S7-Technology option package V4.2 SP3 or higher, Distributed Safety V5.4 SP5 or higher, S7-F Configuration Pack V5.5 SP10 or higher

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

external protection for power supply lines (recommendation)

2 A min.

Load voltage L+

  • ● Rated value (DC)

24 V

  • ● Reverse polarity protection

Yes

Digital outputs

  • — Rated value (DC)

24 V; 2L+

  • — Reverse polarity protection

No; 2L+

Input current

Current consumption (rated value)

1 100 mA

Current consumption (in no-load operation), typ.

270 mA

Inrush current, typ.

6.5 A

I²t

1 A²·s

Power loss

Power loss, typ.

8.5 W

Memory

Work memory

  • ● integrated

1 536 kbyte

  • ● expandable

No

  • ● Size of retentive memory for retentive data blocks

256 kbyte

Load memory

  • ● Plug-in (MMC)

Yes

  • ● Plug-in (MMC), max.

8 Mbyte

  • ● Data management on MMC (after last programming), min.

10 y

Backup

  • ● present

Yes; Guaranteed by MMC (maintenance-free)

  • ● without battery

Yes; Program and data

CPU processing times

for bit operations, typ.

0.025 µs

for word operations, typ.

0.03 µs

for fixed point arithmetic, typ.

0.04 µs

for floating point arithmetic, typ.

0.16 µs

CPU-blocks

Number of blocks (total)

2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

  • ● Number, max.

2 048; Number range: 1 to 16000

  • ● Size, max.

64 kbyte

FB

  • ● Number, max.

2 048; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

FC

  • ● Number, max.

2 048; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

OB

  • ● Description

see instruction list

  • ● Size, max.

64 kbyte

  • ● Number of free cycle OBs

1; OB 1

  • ● Number of time alarm OBs

1; OB 10

  • ● Number of delay alarm OBs

2; OB 20, 21

  • ● Number of cyclic interrupt OBs

4; OB 32, 33, 34, 35

  • ● Number of process alarm OBs

1; OB 40

  • ● Number of DPV1 alarm OBs

3; OB 55, 56, 57

  • ● Number of isochronous mode OBs

1; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously)

  • ● Number of technology synchronous alarm OBs

1; OB 65

  • ● Number of startup OBs

1; OB 100

  • ● Number of asynchronous error OBs

6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)

  • ● Number of synchronous error OBs

2; OB 121, 122

Nesting depth

  • ● per priority class

16

  • ● additional within an error OB

4

Counters, timers and their retentivity

S7 counter

  • ● Number

512

Retentivity

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

511

  • — preset

Z 0 to Z 7

Counting range

  • — can be set

Yes

  • — lower limit

0

  • — upper limit

999

IEC counter

  • ● Number

Unlimited (limited only by RAM capacity)

S7 times

  • ● Number

512

Retentivity

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

511

  • — preset

No retentivity

Time range

  • — lower limit

10 ms

  • — upper limit

9 990 s

IEC timer

  • ● present

Yes

  • ● Type

SFB

  • ● Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

All, max. 256 KB

Flag

  • ● Number, max.

4 096 byte

  • ● Retentivity available

Yes; From MB 0 to MB 4095

  • ● Retentivity preset

MB 0 to MB 15

  • ● Number of clock memories

8; 1 memory byte

Data blocks

  • ● Number, max.

2 048; Number range: 1 to 16000

  • ● Size, max.

64 kbyte

  • ● Retentivity adjustable

Yes; via non-retain property on DB

  • ● Retentivity preset

Yes

Local data

  • ● per priority class, max.

32 768 byte; Max. 2048 bytes per block

Address area

I/O address area

  • ● Inputs

8 192 byte

  • ● Outputs

8 192 byte

of which distributed

  • — Inputs

8 192 byte

  • — Outputs

8 192 byte

Process image

  • ● Inputs

8 192 byte

  • ● Outputs

8 192 byte

  • ● Inputs, adjustable

8 192 byte

  • ● Outputs, adjustable

8 192 byte

  • ● Inputs, default

1 024 byte

  • ● Outputs, default

1 024 byte

Default addresses of the integrated channels

  • — Digital inputs

66

  • — Digital outputs

66

Subprocess images

  • ● Number of subprocess images, max.

1; With PROFINET IO, the length of the user data is limited to 1600 bytes

Digital channels

  • ● Inputs

65 536

  • — of which central

256

  • ● Outputs

65 536

  • — of which central

256

Analog channels

  • ● Inputs

4 096

  • — of which central

64

  • ● Outputs

4 096

  • — of which central

64

Hardware configuration

Number of expansion units, max.

0

Number of DP masters

  • ● integrated

2; 1 DP and 1 DP (drive)

  • ● via CP

2; for DP

Number of operable FMs and CPs (recommended)

  • ● FM

8

  • ● CP, PtP

8

  • ● CP, LAN

8

Rack

  • ● Racks, max.

1

  • ● Modules per rack, max.

8

Time of day

Clock

  • ● Hardware clock (real-time)

Yes

  • ● retentive and synchronizable

Yes

  • ● Backup time

6 wk; At 40 °C ambient temperature

  • ● Deviation per day, max.

10 s; Typ.: 2 s

  • ● Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • ● Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

  • ● Number

4

  • ● Number/Number range

0 to 3

  • ● Range of values

0 to 2^31 hours (when using SFC 101)

  • ● Granularity

1 hour

  • ● retentive

Yes; Must be restarted at each restart

Clock synchronization

  • ● supported

Yes

  • ● to MPI, master

Yes

  • ● to MPI, slave

Yes

  • ● to DP, master

Yes

  • ● to DP, slave

Yes; Only time-of-day slave

  • ● in AS, master

Yes

  • ● in AS, slave

Yes

  • ● on Ethernet via NTP

Yes; As client

Digital inputs

Number of digital inputs

4

  • ● of which inputs usable for technological functions

4

Input characteristic curve in accordance with IEC 61131, type 1

Yes

horizontal installation

  • — up to 40 °C, max.

4

  • — up to 60 °C, max.

4

vertical installation

  • — up to 40 °C, max.

4

Input voltage

  • ● Rated value (DC)

24 V

  • ● for signal “0”

-3 to +5V

  • ● for signal “1”

+15 to +30V

Input current

  • ● for signal “1”, typ.

7 mA

for counter/technological functions

  • — at “0” to “1”, max.

10 µs; Typical

  • — at “1” to “0”, max.

10 µs; Typical

Cable length

  • ● shielded, max.

1 000 m

Digital outputs

Number of digital outputs

8

  • ● of which high-speed outputs

8

Functions

For technology functions, e.g. high-speed cam switch signals

Short-circuit protection

Yes

  • ● Response threshold, typ.

1 A

Limitation of inductive shutdown voltage to

48 V

Controlling a digital input

No

Switching capacity of the outputs

  • ● on lamp load, max.

5 W

Load resistance range

  • ● lower limit

48 Ω

  • ● upper limit

4 kΩ

Output voltage

  • ● for signal “0”, max.

3 V; (2L+)

  • ● for signal “1”, min.

Rated voltage -2.5 V

Output current

  • ● for signal “1” rated value

0.5 A

  • ● for signal “1” permissible range for 0 to 60 °C, min.

5 mA

  • ● for signal “1” permissible range for 0 to 60 °C, max.

0.6 A

  • ● for signal “0” residual current, max.

0.3 mA

Parallel switching of two outputs

  • ● for uprating

No

  • ● for redundant control of a load

No

Switching frequency

  • ● with resistive load, max.

100 Hz

  • ● with inductive load, max.

0.2 Hz; According to IEC 60947-5-1, DC-13

  • ● on lamp load, max.

100 Hz

horizontal installation

  • — up to 40 °C, max.

4 A

  • — up to 60 °C, max.

3 A

all other mounting positions

  • — up to 40 °C, max.

4 A

Integrated high-speed cams

  • ● Switching accuracy (+/-)

70 µs

Cable length

  • ● shielded, max.

1 000 m

Analog inputs

Number of analog inputs

0

Analog outputs

Number of analog outputs

0

Connectable encoders

  • ● 2-wire sensor

No

Interfaces

Number of industrial Ethernet interfaces

1

Number of RS 485 interfaces

2

Number of RS 422 interfaces

0

1. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

  • ● MPI

Yes

  • ● PROFIBUS DP master

Yes

  • ● PROFIBUS DP slave

Yes

  • ● Point-to-point connection

No

MPI

  • ● Transmission rate, max.

12 Mbit/s

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

Yes

  • — S7 basic communication

Yes

  • — S7 communication

Yes

  • — S7 communication, as client

No; but via CP and loadable FB

  • — S7 communication, as server

Yes

DP master

  • ● Transmission rate, max.

12 Mbit/s

  • ● Number of DP slaves, max.

124

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

No

  • — S7 basic communication

Yes; I blocks only

  • — S7 communication

Yes

  • — S7 communication, as client

No

  • — S7 communication, as server

Yes

  • — Equidistance

Yes

  • — Isochronous mode

Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Number of DP slaves that can be simultaneously activated/deactivated, max.

8

  • — Direct data exchange (slave-to-slave communication)

Yes; As subscriber

  • — DPV1

Yes

Address area

  • — Inputs, max.

8 kbyte

  • — Outputs, max.

8 kbyte

User data per DP slave

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

DP slave

  • ● Transmission rate, max.

12 Mbit/s

  • ● automatic baud rate search

Yes; only with passive interface

  • ● Address area, max.

32

  • ● User data per address area, max.

32 byte

Services

  • — PG/OP communication

Yes

  • — Routing

Yes; Only with active interface

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes

  • — S7 communication, as client

No

  • — S7 communication, as server

Yes; Connection configured on one side only

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV1

No

Transfer memory

  • — Inputs

244 byte

  • — Outputs

244 byte

2. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

  • ● MPI

No

  • ● PROFIBUS DP master

Yes; DP(DRIVE)-Master

  • ● PROFIBUS DP slave

No

  • ● Point-to-point connection

No

DP master

  • ● Transmission rate, max.

12 Mbit/s

  • ● Number of DP slaves, max.

64

Services

  • — PG/OP communication

No

  • — Routing

No

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

No

  • — Equidistance

Yes

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

No

  • — Activation/deactivation of DP slaves

Yes

  • — DPV1

No

Address area

  • — Inputs, max.

1 024 byte

  • — Outputs, max.

1 024 byte

User data per DP slave

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

DP slave

  • ● GSD file

http://support.automation.siemens.com in Product Support area

  • ● Transmission rate, max.

12 Mbit/s

3. Interface

Interface type

PROFINET

Physics

Ethernet RJ45

Isolated

Yes

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Interface types

  • ● Number of ports

2

  • ● integrated switch

Yes

Media redundancy

  • ● supported

Yes

  • ● Switchover time on line break, typ.

200 ms; PROFINET MRP

  • ● Number of stations in the ring, max.

50

Functionality

  • ● MPI

No

  • ● PROFINET IO Controller

Yes; Also simultaneously with IO-Device functionality

  • ● PROFINET IO Device

Yes; Also simultaneously with IO Controller functionality

  • ● PROFIBUS DP master

No

  • ● PROFIBUS DP slave

No

  • ● Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • ● Web server

Yes

  • — Number of HTTP clients

5

PROFINET IO Controller

  • ● Transmission rate, max.

100 Mbit/s

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — S7 communication

Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32

  • — Isochronous mode

Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO

  • — Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • — Shared device

Yes

  • — Prioritized startup

Yes

  • — Number of IO devices with prioritized startup, max.

32

  • — Number of connectable IO Devices, max.

128

  • — Of which IO devices with IRT, max.

64

  • — of which in line, max.

64

  • — Number of connectable IO Devices for RT, max.

128

  • — of which in line, max.

128

  • — Activation/deactivation of IO Devices

Yes

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • — IO Devices changing during operation (partner ports), supported

Yes

  • — Number of IO Devices per tool, max.

8

  • — Device replacement without swap medium

Yes

  • — Send cycles

250 µs, 500 µs, 1 ms, 2 ms, 4 ms

  • — Updating time

250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, Technical Data” for more details)

Address area

  • — Inputs, max.

8 kbyte

  • — Outputs, max.

8 kbyte

  • — User data consistency, max.

1 024 byte

PROFINET IO Device

Services

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — S7 communication

Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32

  • — Isochronous mode

No

  • — Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • — IRT

Yes

  • — PROFIenergy

Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device

  • — Shared device

Yes

  • — Number of IO Controllers with shared device, max.

2

Transfer memory

  • — Inputs, max.

1 440 byte; Per IO Controller with shared device

  • — Outputs, max.

1 440 byte; Per IO Controller with shared device

Submodules

  • — Number, max.

64

  • — User data per submodule, max.

1 024 byte

Open IE communication

  • ● Number of connections, max.

16

  • ● Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • ● Keep-alive function, supported

Yes

Protocols

Open IE communication

  • ● TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

  • — Data length for connection type 01H, max.

1 460 byte

  • — Data length for connection type 11H, max.

32 768 byte

  • — several passive connections per port, supported

Yes

  • ● ISO-on-TCP (RFC1006)

Yes; via integrated PROFINET interface and loadable FBs

  • — Data length, max.

32 768 byte

  • ● UDP

Yes; via integrated PROFINET interface and loadable FBs

  • — Data length, max.

1 472 byte

Web server

  • ● User-defined websites

Yes

  • ● Number of HTTP clients

5

Isochronous mode

Isochronous operation (application synchronized up to terminal)

Yes; Via PROFIBUS DP or PROFINET interface

Communication functions

PG/OP communication

Yes

Data record routing

Yes

Global data communication

  • ● supported

Yes

  • ● Number of GD loops, max.

8

  • ● Number of GD packets, max.

8

  • ● Number of GD packets, transmitter, max.

8

  • ● Number of GD packets, receiver, max.

8

  • ● Size of GD packets, max.

22 byte

  • ● Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

  • ● supported

Yes

  • ● User data per job, max.

76 byte

  • ● User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

  • ● supported

Yes

  • ● as server

Yes

  • ● as client

Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB

  • ● User data per job, max.

See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)

S5 compatible communication

  • ● supported

Yes; via CP and loadable FC

Web server

  • ● supported

Yes

Number of connections

  • ● overall

32

  • ● usable for PG communication

31

  • — reserved for PG communication

1

  • — adjustable for PG communication, min.

1

  • — adjustable for PG communication, max.

31

  • ● usable for OP communication

31

  • — reserved for OP communication

1

  • — adjustable for OP communication, min.

1

  • — adjustable for OP communication, max.

31

  • ● usable for S7 basic communication

30

  • — reserved for S7 basic communication

0

  • — adjustable for S7 basic communication, min.

0

  • — adjustable for S7 basic communication, max.

30

  • ● usable for S7 communication

16

  • — reserved for S7 communication

0

  • — adjustable for S7 communication, min.

0

  • — adjustable for S7 communication, max.

16

  • ● total number of instances, max.

32

  • ● usable for routing

X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.

S7 message functions

Number of login stations for message functions, max.

32; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4; without continuation

Status/control

  • ● Status/control variable

Yes

  • ● Variables

Inputs, outputs, memory bits, DB, times, counters

  • ● Number of variables, max.

30

  • — of which status variables, max.

30

  • — of which control variables, max.

14

Forcing

  • ● Forcing

Yes

  • ● Forcing, variables

Inputs, outputs

  • ● Number of variables, max.

10

Diagnostic buffer

  • ● present

Yes

  • ● Number of entries, max.

500

  • — adjustable

No

  • — of which powerfail-proof

100; Only the last 100 entries are retained

  • ● Number of entries readable in RUN, max.

499

  • — can be set

Yes; From 10 to 499

  • — preset

10

Service data

  • ● can be read out

Yes

Interrupts/diagnostics/status information

Alarms

No

Diagnostic functions

No

Diagnostics indication LED

  • ● Status indicator digital input (green)

Yes

  • ● Status indicator digital output (green)

Yes

Potential separation

Potential separation digital inputs

  • ● between the channels and backplane bus

Yes

Potential separation digital outputs

  • ● between the channels and backplane bus

Yes

Isolation

Isolation tested with

500 V DC

Ambient conditions

Ambient temperature during operation

  • ● min.

0 °C

  • ● max.

60 °C

Configuration

Configuration software

  • ● STEP 7

Yes; STEP 7 V5.5 SP2 or higher and S7-Technology Option Package V4.2 SP3, S7 F Configuration Pack V5.5 SP10, S7 Distributed Safety Option Package V5.4 SP5

Programming

  • ● Command set

see instruction list

  • ● Nesting levels

8

  • ● System functions (SFC)

see instruction list

  • ● System function blocks (SFB)

see instruction list

Programming language

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — CFC

Yes

  • — GRAPH

Yes

  • — HiGraph®

Yes

Know-how protection

  • ● User program protection/password protection

Yes

  • ● Block encryption

Yes; With S7 block Privacy

Dimensions

Width

120 mm

Height

125 mm

Depth

130 mm

Weights

Weight, approx.

640 g