SIEMENS SIMATIC HMI – SIMATIC MP 277 INOX

SIMATIC MP 277 INOX Overview

  • Multi Panels (MP) are deployed on-site – like Operator Panels – for machine operation and monitoring
  • Content of message buffer is retained even when panel is disconnected, without batteries
  • PLC functionality can be integrated directly into the MP 277 platform with Option
  • Their functionality can be expanded by installing additional Windows CE applications (Multi Panel and Panel options)
  • SIMATIC MP 277 devices on the basis of Windows CE combine the rugged construction of Operator Panels with the flexibility of PCs
  • Pixel graphics 10.4″ TFT display, color (64k colors)
  • Touch screen (analog/resistive)
  • The MP 277 INOX is available with stainless steel front (DIN EN 1672-2). These versions expand the application area of the Multi Panel 277 for special applications, ambient conditions, and special industries, e.g. in the food, beverages and tobacco industries.
  • All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET (Ethernet TCP/IP), are on-board

Product No. / Product DescriptionListprice / Your price
6AV6643-0ED01-2AX0
SIMATIC MP 277 10″ TOUCH STAINLESS STEEL FRONT, RETENTIV DISPLAY COVERED BY MEMBRANE, PROT. CL. FRONT IP66K, EX 2/22 10.4″ TFT DISPLAY, CONFIGURABLE WITH WINCC FLEXIBLE

Benefits

  • Integral component of Totally Integrated Automation (TIA):
    Increase of productivity, minimization of engineering overhead, reduction of lifecycle costs
  • Modular expansion with options such as:
    • WinAC MP for MP 277/software PLC
    • WinCC flexible/[email protected] for communication between different SIMATIC HMI systems
    • WinCC flexible/[email protected] for remote maintenance and servicing of machines/plants via the Internet/intranet
    • WinCC flexible/OPC Server for communication with applications from different manufacturers
    • Microsoft Pocket Internet Explorer (already included in scope of delivery)
    • IE6 for Win CE is integrated for WinCC flexible 2007 or higher.
    • WinCC flexible/ProAgent for selective and fast process fault diagnostics in systems and machines
    • WinCC flexible/Audit for user management (tracing and user operations)
  • Reduction of service and commissioning costs due to:
    • Backup/restore via Ethernet (TCP/IP), USB, MPI, PROFIBUS DP or optionally via SD/Multimedia Card
    • Remote download/upload of the configuration and firmware (remote = automatic transfer recognition)
    • Specific drivers can be reloaded
    • Long service life of the backlit display
  • Graphics library available with off-the-shelf picture objects
  • Can be used worldwide:
    • 32 languages can be configured (incl. Asian and Cyrillic character sets)
    • Up to 16 languages can be selected online
  • Standard hardware and software interfaces for increasing flexibility:
    • SD/MultimediaCard slot for memory expansions, backup/restore, or additional interfaces
    • Ethernet (TCP/IP) for central data and project management Ethernet; control link possible to SIMATIC S7
    • Standard Windows storage formats (CSV) for archives and recipes permits further processing using standard tools (e.g. MS Excel)

Application

They are used in the most diverse branches and applications and can be expanded in their applications with the Multi Panel options, e.g. for displaying HTML documents via the MS Pocket Internet Explorer.

The diskless and fanless design enables implementation in areas where high vibration or dust load limits the operation of a PC. Short boot-up times make the Multi Panels ready for operation sooner as well.

Design

  • Compact design with low mounting depth
  • The front is resistant to various oils, greases and standard detergents
  • Degree of protection IP66/NEMA 4x/NEMA 12 (front) or IP20 (rear)
  • Plug-in terminals for 24 V DC power supply
  • Interfaces:
    • RS 485/RS 422 interface for process connections (PPI, MPI, PROFIBUS DP up to 12 Mbit/s)
    • USB for memory stick, mouse, keyboard, printer, barcode reader, UPS and downloading/uploading the configuration
    • Ethernet (TCP/IP) for exchanging data with a higher-level PC, connection of a network printer and downloading/uploading the configuration; a control link to SIMATIC S7 is possible
  • Slot for SD/Multimedia Card

Integration

The MP 277 can in certain cases be connected simultaneously (multi-protocol capable) to:

  • SIMATIC S7-200/-300/-400
  • SIMATIC WinAC Software/Slot PLC
  • SIMATIC WinAC MP 2007
  • SIMATIC S5
  • SIMATIC 505
  • http communication with other SIMATIC HMI systems (optional with “WinCC flexible/[email protected]” option)
  • SIMOTION
  • SINUMERIK
    (optionally with “SINUMERIK HMI copy license WinCC flexible CE”; “SINUMERIK HMI Engineering package WinCC flexible” is additionally required for configuring;
  • For further information, see Catalog NC 60)
  • OPC XML Server (optionally with “WinCC flexible /OPC server”)
  • Third-party controllers
    • Allen Bradley
    • Mitsubishi
    • LG GLOFA GM
    • Modicon
    • GE-Fanuc
    • Omron
    • Telemecanique Uni-Telway
  • Via Ethernet (TCP/IP) to a higher-level PC, with enabled network printer

Note:

Further information can be found under “System interfaces”.

SIMATIC MP 277 INOX

Function

  • Display and modification of process parameters
  • Process display:
    • VGA resolution (640 x 480 pixels)
    • Each with 64k colors for pixels
    • Vector graphic (various line and plane objects)
    • Dynamic positioning and dynamic showing/hiding of objects
    • Pixel-graphic displays, trends and bar graph displays
    • Representation of up to 8 curves in a trend field;
  • Trend curve graphic with scroll and zoom functions for accessing the history and flexible selection of the representation period; read ruler for determining current values and displaying them in a table
    • Extensive symbol libraries (SIMATIC HMI Symbol Library)
    • Screen objects: slider, gauge, clock
    • Cyclic function processing using timers
  • Multiplex function for variables
  • Signaling system
    • Bit messages and analog messages (limit value messages)
    • Freely-definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of message events
    • Status and fault messages with message history
    • Non-volatile, maintenance-free message buffer
    • Message window and message line
  • Archiving of messages and process values (on CF/SD/Multimedia Card/USB flash drive, etc. or network drives via Ethernet)
    • Various archive types: Circulating and sequence archive
    • Storage of archive data in standard Windows format (CSV)
    • Online evaluation of process value archives through trend curves
    • External evaluation using standard tools (MS Excel, MS Access) is possible
  • Alarm log and shift log
  • Print functions (see “Recommended printers”)
  • Language switching
    • 16 online languages, 32 configuring languages, incl. Asian and Cyrillic character sets; language-dependent texts and graphics
  • Recipe management
    • With additional data storage (on SD/Multimedia Card)
    • Online/offline processing on the panel
    • Storage of recipe data in standard Windows format (CSV)
    • External processing using standard tools (Microsoft Excel and Access) is possible
  • TIA Runtime Functionalities
    • Direct keys (fast keys; with Key as keyboard image, with Touch freely customizable) used directly as PROFIBUS DP- or PROFINET IO input peripherals
    • For Key versions, LEDs additionally as output peripherals
    • In addition, message procedure Alarm S with SIMATIC S7 and SIMOTION
    • PG functionality STATUS FORCE-VAR in combination with SIMATIC S7
    • SIMATIC barcode scanner
    • Direct connection and evaluation of a SITOP UPS via USB
  • Display selection from the PLC
    supports operator prompting from the PLC
  • Display of HTML documents using MS Pocket Internet Explorer
  • Visual Basic Script, flexibility thanks to the implementation of new functions including linking to variables (comparison operations, loops, etc.)
  • Help texts
    for process screens, messages and variables
  • Arithmetic functions
  • Limit value monitoring
    for reliable process control of inputs and outputs
  • Permanent window;
    Fixed upper screen area for output of screen-independent information (e.g., important process variables, date and time-of-day)
  • Simple maintenance and configuration thanks to
    • Backup and restoring (Backup/Restore -> Image) of the complete (incl. license keys with WinCC flexible 2007 or higher) Panel on an SD/Multimedia Card (optional) possible, also through remote access ([email protected])
    • Save and load (Backup/Restore -> Image) complete panel (except License Key) on a PC
    • Download of configuration via Ethernet/USB/MPI/PROFIBUS DP/modem/http
    • Configuration upload via Ethernet/USB/MPI/PROFIBUS DP/modem/http; for downloading, the project is optionally compressed and transferred to the SD/multimedia card or USB flash drive (optional)
    • Automatic Transfer Recognition (Remote Transfer)
    • Configuration simulation directly on the configuration computer
    • Import/export of all texts incl. messages in CSV format for compiling using standard text processing programs
    • Centrally modifiable project-specific faceplates
  • Template
    • Creation of screen templates
    • Position-independent configuration of background objects
  • Password system
    • User-oriented access protection according to requirements of specific industries
    • Authentication with user ID and password
    • User group-specific rights
  • Service functions (optionally with “WinCC flexible /[email protected]”)
    • Email generation
    • Remote control of the SIMATIC HMI system based on Internet Explorer
    • Web server with status HTML pages and control functions
  • Client/server functions (optionally with “WinCC flexible /[email protected]”)
    • Remote operation and monitoring of other SIMATIC HMI systems
    • Plant-wide requests for information and archiving of process data
Configuration

Configuration is carried out with the SIMATIC WinCC flexible SP1 Standard or Advanced engineering software (see SIMATIC WinCC flexible HMI software/engineering software).

Projects (on previous panels) created using ProTool can be migrated to WinCC flexible.

Applications/options
  • WinAC MP software PLC for Multi Panels
    WinAC MP option for MP 277 (software PLC similar to performance class CPU 315)
    The I/O can be connected via Profibus DP

Note:

Utilization of the software PLC requires WinCC flexible 2007 or higher and MP 277 hardware with integrated retentive memory

  • WinCC flexible /[email protected];
    remote control and monitoring as well as communication between different SIMATIC HMI systems (see HMI software/Runtime software SIMATIC WinCC flexible /WinCC flexible RT options)
  • WinCC flexible /[email protected];
    remove maintenance and servicing for machines/plants via the Internet/intranet (see HMI software/Runtime software SIMATIC WinCC flexible/WinCC flexible RT options)
  • WinCC flexible /OPC-Server
    Communication with applications (e.g. MES, ERP, or office applications) of different manufacturers (see HMI software/Runtime software SIMATIC WinCC flexible/WinCC flexible RT options)
  • WinCC flexible /Audit
  • WinCC flexible /ProAgent
  • SINUMERIK

Technical specifications

Article number

6AV6643-0ED01-2AX0

MP277 10″ TOUCH INOX (EXPLOSION PROTECT)

General information

Customer-specific configuration

Yes

Display

Design of display

TFT

Screen diagonal

10.4 in

Color display

Yes

Number of colors

65 536

Resolution (pixels)

  • ● Horizontal image resolution

640 Pixel

  • ● Vertical image resolution

480 Pixel

Backlighting

  • ● MTBF backlighting (at 25 °C)

50 000 h

Control elements

Control elements

Touch screen

Keyboard fonts

  • ● System keys

No

  • ● alphanumeric keyboard

Yes

  • ● hexadecimal keyboard

Yes

Touch operation

  • ● Design as touch screen

Yes; analog, resistive

Installation type/mounting

Mounting position

vertical

maximum permissible angle of inclination without external ventilation

35°

Supply voltage

Type of supply voltage

DC

Processor

Processor type

ARM

Memory

Type of memory

Flash / RAM

Memory available for user data

6 Mbyte

Capacity of main memory, max.

128 Mbyte

Time of day

Clock

  • ● Type

Hardware clock, battery backup, synchronizable

  • ● retentive

Yes

  • ● synchronizable

Yes

Interfaces

Interfaces/bus type

1 x RS422, 1 x RS485, 1 x Ethernet (RJ45)

Number of RS 485 interfaces

1

Number of USB interfaces

2; Up to 1 GB respectively

Multimedia card/SD card slot

1x Multimedia Card slot, up to 128 MB

Industrial Ethernet

  • ● Industrial Ethernet interface

1 x Ethernet (RJ45)

Protocols

Supports protocol for PROFINET IO

Yes

PROFIsafe

No

PROFIBUS

Yes

Protocols (Ethernet)

  • ● TCP/IP

Yes

Further protocols

  • ● EtherNet/IP

No

  • ● MODBUS

Yes

  • ● other bus systems

Yes

Degree and class of protection

IP (at the front)

IP66K

NEMA (front)

NEMA 4x (when installed)

IP (rear)

IP20

Standards, approvals, certificates

Certifications

CE, FM Class I Div. 2, UL, CSA, cULus, EX-Zone 2, EX-Zone 22, NEMA 4x (Enclosure Type 4X, Type 12)

cULus

Yes

Suitable for safety functions

No

Use in hazardous areas

  • ● ATEX Zone 2

Yes

  • ● ATEX Zone 22

Yes

  • ● FM Class I Division 2

Yes

Ambient conditions

Ambient temperature during operation

  • ● min.

0 °C

  • ● max.

50 °C

Ambient temperature during storage/transportation

  • ● min.

-20 °C

  • ● max.

60 °C

Relative humidity

  • ● Operation, max.

90 %

Operating systems

pre-installed operating system

Windows CE

Configuration

Message indicator

Yes

Alarm system (incl. buffer and acknowledgment)

Yes

Process value display (output)

Yes

Process value default (input) possible

Yes

Recipe management

Yes

Configuration software

  • ● Configuration tool

WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately)

  • ● STEP 7 Basic (TIA Portal)

No

  • ● STEP 7 Professional (TIA Portal)

No

  • ● WinCC flexible Compact

No

  • ● WinCC flexible Standard

Yes

  • ● WinCC flexible Advanced

Yes

  • ● WinCC Basic (TIA Portal)

No

  • ● WinCC Comfort (TIA Portal)

Yes

  • ● WinCC Advanced (TIA Portal)

Yes

  • ● WinCC Professional (TIA Portal)

Yes

Languages

Online languages

  • ● Number of online/runtime languages

16

Project languages

  • ● Languages per project

32

Functionality under WinCC (TIA Portal)

Libraries

Yes

Task planner

Yes

Help system

Yes

  • ● Number of characters per info text

80

Message system

  • ● Number of alarm classes

32

  • ● Number of messages

4 000

  • ● Bit messages

Yes

  • — Number of bit messages

4 000

  • ● Analog messages

Yes

  • — Number of analog messages

200

  • ● System messages HMI

Yes

  • ● System messages PLC

Yes

  • ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)

Yes

  • ● Lines

1

  • ● Number of characters per message

80

  • ● Number of process values per message

8

  • ● Acknowledgment groups

Yes

  • ● Message indicator

Yes

  • ● First/last value

Yes

Recipe management

  • ● Number of recipes

300

  • ● Data records per recipe

500

  • ● Entries per data record

1 000

  • ● Recipe memory

64 KB integrated Flash, expandable

Variables

  • ● Number of variables per device

2 048

  • ● Number of variables per screen

200

  • ● Number of variables

1 000

  • ● Type Date & Time

2 048

  • ● Limit values

Yes

  • ● Multiplexing

Yes

  • ● Structures

Yes

Images

  • ● Number of configurable images

500

  • ● Permanent window/default

Yes

  • ● Start screen configurable

Yes

  • ● Image selection by PLC

Yes

  • ● Image number in the PLC

Yes

Image objects

  • ● Text objects

10,000 text elements

  • ● Number of I/O fields per image

200

  • ● Number of date/time fields

200

  • ● Return

Yes

  • ● Graphics object

Bit maps, icons, vector graphics

  • — Icons

1 000

Complex image objects

  • ● Status/control

With SIMATIC S7

  • ● dynamic objects

Diagrams, bar graphs, sliders, analog display, invisible buttons

  • — Number of objects per project

1 000

  • — Number of curve diagrams per image

10

  • ● Methods

Trend / profile

  • ● Bar graphs

  • — Number of bars per chart

10

  • ● Sliders

  • — Number of slides per image

10

  • ● Pointer instruments

  • — Number of analog indicators per image

10

  • ● Limit value lines

Yes

  • ● Number of alphanumerical fields

300

  • — alphanumeric fields per image

200

  • ● Number of numerical fields

2 048

  • — numerical fields per image

200

  • ● Number of password fields

2 048

  • ● Number of visible switches per project

200

  • — visible switches per image

200

  • — hidden switches per image

200

  • ● Number of status switches per project

200

  • — Number of status switches per image

200

  • ● Number of selector switches per project

200

  • — Selector switches per image

200

  • ● Number of decade switches per project

200

  • — Decade switches per image

200

  • ● Number of signal lamps per project

200

  • — Signal lamps per image

200

Attributes for dynamic objects

  • ● Color change

Yes

  • ● X/Y movement

Yes

  • ● Hide

Yes

Lists

  • ● Number of text lists per project

500

  • ● Number of text lists per image

200

  • ● Number of entries per text list

256

  • ● Number of graphics lists per project

400

  • ● Number of graphic lists per image

200

  • ● Number of entries per graphics list

256

Archiving

  • ● Number of archives per device

20

  • ● Number of measuring points per project

20

  • ● Number of entries per archive

10 000

  • ● Message archive

Yes

  • ● Process value archive

Yes

  • ● Archiving methods

  • — Sequential archive

Yes

  • — Short-term archive

Yes

  • ● Memory location

SD and MultiMediaCard

  • ● Data storage format

  • — CSV

Yes

  • ● Online evaluation

  • — using trend curves

Yes

Filters

  • ● cyclic

Yes

  • ● Tolerance

Yes

  • ● Change

Yes

Security

  • ● Number of user groups

50

  • ● Number of user rights

32

  • ● Password export/import

Yes

Logging through printer

  • ● Recording/Printing

Alarms, report (shift report), color print, hardcopy

Transfer (upload/download)

  • ● Transfer of configuration

MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition

Process coupling

  • ● Connection to controller

S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus) see chapter “System interfaces”

  • ● S7-1200

Yes

  • ● S7-1500

Yes

  • ● S7-200

Yes

  • — PPI (point-to-point)

Yes

  • — PPI network

Yes

  • — MPI

Yes

  • — PROFIBUS DP

Yes

  • — Ethernet

Yes

  • ● S7-300/400

Yes

  • — MPI

Yes

  • — PROFIBUS DP

Yes

  • — PROFINET

Yes

  • ● S5

Yes

  • — PROFIBUS DP

Yes

  • ● TI 505

Yes

  • ● Allen Bradley (DF1)

Yes

  • ● Allen Bradley (DF485)

Yes

  • ● Mitsubishi (FX)

Yes

  • ● Mitsubishi (MP4)

Yes

  • ● Telemecanique (Uni-Telway)

Yes

  • ● OMRON (LINK/Multilink)

Yes

  • ● Modicon (Modbus)

Yes

  • ● GE-Fanuc (SNP)

Yes

Functions

  • ● TAB sequence

Yes

  • ● Calculating functions

Yes

  • ● Animate

Yes

Service tools/configuration aids

  • ● Clean screen

Yes

  • ● Touch calibration

Yes

  • ● Backup/Restore manually

Yes

  • ● Simulation

Yes

  • ● Device switchover

Yes

  • ● Delta transfer

Yes

Expandability/openness

  • ● Open Platform Program

Yes

Peripherals/Options

Peripherals

Printer, barcode reader

  • ● SIMATIC HMI MM memory card: Multi Media Card

Yes

  • ● SIMATIC HMI SD memory card: Secure Digital memory card

Yes

  • ● USB memory

Yes

Additional software components loadable

Yes

Dimensions

Width of the housing front

325 mm

Height of housing front

263 mm

Overall depth

61 mm

Weights

Weight (without packaging)

4.2 kg

Other

free hotline

Yes

Warranty period

1 y

Dimensional drawings

All dimensions in mm. Tolerance ± 1 mm.