SIMATIC MP 377 INOX Overview

  • Multi Panels (MP) are deployed on-site – like Operator Panels – for machine operation and monitoring
  • Their functionality can be expanded by installing additional Windows CE applications (Multi Panel and Panel options)
  • SIMATIC MP 377 INOX devices on the basis of Windows CE combine the rugged construction of Operator Panels with the flexibility of PCs
  • PLC functionality can be integrated directly into the MP 377 platform with Option
  • Pixel graphics 15″ TFT display, color (64k colors)
  • Touch screen (analog/resistive)
  • The MP 377 INOX is available with a stainless steel front (DIN EN 1672-2). These models expand the application field of the Multi Panels 377 for specific uses, environmental conditions and for specific industries (e.g. food & beverage industry).
  • All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET (Ethernet TCP/IP), are on-board

Product No. / Product DescriptionListprice / Your price
6AV6644-0CB01-2AX0
SIMATIC MP 377 15″ TOUCH STAINLESS STEEL FRONT, RETENTIV DISPLAY COVERED BY MEMBRANE, PROT. CL. FRONT IP66K, EX 2/22 15″ TFT DISPLAY, CONFIGURABLE WITH WINCC FLEXIBLE

Benefits

  • Integral component of Totally Integrated Automation (TIA):
    Increase of productivity, minimization of engineering overhead, reduction of lifecycle costs
  • Modular expansion with options such as:
    • Software PLC SIMATIC WinAC MP
    • WinCC flexible/[email protected] for communication between different SIMATIC HMI systems
    • WinCC flexible/[email protected] for remote maintenance and servicing of machines/plants via the Internet/intranet
    • WinCC flexible/OPC Server for communication with applications from different manufacturers
    • MS Pocket Internet Explorer 6.0 (included in scope of delivery)
    • MS Multimedia Player (already included in the scope of delivery)
    • MS Viewer for Word, Excel and PDF files (already included in scope of delivery)
  • Reduction of service and commissioning costs due to:
    • Backup/restore via Ethernet (TCP/IP), USB, MPI, PROFIBUS DP or optionally via CF/SD/Multi Media Card
    • Remote download/upload of the configuration and firmware
    • Specific drivers can be reloaded
    • Long service life of the backlit display
  • Graphics library with preconfigured screen objects
  • Can be used worldwide:
    • 32 languages can be configured (incl. Asian and Cyrillic character sets)
    • Up to 16 languages can be selected online
  • Standard hardware and software interfaces for increasing flexibility:
    • CF Card slot and SD/Multimedia Card slot for language expansions, backup/restore
    • Ethernet (TCP/IP) for central data and project administration, and control interfacing to SIMATIC S7 possible
    • Standard Windows storage formats (CSV) for archives and recipes permits further processing using standard tools (e.g. MS Excel)

Application

The Multi Panels SIMATIC MP 377 INOX can be used wherever machines and systems are operated and monitored directly on-site – whether in production, process or building automation. These are used in the most popular branches and applications and can be expanded in their applications with the Multi Panel options, e.g. by displaying HTML documents via the Microsoft Pocket Internet Explorer.

Windows CE meets the basic prerequisites for application in rough industrial environments. The diskless and fanless design enables implementation in areas where high vibration or dust load limits the operation of a PC. Short boot-up times make the Multi Panels ready for operation sooner as well.

The Multi Panel 15″ Touch with stainless steel front is designed for all industries that require such a front. The front can be disinfected and does not affect the quality e.g. of foods (assuming regular cleaning). Cleaning can be carried out using pressurized water with a jet of 100 l/min at 1 bar from a distance of 2.5 to 3 m. Liquids flow off automatically from the front.

Design

  • Compact design with low mounting depth
  • The front is resistant to various oils, greases and standard detergents
  • Degree of protection IP66K/NEMA 4x/NEMA 12 (front) or IP20 (rear)
  • Plug-in terminals for 24 V DC power supply
  • Interfaces:
    • RS 485/RS 422 interface for process connections (MPI, PROFIBUS DP up to 12 Mbit/s)
    • USB for mouse, keyboard, printer, barcode reader and downloading/uploading the configuration
    • Ethernet (TCP/IP) for exchanging data with a higher-level PC, connection of a network printer and downloading/uploading the configuration; a control link to SIMATIC S7 is possible
  • Slot for CompactFlash card (CF card)
  • Slot for SD/Multimedia Card
  • Retentive memory for WinAC MP 377 data (data, timers, counters and bit memories)

Integration

The MP 377 can be connected to:

  • SIMATIC S7-200/-300/-400
  • SIMATIC WinAC Software/Slot PLC
  • Ethernet communication with SIMATIC S7
  • SIMATIC S5
  • SIMATIC 505
  • SINUMERIK
  • SIMOTION
  • Non-Siemens controllers:
    • Allen Bradley
    • Mitsubishi
    • Telemecanique
    • LG GLOFA GM
    • Modicon
    • GE-Fanuc
    • Omron
  • Over Ethernet (TCP/IP) to a higher-level PC, network printer
  • Multi-protocol capability
  • OPC XML Server (optionally with “WinCC flexible /OPC server”)
  • http communication with other SIMATIC HMI systems (optional with “WinCC flexible/[email protected]”)
  • SINUMERIK
    (optionally with “SINUMERIK HMI copy license WinCC flexible CE”; “SINUMERIK HMI engineering package WinCC flexible” is additionally required for configuration)

Function

  • Display and modification of process parameters
  • Process display:
    • Vector graphic (various line and plane objects)
    • Dynamic positioning and dynamic showing/hiding of objects
    • Pixel-graphic displays, trends and bar graph displays
    • Representation of up to 8 curves in a trend field;
    • Trend curve graphic with scroll and zoom functions for accessing the history and flexible selection of the representation period;
    • read ruler for determining current values and displaying them in a table
    • Extensive symbol libraries (SIMATIC HMI Symbol Library)
    • Screen objects: slider, gauge, clock
    • Cyclic function processing using timers
  • Multiplex function for variables
  • Signaling system
    • Discrete alarms and analog messages (limit value messages) as well as the Alarm S message frame procedure for SIMATIC S7 and SIMOTION
    • Freely-definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of message events
    • Status and fault messages with message history
    • Pre-configured message image, message window and message line
  • Archiving of messages and process values (on CF/SD/Multimedia Card/USB flash drive, etc. or network drives via Ethernet)
    • Various archive types: Circulating and sequence archive
    • Storage of archive data in standard Windows format (CSV)
    • Online evaluation of process value archives through trend curves
    • External evaluation using standard tools (MS Excel, MS Access) is possible
  • Alarm log and shift log
  • Print functions (see “Recommended printers”)
  • Language switching
    • 16 online languages, 32 configuration languages incl. Asian and Cyrillic character sets
  • Recipe management
    • With additional data storage (on CF/SD/Multimedia Card/USB flash drive, etc.)
    • Online/offline processing on the panel
    • Storage of recipe data in standard Windows format (CSV)
    • External processing using standard tools (Microsoft Excel and Access) is possible
  • Programming device functionality STATUS/ FORCE-VAR in conjunction with SIMATIC S5 and SIMATIC S7
  • Display selection from the PLC
    supports operator prompting from the PLC
  • Display of HTML documents using MS Pocket Internet Explorer
  • Visual Basic Script, flexibility thanks to the implementation of new functions including linking to variables (comparison operations, loops, etc.)
  • Help texts
    for process screens, messages and variables
  • Arithmetic functions
  • Limit value monitoring
    for reliable process control of inputs and outputs
  • Permanent window
    • Fixed area of screen for outputting non-screen-specific information (e.g. important process values, date and time)
    • Permanent window expanded by template concept for creating screen templates
  • Simple maintenance and configuration thanks to
    • Backup and restoring of configuration, operating system, data records, and firmware on an optional memory card (CF/SD/Multi Media Card) or via the Ethernet
    • Backup and restoration of the configuration, operating system, data records and firmware on a PC
    • Download/upload of configuration via Ethernet/USB/MPI/PROFIBUS DP/modem and CF or SD/Multimedia Card
    • Automatic transfer identification
    • Configuration simulation directly on the configuration computer
  • Import/export of all texts incl. messages in CSV format for compiling using standard text processing programs
  • Centrally modifiable project-specific faceplates
  • User administration (security)
    • User-oriented access protection according to requirements of specific industries
    • Authentication with user ID and password
    • User group-specific rights
  • Visual Basic Runtime object model
  • Service functions (optionally with “WinCC flexible /[email protected]”)
    • Email generation
    • Remote control of the SIMATIC HMI system based on Internet Explorer
    • Web server with status HTML pages and control functions
  • Client/server functions (optionally with “WinCC flexible /[email protected]”)
    • Remote operation and monitoring of other SIMATIC HMI systems
    • Plant-wide requests for information and archiving of process data
SIMATIC MP 377 INOX

Technical specifications

Article number

6AV6644-0CB01-2AX0

MP 377 15″ TOUCH INOX (EXPLOSION PROT.)

Display

Design of display

TFT

Screen diagonal

15 in

Color display

Yes

Number of colors

65 536

Resolution (pixels)

  • ● Horizontal image resolution

1 024 Pixel

  • ● Vertical image resolution

768 Pixel

Backlighting

  • ● MTBF backlighting (at 25 °C)

50 000 h

Control elements

Control elements

Touch screen

Keyboard fonts

  • ● Membrane keyboard

  • — user-definable label membrane keys

No

  • ● alphanumeric keyboard

Yes

  • ● hexadecimal keyboard

Yes

  • ● Multi-key operation

No

  • — Number of multi-key operations

0

Touch operation

  • ● Design as touch screen

Yes; analog, resistive

Installation type/mounting

maximum permissible angle of inclination without external ventilation

35°

Input current

Current consumption (rated value)

1.7 A; Typical

Starting current inrush I²t

4 A²·s

Power

Active power input, typ.

41 W

Memory

Type of memory

Flash / RAM

Memory available for user data

12 288 kbyte

Time of day

Clock

  • ● Type

Hardware clock, battery backup, synchronizable

  • ● retentive

Yes; via Goldkap for at least 6 weeks

  • ● synchronizable

Yes

Interfaces

Interfaces/bus type

1 x RS422, 1 x RS485, 2 x Ethernet (RJ45) (max. 12 Mbit/s)

Number of RS 485 interfaces

1

  • ● Transmission rate, max.

12 Mbit/s

Number of USB interfaces

2; Up to 1 GB respectively

PC card slot

No

CF card slot

1 x CF card slot

Multimedia card/SD card slot

1x Multimedia Card slot, up to 128 MB

Industrial Ethernet

  • ● Industrial Ethernet interface

2 x Ethernet (RJ45)

Protocols

PROFIBUS

Yes

MPI

Yes

Protocols (Ethernet)

  • ● TCP/IP

Yes

Protocols (terminal link)

Yes

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class A, for use in industrial areas

Yes

Degree and class of protection

IP (at the front)

IP66K

IP (rear)

IP20

Standards, approvals, certificates

Certifications

CE, FM Class I Div. 2, UL, cULus, EX Zone 2, EX Zone 22, C-TICK

cULus

Yes

EAC (formerly Gost-R)

No

EMC

The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation

Marine approval

  • ● Germanischer Lloyd (GL)

No

  • ● American Bureau of Shipping (ABS)

No

  • ● Bureau Veritas (BV)

No

  • ● Det Norske Veritas (DNV)

No

  • ● Lloyds Register of Shipping (LRS)

No

  • ● Polski Rejestr Statkow (PRS)

No

Use in hazardous areas

  • ● ATEX Zone 2

Yes

  • ● ATEX Zone 22

Yes

  • ● FM Class I Division 2

Yes

Ambient temperature during storage/transportation

  • ● min.

-20 °C

  • ● max.

60 °C

Relative humidity

  • ● Operation, max.

90 %

Operating systems

pre-installed operating system

Windows CE

Configuration

Message indicator

Yes

Alarm system (incl. buffer and acknowledgment)

Yes

Process value display (output)

Yes

Process value default (input) possible

Yes

Recipe management

Yes

Configuration software

  • ● Configuration tool

WinCC flexible Standard Version 2007 or higher (to be ordered separately)

  • ● STEP 7 Basic (TIA Portal)

No

  • ● STEP 7 Professional (TIA Portal)

No

  • ● WinCC flexible Compact

No

  • ● WinCC flexible Standard

Yes

  • ● WinCC flexible Advanced

Yes

  • ● WinCC Basic (TIA Portal)

No

  • ● WinCC Comfort (TIA Portal)

Yes

  • ● WinCC Advanced (TIA Portal)

Yes

  • ● WinCC Professional (TIA Portal)

Yes

Languages

Online languages

  • ● Number of online/runtime languages

16

Project languages

  • ● Languages per project

32

Functionality under WinCC (TIA Portal)

Libraries

Yes

Number of Visual Basic Scripts

  • ● Debugging in the simulator

No

Task planner

Yes

Help system

Yes

  • ● Number of characters per info text

70

  • ● Number of tooltips

0

Message system

  • ● Number of alarm classes

32

  • ● Number of messages

4 000

  • ● Bit messages

Yes

  • — Number of bit messages

4 000

  • ● Analog messages

Yes

  • — Number of analog messages

4 000

  • ● Telegram message procedure Alarm S

Yes

  • ● System messages HMI

Yes

  • ● System messages PLC

Yes

  • ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)

Yes

  • ● Lines

1

  • ● Number of characters per message

80

  • ● Number of process values per message

8

  • ● Acknowledgment groups

Yes

  • ● Message indicator

Yes

  • ● acoustic feedback

No

  • ● First/last value

Yes

Recipe management

  • ● Number of recipes

500

  • ● Data records per recipe

1 000

  • ● Entries per data record

1 000

  • ● Recipe memory

128 KB integrated Flash, expandable

Variables

  • ● Number of variables per device

4 096; Configuration with WinCC flexible 2008 and higher

  • ● Number of variables per screen

400

  • ● Number of variables

2 000

  • ● Initial values

2 048

  • ● Type Date & Time

2 048

  • ● Limit values

Yes

  • ● Multiplexing

Yes

  • ● Structures

Yes

Images

  • ● Number of configurable images

500

  • ● Permanent window/default

Yes

  • ● Start screen configurable

Yes

  • ● Image selection by PLC

Yes

  • ● Image number in the PLC

Yes

Image objects

  • ● Text objects

30000 text elements

  • ● Number of I/O fields per image

400

  • ● Number of date/time fields

400

  • ● Index of screen context

No

  • ● Return

Yes

  • ● Graphics object

Bit maps, icons, vector graphics

  • — Icons

2 000

  • — Icon (full screen)

0

Complex image objects

  • ● Status/control

With SIMATIC S7

  • ● dynamic objects

Diagrams, bar graphs, sliders, analog display, invisible buttons

  • — Number of objects per project

2 000

  • — Number of curve diagrams per image

20

  • ● Methods

Trend / profile

  • ● Bar graphs

  • — Number of bars per chart

20

  • ● Sliders

  • — Number of slides per image

20

  • ● Pointer instruments

  • — Number of analog indicators per image

20

  • ● Limit value lines

Yes

  • ● Number of alphanumerical fields

300

  • — alphanumeric fields per image

400

  • ● Number of numerical fields

2 048

  • — numerical fields per image

400

  • ● Number of password fields

2 048

  • ● Number of visible switches per project

400

  • — visible switches per image

400

  • — hidden switches per image

400

  • ● Number of status switches per project

400

  • — Number of status switches per image

400

  • ● Number of selector switches per project

400

  • — Selector switches per image

400

  • ● Number of decade switches per project

0

  • — Decade switches per image

0

  • ● Number of signal lamps per project

400

  • — Signal lamps per image

400

Attributes for dynamic objects

  • ● Color change

Yes

  • ● X/Y movement

Yes

  • ● Hide

Yes

  • ● Angle of rotation

No

Lists

  • ● Number of text lists per project

500

  • ● Number of text lists per image

400

  • ● Number of entries per text list

256

  • ● Number of graphics lists per project

500

  • ● Number of graphic lists per image

400

  • ● Number of entries per graphics list

256

Archiving

  • ● Number of archives per device

50

  • ● Number of measuring points per project

50

  • ● Number of entries per archive

50 000

  • ● Message archive

Yes

  • ● Process value archive

Yes

  • ● Archiving methods

Yes

  • — Sequential archive

Yes

  • — Short-term archive

Yes

  • ● Memory location

Yes

  • — CF card

Yes

  • — USB memory

No

  • — Ethernet

Yes

  • ● Data storage format

Yes

  • — CSV

Yes

  • — TXT

No

  • ● external evaluation

Yes

  • ● Size of archive

Yes

  • ● Online evaluation

Yes

  • — using trend curves

Yes

Filters

  • ● cyclic

Yes

  • ● Tolerance

Yes

  • ● Change

Yes

Security

  • ● Number of user groups

50

  • ● Number of user rights

32

  • ● Password export/import

Yes

Data carrier support

  • ● PC card

No

  • ● CF card

Yes

  • ● Hard disk

Yes; Only USB hard disks with external power supply

Logging through printer

  • ● Recording/Printing

Alarms, report (shift report), color print, hardcopy

Transfer (upload/download)

  • ● Transfer of configuration

MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition

Process coupling

  • ● Connection to controller

S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter “System interfaces”

  • ● S7-1200

Yes

  • ● S7-1500

Yes

  • ● S7-200

Yes

  • — PPI (point-to-point)

Yes

  • — PPI network

Yes

  • — MPI

Yes

  • — PROFIBUS DP

Yes

  • ● S7-300/400

Yes

  • — MPI

Yes

  • — PROFIBUS DP

Yes

  • — PROFINET

Yes

  • ● S5

Yes

  • — serial

No

  • — PROFIBUS DP

Yes

  • ● TI 505

Yes

  • ● Allen Bradley (DF1)

Yes

  • ● Allen Bradley (DF485)

Yes

  • ● Mitsubishi (FX)

Yes

  • ● Mitsubishi (MP4)

Yes

  • ● Telemecanique (ADJUST)

No

  • ● Telemecanique (Uni-Telway)

Yes

  • ● OMRON (LINK/Multilink)

Yes

  • ● Modicon (Modbus)

Yes

  • ● GE-Fanuc (SNP)

Yes

Functions

  • ● Key repeat

No

  • ● TAB sequence

Yes

  • ● Calculating functions

Yes

  • ● Animate

Yes

  • ● Menu tree editor

No

  • ● Unit switchover

No

Service tools/configuration aids

  • ● Clean screen

Yes

  • ● Touch calibration

Yes

  • ● Backup/Restore manually

Yes

  • ● Simulation

Yes

  • ● Device switchover

Yes

  • ● Delta transfer

Yes

  • ● Monitoring function for battery and memory

Yes

  • ● Trace (operation archive)

No

Expandability/openness

  • ● Open Platform Program

Yes

Peripherals/Options

Peripherals

Printer, card reader, barcode reader

  • ● SIMATIC HMI MM memory card: Multi Media Card

Yes

  • ● SIMATIC HMI SD memory card: Secure Digital memory card

Yes

  • ● USB memory

Yes

Additional software components loadable

Yes

Dimensions

Width of the housing front

400 mm

Height of housing front

310 mm

Overall depth

75 mm

Weights

Weight (without packaging)

6.2 kg

Dimensional drawings

SIMATIC MP 377 15″ Touch with stainless steel front