SIEMENS SIMATIC S7-1500 COMPACT CPU CPU 1512C-1 PN

CPU 1512C-1 PN

  • The compact CPU with integral digital and analog inputs and outputs in the product spectrum of the S7-1500 Controllers
  • With integrated technological functions, e.g. high-speed counter (HSC), frequency measurement, period duration measurement or stepper motor control, pulse duration modulation, frequency output
  • Suitable for applications with medium requirements for program scope and processing speed
  • Used as central controller in production lines with central and distributed I/O
  • PROFINET IO IRT interface with 2-port switch
  • PROFINET IO Controller for operating distributed I/O on PROFINET
  • PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET IO Controller
  • OPC UA Server (Data Access) as runtime option for the easy connection of SIMATIC S7-1500 to third-party devices/systems
  • Isochronous mode
  • Integrated motion control functionalities for controlling speed-controlled and positioning axes, support for external encoders, cams/cam tracks and probes
  • Integrated web server for diagnostics with the option of creating user-defined web pages

Note

SIMATIC Memory Card required for operation of the CPU.

Product No. / Product DescriptionListprice / Your price
6ES7512-1CK00-0AB0
SIMATIC S7-1500 COMPACT CPU CPU 1512C-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 250 KB FOR PROGRAM AND 1 MB FOR DATA, 32 DIGITAL INPUTS, 32 DIGITAL OUTPUTS, 5 ANALOG INPUTS, 2 ANALOG OUTPUTS, 6 HIGH SPEED COUNTERS, 4 HIGH SPEED COUNTERS FOR PTO/PWM/FREQUENZY OUTPUT 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 48 NS BIT-PERFORMANCE, INCL. FRONT CONNECTOR PUSH-IN, SIMATIC MEMORY CARD NECESSARY

Application

The CPU 1512C-1 PN is the compact CPU for applications with medium requirements for processing speed and speed of response in discrete production technology.

The CPU 1512C-1 PN has 5 analog inputs, via which the analog process signals, such as pressure or temperature, can be acquired. Of these, four inputs can be used for current or voltage measurement and one input for resistance measurement.
The analog outputs integrated directly on the CPU convert a 16-bit digital value into a current or a voltage and output this to the process. They are suitable for controlling proportional valves, for example.
By means of the 32 integrated digital inputs, 24 V DC signals from plant the can be recorded directly on the controller.
The 32 integrated digital outputs switch 24 V DC voltages and thus transfer internal signals from the controller to the plant.
The integrated counters offer the possibility of recording signals as fast as 100 kHz and evaluating the counter status or the current speed directly in the controller without the need for additional modules. The speed can be output as a frequency or period, or as a user-normalized speed.
The motion control functions of the CPU can use the counters as an actual position value and the analog outputs as a setpoint speed output. The 4 to 100 kHz outputs can be used to:

  • Directly control stepper motors
  • Output frequencies

or, via the PWM function:

  • Directly control valves or,
  • Digitally transmit analog signals

In addition, the CPU offers comprehensive control functionalities via easy-to-configure blocks as well as the ability to connect drives via standardized PLC-open blocks.

The CPU 1512C-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 2-port switch so that a linear topology can be set up in the system.

Design

The CPU 1512C-1 PN features:

  • A powerful processor:
    The CPU achieves command execution times as low as 60 ns per binary instruction.
  • A large work memory:
    250 KB for program, 1 MB for data.
  • Integrated inputs/outputs;
    32 digital inputs and 32 digital outputs as well as 5 analog inputs and 2 analog outputs for current/voltage signals and an additional input for measuring temperature on the CPU.
  • SIMATIC Memory Cards as load memory:
    permit additional functions such as datalog and archives
  • Flexible expansion capability:
    single-tier configuration with max. 32 modules (CPU + 31 modules)
  • Display with functions for:
    • Displaying overview information such as IP address of the integrated interface, station name, plant designation, location identifier, etc.
    • Display and acknowledgment of diagnostic and user messages
    • Display of module information
    • Display of a user-definable logo
    • Showing display settings
    • Setting IP addresses
    • Setting the date and time
    • Selecting the operating mode
    • Resetting the CPU to factory settings
    • Backup and restoring of the project
    • Disabling/enabling the display
    • Enabling protection levels
  • PROFINET IO IRT interface:
    For connecting distributed I/O via PROFINET

Function

Performance

  • Faster command processing, depending on the CPU type, language extensions and new data types.
  • Even shorter response times of the CPUs due to considerably faster backplane bus.
  • Powerful network connection:
    each CPU is equipped with PROFINET IO IRT (2-port switch) as a standard interface.
  • Integrated technology
    • Connection of analog and PROFIdrive-capable drives via standardized blocks (PLCopen).
    • Support of speed-controlled and positioning axes as well as external encoders, precise position gearing between axes, cams/cam tracks and probes.
    • Integrated I/O, e.g. for the direct operation of stepper motors and analog axes or for the direct recording of HTL encoders.
    • Design of the counter functions in the configuration and programming compatible with the TM Count 2x24V module.
    • Trace functions for all CPU tags, both for diagnostics in real time as well as for sporadic error detection.
    • Comprehensive control functionalities, e.g. easily configurable blocks for automatic optimization of the control parameters for optimum control quality.
  • Security Integrated
    • Password-based know-how protection against unauthorized read-out and modification of program blocks.
    • Copy protection for tying individual blocks to the serial number of the SIMATIC Memory Card: The block can only run if the configured memory card is inserted in the CPU.
    • 4-level authorization concept:
      Communication with the HMI devices can also be restricted.
    • Manipulation protection:
      The controller recognizes modified or unauthorized transmissions of the engineering data.
  • Design and handling
    • Display of the overview information:
      e.g. station name, plant identifier, location designation, etc., diagnostic information, module information, display settings.
    • Operator control options on the display:
      Set addresses of the CPU or connected Ethernet communications processors, set date and time, select operating mode of CPU, reset CPU to factory settings, disable/enable display, activate protection levels, acknowledge messages, backup and restoring of the project.
  • Integrated system diagnostics
    • System diagnostics information is displayed consistently and in plain text in the display, TIA Portal, HMI devices and Web server, even for messages from the drives, and updated even if the CPU is in STOP mode.
    • Integrated into the firmware of the CPU, no special configuration is required
  • SIMATIC Memory Card (required for operation of the CPU)
    • Used as a plug-in load memory or for updating the firmware.
    • Also for storing additional documents or csv files (for recipes and archives)
    • Creation of data blocks for storage/reading of data via SFCs of the user program
  • Datalog (archives) and recipes
    • Storage of csv files for recipes and archives on the SIMATIC Memory Card;
      easy access to plant-relevant operating data using Office tools or via a Web server
    • Easy access to machine configuration data by means of a Web browser or SD card reader (two-way data exchange from and to the controller)
  • Programming
    • Programming with STEP 7 Professional, V13 SP 1 UPD 4 or higher
    • Migration tool for migrating from SIMATIC S7-300/S7-400 to S7-1500, converts the program code largely automatically. Non-convertible code is logged and can be manually adapted.
    • S7-1200 basic programs can be transferred to the S7-1500 by copying and pasting.

Technical specifications

Article number

6ES7512-1CK00-0AB0

CPU 1512C-1 PN, 250 KB PROG, 1 MB DATA

General information

Product type designation

CPU 1512C-1 PN

HW functional status

FS03

Firmware version

V2.1

Engineering with

  • ● STEP 7 TIA Portal configurable/integrated as of version

V14 SP1 (FW V2.1) / V13 SP1 Update 4 (FW V1.8) or higher

Configuration control

via dataset

Yes

Display

Screen diagonal [cm]

3.45 cm

Control elements

Number of keys

6

Mode selector switch

1

Supply voltage

Type of supply voltage

24 V DC

permissible range, lower limit (DC)

19.2 V; 20.4 V DC, for supplying the digital inputs/outputs

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

Mains buffering

  • ● Mains/voltage failure stored energy time

5 ms; Refers to the power supply on the CPU section

Input current

Current consumption (rated value)

0.8 A; Digital onboard I/O modules are supplied separately

Inrush current, max.

1.9 A; Rated value

I²t

0.34 A²·s

Digital inputs

  • ● from load voltage L+ (without load), max.

20 mA; per group

Digital outputs

  • ● from load voltage L+, max.

30 mA; Per group, without load

Output voltage

Rated value (DC)

24 V

Encoder supply

Number of outputs

2; One common 24 V encoder supply per 16 digital inputs

24 V encoder supply

  • ● 24 V

Yes; L+ (-0.8 V)

  • ● Short-circuit protection

Yes

  • ● Output current, max.

1 A

Power

Infeed power to the backplane bus

10 W

Power consumption from the backplane bus (balanced)

9 W

Power loss

Power loss, typ.

15.2 W

Memory

Number of slots for SIMATIC memory card

1

SIMATIC memory card required

Yes

Work memory

  • ● integrated (for program)

250 kbyte

  • ● integrated (for data)

1 Mbyte

Load memory

  • ● Plug-in (SIMATIC Memory Card), max.

32 Gbyte

Backup

  • ● maintenance-free

Yes

CPU processing times

for bit operations, typ.

48 ns

for word operations, typ.

58 ns

for fixed point arithmetic, typ.

77 ns

for floating point arithmetic, typ.

307 ns

CPU-blocks

Number of elements (total)

2 000; Blocks (OB, FB, FC, DB) and UDTs

DB

  • ● Number range

1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999

  • ● Size, max.

1 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB

FB

  • ● Number range

0 … 65 535

  • ● Size, max.

250 kbyte

FC

  • ● Number range

0 … 65 535

  • ● Size, max.

250 kbyte

OB

  • ● Size, max.

250 kbyte

  • ● Number of free cycle OBs

100

  • ● Number of time alarm OBs

20

  • ● Number of delay alarm OBs

20

  • ● Number of cyclic interrupt OBs

20; With minimum OB 3x cycle of 500 µs

  • ● Number of process alarm OBs

50

  • ● Number of DPV1 alarm OBs

3

  • ● Number of isochronous mode OBs

1

  • ● Number of technology synchronous alarm OBs

2

  • ● Number of startup OBs

100

  • ● Number of asynchronous error OBs

4

  • ● Number of synchronous error OBs

2

  • ● Number of diagnostic alarm OBs

1

Nesting depth

  • ● per priority class

24

Counters, timers and their retentivity

S7 counter

  • ● Number

2 048

Retentivity

  • — adjustable

Yes

IEC counter

  • ● Number

Any (only limited by the main memory)

Retentivity

  • — adjustable

Yes

S7 times

  • ● Number

2 048

Retentivity

  • — adjustable

Yes

IEC timer

  • ● Number

Any (only limited by the main memory)

Retentivity

  • — adjustable

Yes

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max.

128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB

Extended retentive data area (incl. timers, counters, flags), max.

1 Mbyte; When using PS 60W 24/48/60V DC HF

Flag

  • ● Number, max.

16 kbyte

  • ● Number of clock memories

8; 8 clock memory bits, grouped into one clock memory byte

Data blocks

  • ● Retentivity adjustable

Yes

  • ● Retentivity preset

No

Local data

  • ● per priority class, max.

64 kbyte; max. 16 KB per block

Address area

Number of IO modules

2 048; max. number of modules / submodules

I/O address area

  • ● Inputs

32 kbyte; All inputs are in the process image

  • ● Outputs

32 kbyte; All outputs are in the process image

per integrated IO subsystem

  • — Inputs (volume)

8 kbyte

  • — Outputs (volume)

8 kbyte

per CM/CP

  • — Inputs (volume)

8 kbyte

  • — Outputs (volume)

8 kbyte

Subprocess images

  • ● Number of subprocess images, max.

32

Hardware configuration

Number of distributed IO systems

32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)

Number of DP masters

  • ● Via CM

6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total

Number of IO Controllers

  • ● integrated

1

  • ● Via CM

6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total

Rack

  • ● Modules per rack, max.

32; CPU + 31 modules

  • ● Number of lines, max.

1

PtP CM

  • ● Number of PtP CMs

the number of connectable PtP CMs is only limited by the number of available slots

Time of day

Clock

  • ● Type

Hardware clock

  • ● Backup time

6 wk; At 40 °C ambient temperature, typically

  • ● Deviation per day, max.

10 s; Typ.: 2 s

Operating hours counter

  • ● Number

16

Clock synchronization

  • ● supported

Yes

  • ● in AS, master

Yes

  • ● in AS, slave

Yes

  • ● on Ethernet via NTP

Yes

Digital inputs

integrated channels (DI)

32

Digital inputs, parameterizable

Yes

Source/sink input

P-reading

Input characteristic curve in accordance with IEC 61131, type 3

Yes

Digital input functions, parameterizable

  • ● Gate start/stop

Yes

  • ● Capture

Yes

  • ● Synchronization

Yes

Input voltage

  • ● Type of input voltage

DC

  • ● Rated value (DC)

24 V

  • ● for signal “0”

-3 to +5V

  • ● for signal “1”

+11 to +30V

Input current

  • ● for signal “1”, typ.

2.5 mA

Input delay (for rated value of input voltage)

for standard inputs

  • — parameterizable

Yes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms

  • — at “0” to “1”, min.

4 µs; for parameterization “none”

  • — at “0” to “1”, max.

20 ms

  • — at “1” to “0”, min.

4 µs; for parameterization “none”

  • — at “1” to “0”, max.

20 ms

for interrupt inputs

  • — parameterizable

Yes; Same as for standard inputs

for counter/technological functions

  • — parameterizable

Yes; Same as for standard inputs

Cable length

  • ● shielded, max.

1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz

  • ● unshielded, max.

600 m; For technological functions: No

Digital outputs

Type of digital output

Transistor

integrated channels (DO)

32

Current-sourcing

Yes; Push-pull output

Short-circuit protection

Yes; electronic/thermal

  • ● Response threshold, typ.

1.6 A with standard output, 0.5 A with high-speed output; see manual for details

Limitation of inductive shutdown voltage to

-0.8 V

Controlling a digital input

Yes

Accuracy of pulse duration

Up to ±100 ppm ±2 μs at high-speed output; see manual for details

minimum pulse duration

2 µs; With High Speed output

Digital output functions, parameterizable

  • ● Switching tripped by comparison values

Yes; As output signal of a high-speed counter

  • ● PWM output

Yes

  • — Number, max.

4

  • — Cycle duration, parameterizable

Yes

  • — ON period, min.

0 %

  • — ON period, max.

100 %

  • — Resolution of the duty cycle

0.0036 %; For S7 analog format, min. 40 ns

  • ● Frequency output

Yes

  • ● Pulse train

Yes; also for pulse/direction interface

Switching capacity of the outputs

  • ● with resistive load, max.

0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details

  • ● on lamp load, max.

5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details

Load resistance range

  • ● lower limit

48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details

  • ● upper limit

12 kΩ

Output voltage

  • ● Type of output voltage

DC

  • ● for signal “0”, max.

1 V; With high-speed output, i.e. when using a high-speed output; see manual for details

  • ● for signal “1”, min.

23.2 V; L+ (-0.8 V)

Output current

  • ● for signal “1” rated value

0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details

  • ● for signal “1” permissible range, min.

2 mA

  • ● for signal “1” permissible range, max.

0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details

  • ● for signal “0” residual current, max.

0.5 mA

Output delay with resistive load

  • ● “0” to “1”, max.

200 µs

  • ● “1” to “0”, max.

500 µs; Load-dependent

for technological functions

  • — “0” to “1”, max.

5 µs; Depending on the output used, see additional description in manual

  • — “1” to “0”, max.

5 µs; Depending on the output used, see additional description in manual

Parallel switching of two outputs

  • ● for logic links

Yes; For technological functions: No

  • ● for uprating

No

  • ● for redundant control of a load

Yes; For technological functions: No

Switching frequency

  • ● with resistive load, max.

100 kHz; For high-speed output, 100 Hz for standard output

  • ● with inductive load, max.

0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve

  • ● on lamp load, max.

10 Hz

Total current of the outputs

  • ● Current per channel, max.

0.5 A; see additional description in the manual

  • ● Current per group, max.

8 A; see additional description in the manual

  • ● Current per power supply, max.

4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual

for technological functions

  • — Current per channel, max.

0.5 A; see additional description in the manual

Cable length

  • ● shielded, max.

1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz

  • ● unshielded, max.

600 m; For technological functions: No

Analog inputs

Number of analog inputs

5; 4x for U/I, 1x for R/RTD

  • ● For current measurement

4; max.

  • ● For voltage measurement

4; max.

  • ● For resistance/resistance thermometer measurement

1

permissible input voltage for voltage input (destruction limit), max.

28.8 V

permissible input current for current input (destruction limit), max.

40 mA

Cycle time (all channels), min.

1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual

Technical unit for temperature measurement adjustable

Yes; °C/°F/K

Input ranges (rated values), voltages

  • ● 0 to +10 V

Yes; Physical measuring range: ± 10 V

  • ● Input resistance (0 to 10 V)

100 kΩ

  • ● 1 V to 5 V

Yes; Physical measuring range: ± 10 V

  • ● Input resistance (1 V to 5 V)

100 kΩ

  • ● -10 V to +10 V

Yes

  • ● Input resistance (-10 V to +10 V)

100 kΩ

  • ● -5 V to +5 V

Yes; Physical measuring range: ± 10 V

  • ● Input resistance (-5 V to +5 V)

100 kΩ

Input ranges (rated values), currents

  • ● 0 to 20 mA

Yes; Physical measuring range: ± 20 mA

  • ● Input resistance (0 to 20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

  • ● -20 mA to +20 mA

Yes

  • ● Input resistance (-20 mA to +20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

  • ● 4 mA to 20 mA

Yes; Physical measuring range: ± 20 mA

  • ● Input resistance (4 mA to 20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

Input ranges (rated values), resistance thermometer

  • ● Ni 100

Yes; Standard/climate

  • ● Input resistance (Ni 100)

10 MΩ

  • ● Pt 100

Yes; Standard/climate

  • ● Input resistance (Pt 100)

10 MΩ

Input ranges (rated values), resistors

  • ● 0 to 150 ohms

Yes; Physical measuring range: 0 … 600 ohms

  • ● Input resistance (0 to 150 ohms)

10 MΩ

  • ● 0 to 300 ohms

Yes; Physical measuring range: 0 … 600 ohms

  • ● Input resistance (0 to 300 ohms)

10 MΩ

  • ● 0 to 600 ohms

Yes

  • ● Input resistance (0 to 600 ohms)

10 MΩ

Cable length

  • ● shielded, max.

800 m; for U/I, 200 m for R/RTD

Analog outputs

integrated channels (AO)

2

Voltage output, short-circuit protection

Yes

Cycle time (all channels), min.

1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual

Output ranges, voltage

  • ● 0 to 10 V

Yes

  • ● 1 V to 5 V

Yes

  • ● -10 V to +10 V

Yes

Output ranges, current

  • ● 0 to 20 mA

Yes

  • ● -20 mA to +20 mA

Yes

  • ● 4 mA to 20 mA

Yes

Load impedance (in rated range of output)

  • ● with voltage outputs, min.

1 kΩ

  • ● with voltage outputs, capacitive load, max.

100 nF

  • ● with current outputs, max.

500 Ω

  • ● with current outputs, inductive load, max.

1 mH

Cable length

  • ● shielded, max.

200 m

Analog value generation for the inputs

Integration and conversion time/resolution per channel

  • ● Resolution with overrange (bit including sign), max.

16 bit

  • ● Integration time, parameterizable

Yes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels

  • ● Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 / 10

Smoothing of measured values

  • ● parameterizable

Yes

  • ● Step: None

Yes

  • ● Step: low

Yes

  • ● Step: Medium

Yes

  • ● Step: High

Yes

Analog value generation for the outputs

Integration and conversion time/resolution per channel

  • ● Resolution with overrange (bit including sign), max.

16 bit

Settling time

  • ● for resistive load

1.5 ms

  • ● for capacitive load

2.5 ms

  • ● for inductive load

2.5 ms

Encoder

Connection of signal encoders

  • ● for voltage measurement

Yes

  • ● for current measurement as 4-wire transducer

Yes

  • ● for resistance measurement with two-wire connection

Yes

  • ● for resistance measurement with three-wire connection

Yes

  • ● for resistance measurement with four-wire connection

Yes

Connectable encoders

  • ● 2-wire sensor

Yes

  • — permissible quiescent current (2-wire sensor), max.

1.5 mA

Encoder signals, incremental encoder (asymmetrical)

  • ● Input voltage

24 V

  • ● Input frequency, max.

100 kHz

  • ● Counting frequency, max.

400 kHz; with quadruple evaluation

  • ● Signal filter, parameterizable

Yes

  • ● Incremental encoder with A/B tracks, 90° phase offset

Yes

  • ● Incremental encoder with A/B tracks, 90° phase offset and zero track

Yes

  • ● Pulse encoder

Yes

  • ● Pulse encoder with direction

Yes

  • ● Pulse encoder with one impulse signal per count direction

Yes

Errors/accuracies

Linearity error (relative to input range), (+/-)

0.1 %

Temperature error (relative to input range), (+/-)

0.005 %/K

Crosstalk between the inputs, max.

-60 dB

Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)

0.05 %

Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)

0.02 %

Linearity error (relative to output range), (+/-)

0.15 %

Temperature error (relative to output range), (+/-)

0.005 %/K

Crosstalk between the outputs, max.

-80 dB

Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)

0.05 %

Operational error limit in overall temperature range

  • ● Voltage, relative to input range, (+/-)

0.3 %

  • ● Current, relative to input range, (+/-)

0.3 %

  • ● Resistance, relative to input range, (+/-)

0.3 %

  • ● Resistance thermometer, relative to input range, (+/-)

Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K

  • ● Voltage, relative to output range, (+/-)

0.3 %

  • ● Current, relative to output range, (+/-)

0.3 %

Basic error limit (operational limit at 25 °C)

  • ● Voltage, relative to input range, (+/-)

0.2 %

  • ● Current, relative to input range, (+/-)

0.2 %

  • ● Resistance, relative to input range, (+/-)

0.2 %

  • ● Resistance thermometer, relative to input range, (+/-)

Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K

  • ● Voltage, relative to output range, (+/-)

0.2 %

  • ● Current, relative to output range, (+/-)

0.2 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

  • ● Series mode interference (peak value of interference < rated value of input range), min.

30 dB

  • ● Common mode voltage, max.

10 V

  • ● Common mode interference, min.

60 dB; at 400 Hz: 50 dB

Interfaces

Number of PROFINET interfaces

1

1. Interface

Interface types

  • ● Number of ports

2

  • ● integrated switch

Yes

  • ● RJ 45 (Ethernet)

Yes; X1

Functionality

  • ● IP protocol

Yes; IPv4

  • ● PROFINET IO Controller

Yes

  • ● PROFINET IO Device

Yes

  • ● SIMATIC communication

Yes

  • ● Open IE communication

Yes

  • ● Web server

Yes

  • ● Media redundancy

Yes

PROFINET IO Controller

Services

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Isochronous mode

Yes

  • — Open IE communication

Yes

  • — IRT

Yes

  • — MRP

Yes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50

  • — MRPD

Yes; Requirement: IRT

  • — Prioritized startup

Yes; Max. 32 PROFINET devices

  • — Number of connectable IO Devices, max.

128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET

  • — Of which IO devices with IRT, max.

64

  • — Number of connectable IO Devices for RT, max.

128

  • — of which in line, max.

128

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8; in total across all interfaces

  • — Number of IO Devices per tool, max.

8

  • — Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

  • — for send cycle of 250 µs

250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

  • — for send cycle of 500 µs

500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

  • — for send cycle of 1 ms

1 ms to 16 ms

  • — for send cycle of 2 ms

2 ms to 32 ms

  • — for send cycle of 4 ms

4 ms to 64 ms

  • — With IRT and parameterization of “odd” send cycles

Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs)

Update time for RT

  • — for send cycle of 250 µs

250 µs to 128 ms

  • — for send cycle of 500 µs

500 µs to 256 ms

  • — for send cycle of 1 ms

1 ms to 512 ms

  • — for send cycle of 2 ms

2 ms to 512 ms

  • — for send cycle of 4 ms

4 ms to 512 ms

PROFINET IO Device

Services

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Isochronous mode

No

  • — Open IE communication

Yes

  • — IRT

Yes

  • — MRP

Yes

  • — MRPD

Yes; Requirement: IRT

  • — PROFIenergy

Yes

  • — Shared device

Yes

  • — Number of IO Controllers with shared device, max.

4

Interface types

RJ 45 (Ethernet)

  • ● 100 Mbps

Yes

  • ● Autonegotiation

Yes

  • ● Autocrossing

Yes

  • ● Industrial Ethernet status LED

Yes

Protocols

Number of connections

  • ● Number of connections, max.

128; via integrated interfaces of the CPU and connected CPs / CMs

  • ● Number of connections reserved for ES/HMI/web

10

  • ● Number of connections via integrated interfaces

88

  • ● Number of S7 routing paths

16

PROFINET IO Controller

Services

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Isochronous mode

Yes

  • — Open IE communication

Yes

  • — IRT

Yes

  • — MRP

Yes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50

  • — MRPD

Yes; Requirement: IRT

  • — PROFIenergy

Yes

  • — Prioritized startup

Yes; Max. 32 PROFINET devices

  • — Number of connectable IO Devices, max.

128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET

  • — Of which IO devices with IRT, max.

64

  • — Number of connectable IO Devices for RT, max.

128

  • — of which in line, max.

128

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8; in total across all interfaces

  • — Number of IO Devices per tool, max.

8

  • — Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

SIMATIC communication

  • ● S7 communication, as server

Yes

  • ● S7 communication, as client

Yes

  • ● User data per job, max.

See online help (S7 communication, user data size)

Open IE communication

  • ● TCP/IP

Yes

  • — Data length, max.

64 kbyte

  • — several passive connections per port, supported

Yes

  • ● ISO-on-TCP (RFC1006)

Yes

  • — Data length, max.

64 kbyte

  • ● UDP

Yes

  • — Data length, max.

1 472 byte

  • — UDP multicast

Yes; Max. 5 multicast circuits

  • ● DHCP

No

  • ● SNMP

Yes

  • ● DCP

Yes

  • ● LLDP

Yes

Web server

  • ● HTTP

Yes; Standard and user pages

  • ● HTTPS

Yes; Standard and user pages

OPC UA

  • ● OPC UA Server

Yes; Data access (read, write, subscribe), runtime license required

  • — Application authentication

Yes

  • — Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — User authentication

“anonymous” or by user name & password

Further protocols

  • ● MODBUS

Yes; MODBUS TCP

Media redundancy

  • ● Switchover time on line break, typ.

200 ms; For MRP, bumpless for MRPD

  • ● Number of stations in the ring, max.

50

Isochronous mode

Isochronous operation (application synchronized up to terminal)

Yes; With minimum OB 6x cycle of 625 µs

Equidistance

Yes

S7 message functions

Number of login stations for message functions, max.

32

Program alarms

Yes

Number of configurable program alarms

5 000

Number of simultaneously active program alarms

  • ● Number of program alarms

300

  • ● Number of alarms for system diagnostics

100

  • ● Number of alarms for motion technology objects

80

Test commissioning functions

Joint commission (Team Engineering)

Yes; Parallel online access possible for up to 5 engineering systems

Status block

Yes; Up to 8 simultaneously (in total across all ES clients)

Single step

No

Status/control

  • ● Status/control variable

Yes

  • ● Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

  • ● Number of variables, max.

  • — of which status variables, max.

200; per job

  • — of which control variables, max.

200; per job

Forcing

  • ● Forcing, variables

Peripheral inputs/outputs

  • ● Number of variables, max.

200

Diagnostic buffer

  • ● present

Yes

  • ● Number of entries, max.

1 000

  • — of which powerfail-proof

500

Traces

  • ● Number of configurable Traces

4; Up to 512 KB of data per trace are possible

Interrupts/diagnostics/status information

Alarms

  • ● Diagnostic alarm

Yes

  • ● Hardware interrupt

Yes

Diagnostic messages

  • ● Monitoring the supply voltage

Yes

  • ● Wire-break

Yes; for analog inputs/outputs, see description in manual

  • ● Short-circuit

Yes; for analog outputs, see description in manual

  • ● A/B transition error at incremental encoder

Yes

Diagnostics indication LED

  • ● RUN/STOP LED

Yes

  • ● ERROR LED

Yes

  • ● MAINT LED

Yes

  • ● Monitoring of the supply voltage (PWR-LED)

Yes

  • ● Channel status display

Yes

  • ● for channel diagnostics

Yes; For analog inputs/outputs

  • ● Connection display LINK TX/RX

Yes

Supported technology objects

Motion Control

Yes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER

  • ● Number of available Motion Control resources for technology objects (except cam disks)

800

  • ● Required Motion Control resources

  • — per speed-controlled axis

40

  • — per positioning axis

80

  • — per synchronous axis

160

  • — per external encoder

80

  • — per output cam

20

  • — per cam track

160

  • — per probe

40

  • ● Positioning axis

  • — Number of positioning axes at motion control cycle of 4 ms (typical value)

5

  • — Number of positioning axes at motion control cycle of 8 ms (typical value)

10

Controller

  • ● PID_Compact

Yes; Universal PID controller with integrated optimization

  • ● PID_3Step

Yes; PID controller with integrated optimization for valves

  • ● PID-Temp

Yes; PID controller with integrated optimization for temperature

Counting and measuring

  • ● High-speed counter

Yes

Integrated Functions

Number of counters

6

Counting frequency (counter) max.

400 kHz; with quadruple evaluation

Counting functions

  • ● Continuous counting

Yes

  • ● Counter response parameterizable

Yes

  • ● Hardware gate via digital input

Yes

  • ● Software gate

Yes

  • ● Event-controlled stop

Yes

  • ● Synchronization via digital input

Yes

  • ● Counting range, parameterizable

Yes

Comparator

  • — Number of comparators

2; per count channel; see manual for details

  • — Direction dependency

Yes

  • — Can be changed from user program

Yes

Position detection

  • ● Incremental acquisition

Yes

  • ● Suitable for S7-1500 Motion Control

Yes

Measuring functions

  • ● Measuring time, parameterizable

Yes

  • ● Dynamic measurement period adjustment

Yes

  • ● Number of thresholds, parameterizable

2

Measuring range

  • — Frequency measurement, min.

0.04 Hz

  • — Frequency measurement, max.

400 kHz; with quadruple evaluation

  • — Cycle duration measurement, min.

2.5 µs

  • — Cycle duration measurement, max.

25 s

Accuracy

  • — Frequency measurement

100 ppm; depending on measuring interval and signal evaluation

  • — Cycle duration measurement

100 ppm; depending on measuring interval and signal evaluation

  • — Velocity measurement

100 ppm; depending on measuring interval and signal evaluation

Potential separation

Potential separation digital inputs

  • ● between the channels

No

  • ● between the channels, in groups of

16

Potential separation digital outputs

  • ● between the channels

No

  • ● between the channels, in groups of

16

Potential separation channels

  • ● between the channels and backplane bus

Yes

  • ● Between the channels and load voltage L+

No

Isolation

Isolation tested with

707 V DC (type test)

Ambient conditions

Ambient temperature during operation

  • ● horizontal installation, min.

0 °C

  • ● horizontal installation, max.

60 °C; Note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off

  • ● vertical installation, min.

0 °C

  • ● vertical installation, max.

40 °C; Note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off

Ambient temperature during storage/transportation

  • ● min.

-40 °C

  • ● max.

70 °C

Configuration

Programming

Programming language

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — GRAPH

Yes

Know-how protection

  • ● User program protection/password protection

Yes

  • ● Copy protection

Yes

  • ● Block protection

Yes

Access protection

  • ● Password for display

Yes

  • ● Protection level: Write protection

Yes

  • ● Protection level: Read/write protection

Yes

  • ● Protection level: Complete protection

Yes

Cycle time monitoring

  • ● lower limit

adjustable minimum cycle time

  • ● upper limit

adjustable maximum cycle time

Dimensions

Width

110 mm

Height

147 mm

Depth

129 mm

Weights

Weight, approx.

1 360 g

Popular Products Series

GE QuickPanel family of Human Machine Interfaces Ge Fanuc HMI

AoteWell Sell all models of the popular GE IP QuickPanel family…

Mitsubishi F740 Series Frequency Inverter

The FR-F700 Series was launched in 2004 as the successor to the FR-F500 Series VFD. With growing market demands for energy saving inverters in building automation, water processing and HVAC industries, the FR-F700 was able to exceed power-saving expectations in fan and pump applications by incorporating “OEC” (optimum excitation control) which combined maximum drive utilization with minimal power consumption.

Siemens PLC spare part 6AV 6DD 6SN 6ES5 6ES7

Main supply Siemens 6ES7 6AV6 6AV3 6SE7 Spare parts...

Allen-Bradley 6176M Standard Industrial Monitors

Allen-Bradley 6176M Standard Industrial Monitors
6176M Standard Monitors are flat panel industrial color monitors for use in less demanding environments. All Standard Monitors have USB and RS232 touch screen inputs, DVI and VGA video inputs, and an On Screen Display (OSD) that enables image rotation, color pallet changes, and push button auto reset.

Allen-Bradley 6186M Performance Monitors

Simatic S7-200 Smart PLC

SIEMNES SIMATIC S7-200 Smart, newly launched micro PLC Product, is designed to suit the needs of developing markets that are under constant pressure due to price and demands for continuous performance. Providing an excellent performance – to – price ratio, SIMATIC S7 200 SMART when combined with other smart drive products from Siemens helps in building a cost effective yet efficient automation Solution.