PC-based visualization software for single-user systems directly at the machine.

  • Runs on Windows 7 Professional, Ultimate, Enterprise and Windows 10 Professional, Enterprise
  • Current version: SIMATIC WinCC flexible 2008 SP5 Runtime

SIMATIC WinCC flexible Runtime is configured with the SIMATIC WinCC flexible Advanced configuration software.

Product No. / Product Description SIEMENS SIMATIC WinCC flexible RT Ordering data
6AV6613-1BA51-3CA0
WINCC FLEXIBLE 2008 RUNTIME 128 POWER TAGS RUNTIME SW, SINGLE LICENSE SW AND DOCUMENTATION ON CD LICENSE KEY ON USB STICK, EXECUTABLE UNDER WINDOWS 7 PROF/ULTIMATE/ENTERPRICE(32/64) WINDOWS10 PROF/ENTERPRICE (64)
6AV6613-1DA51-3CA0
WINCC FLEXIBLE 2008 RUNTIME 512 POWER TAGS RUNTIME SW, SINGLE LICENSE SW AND DOCUMENTATION ON CD LICENSE KEY ON USB STICK, EXECUTABLE UNDER WINDOWS 7 PROF/ULTIMATE/ENTERPRICE(32/64) WINDOWS10 PROF/ENTERPRICE (64)
6AV6613-1FA51-3CA0
WINCC FLEXIBLE 2008 RUNTIME 2048 POWER TAGS RUNTIME SW, SINGLE LICENSE SW AND DOCUMENTATION ON CD LICENSE KEY ON USB STICK, EXECUTABLE UNDER WINDOWS 7 PROF/ULTIMATE/ENTERPRICE(32/64) WINDOWS10 PROF/ENTERPRICE (64)
6AV6613-1GA51-3CA0
WINCC FLEXIBLE 2008 RUNTIME 4096 POWER TAGS RUNTIME SW, SINGLE LICENSE SW AND DOCUMENTATION ON CD LICENSE KEY ON USB STICK, EXECUTABLE UNDER WINDOWS 7 PROF/ULTIMATE/ENTERPRICE(32/64) WINDOWS10 PROF/ENTERPRICE (64)
6AV6613-1XA51-3CE0
WINCC FLEXIBLE 2008 RUNTIME, UPGRADE FOR WINCC FLEXIBLE 2004/2005/2007 RUNTIME, INCL. [email protected]/[email protected]/ OPC-SERVER/ARCHIVES/RECIPES/ PROAGENT/AUDIT FOR WINCC FLEXIBLE RUNTIME, RUNTIME SW, SINGLE LICENSE SW AND DOCUMENTATION ON CD LICENSE KEY ON USB STICK, EXECUTABLE UNDER WINDOWS7 PROF/ULTIMATE/ENTERPRICE(32/64) WINDOWS10 PROF/ENTERPRICE (64)

Application

SIMATIC WinCC flexible Runtime is the high-performance visualization software for simple visualization tasks at machine level. It can be used as a single-user solution for all automation applications in factory automation, process automation and building services automation.

SIMATIC WinCC flexible Runtime can be used in combination with the following operator panels:

  • SIMATIC Panel PCs
    • PC IL 70/77
    • Microbox 420
    • Panel PCs 477/477B/477C
    • Panel PCs 577/577B/577C
    • Panel PCs 670/677/677B/677C
    • Panel PCs 870/877
  • SINUMERIK Panel PCs
    • HT8; OP08T
    • OP010, OP012, OP015
    • TP012, TP015, OP015A
  • Standard PCs with resolutions (W x H in pixels) of:
    • 4:3 format: 640 x 480, 800 x 600, 1 024 x 768, 1 280 x 1 024, 1 600 x 1 200
    • Widescreen format: 800 x 480, 1 280 x 800, 1 366 x 768, 1 440 x 900, 1 680 x 1 050, 1 920 x 1 080, 1 920 x 1 200, 1 980 x 1 080

Design

SIMATIC WinCC flexible Runtime is available as a software package with 128, 512, 2048 or 4096 PowerTags. The term PowerTags is used exclusively to identify process variables and range pointers that have a process link to the controller. Variables without process link, constant limit values of variables, and messages (up to 4000 bit-triggered messages) are also available for additional system performance.

The range of functions of WinCC flexible Runtime includes the centralized HMI components for visualizing and reporting, and it can be expanded to suit requirements and costs by using optional packages.

SIMATIC WinCC flexible Runtime is configured with the SIMATIC WinCC flexible Advanced configuration software.


Function

System requirements

WinCC flexible Runtime

Operating system

  • Windows 7 Professional / Ultimate /Enterprise (32-bit and 64-bit)
  • Windows 7 Embedded Standard, Standard with SP1 (32-bit) 1)
  • Windows 10 Professional, Enterprise, LTSB Enterprise
  • Windows 10 IoT LTSB Enterprise 1)

Processor 4)

  • Minimum

Windows 7: 1 GHz

  • Recommended

Windows 7: ≥ 1 GHz

Graphics

  • Minimum

SVGA

  • Resolution

640 x 480 to 1600 x 1200 or 800 x 480 to 1980 x 1080

RAM 2)

  • Minimum

Windows 7: 1 GB

  • Recommended

Windows 7: ≥ 1 GB

Hard disk (free memory space) 3)

≥ 250 MB

1) Only on approved systems such as SIMATIC IPCs. For more detailed information, please contact your Siemens contact person

2) RAM requirements are determined primarily by the size of the graphics used.

3) Without taking archives into account.
In addition to the space needed by WinCC flexible, Windows also requires space on the hard disk; e.g., for the swap file. The following formula has proven itself in the past: The size of the swap file = 3 x the size of the RAM. For further information, refer to your Windows documentation

4) More powerful systems (Pentium 4 and higher) may be required in order to use options


Integration

SIMATIC WinCC flexible Runtime supports linking to:

Protocol

PC interfaces

SIMATIC S5 via AS511 (TTY)

S5-90U

COM1/COM2 13)

S5-90U

S5-100U (CPU 100, 102, 103)

S5-115U (CPU 941, 942, 943, 944, 945)

S5-135U (CPU 928A, 928B)

S5-155U (CPU 946/947, 948)

SIMATIC S5 via PROFIBUS DP 1)

S5-95U/L2-DP master

CP 5512 2)

S5-115U (CPU 941, 942, 943, 944, 945)

S5-135U (CPU 928A, 928B)

S5-155U (CPU 946/947, 948)

SIMATIC S7 via PPI

S7-200

CP 5612
CP 5621 1)

CP 5622
CP 5613 A3
CP 5614 A3
CP 5623
CP 5624
CP 5711
PC/PPI adapter 3)

SIMATIC S7 via MPI

S7-200 (except CPU 212) 4)

CP 5612
CP 5621 1)
CP 5622
CP 5613 A3
CP 5614 A3
CP 5623
CP 5624
CP 5711
PC adapter USB A2 6)
Teleservice V6.1

S7-300

S7-400

WinAC Basis (V3.0 and higher)

WinAC RTX

SIMATIC S7 via PROFIBUS DP 5)

S7-215 4)

CP 5612
CP 5621 1)
CP 5622
CP 5613 A3
CP 5614 A3
CP 5623
CP 5624
CP 5711

S7-300 CPUs with integral PROFIBUS-SS

S7-300 with CP 342-5

S7-400 CPUs with integral PROFIBUS-SS

S7-400 with CP 443-5 or IM 467

WinAC Basis (V3.0 and higher)

WinAC RTX

SIMATIC S7 via Ethernet (TCP/IP)

S7-200 with CP 243-1

CP 1612 A2 7) 
CP 1613 A2

S7-300 CPUs with integral Ethernet interface

S7-300 with CP 343-1

S7-400 CPUs with integral Ethernet interface

S7-400 with CP 443-1

WinAC Basis (V3.0 and higher)

WinAC RTX

SIMATIC S7 via integrated interface

WinAC Basis (V2.0 and higher)

Internal system interface

WinAC RTX

SIMATIC 505 NITP

SIMATIC 500/505 RS 232/RS 422

COM1/COM2

SIMATIC 505 via PROFIBUS DP

SIMATIC 545/555 with CP 5434

CP 5612 2)
CP 5622 2)

SIMOTION 8)

SINUMERIK 9)

Third-party controllers

Allen Bradley (DF1/DH485)

COM1/COM2

Allen Bradley (Ethernet)

CP 1612 A2 7)

GE Fanuc (SNP/SNPX)

COM1/COM2

LG GLOFA GM

COM1/COM2

Mitsubishi (FX/MP4)

COM1/COM2

Modicon (Modbus)

COM1/COM2

Modicon (Modbus TCP/IP)

CP 1612 A2 7)

OMRON (Link/Multilink)

COM1/COM2

OPC 10)  12)

Data Access V2.05a (client + server)

CP 1612 A2 7)

Data Access XML V1.00 (client)

HTTP communication for data exchange between SIMATIC HMI (client + server) 11) 12)

CP 1612 A2 7)

1) WinCC flexible Runtime is passive (DP slave); the function block required for the link is included in the scope of delivery of WinCC flexible

2) For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface

3) Only point-to-point to S7-200; no configuration download, operating systems: Windows XP; Article number: 6ES7901-3CB30-0AX0

4) Constraint with regard to baud rate for S7-200; see Catalog ST 70

5) WinCC flexible RT is active; communication with S7 functions

6) Only point-to-point to S7-300/-400; no configuration download, operating systems: Windows XP or higher; article number: 6GK1571-0BA00-0AA0 (USB)

7) For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet interface

8) For further information, see Catalog PM 21

9) “SINUMERIK HMI copy license OA” option required; for further information, see Catalog NC 60

10) OPC Client is included in scope of delivery, the “WinCC flexible/OPC Server for WinCC flexible Runtime” license is required for the OPC Server option

11) “WinCC flexible/[email protected] for WinCC flexible Runtime” license required

12) OPC and HTTP communication are additive, i.e. can be used in conjunction with the PLC links listed above

13) Via PC cable with integrated level converter RS 232/TTY; Article number: 6ES5734-1BD20

For information about SIMATIC Panels that support OPC/http communication, see the overview under “System interfaces”.

Application note

In parallel with each and every PLC link, WinCC flexible Runtime supports the use of the OPC Client channel; this enables, for example, connection to an SNMP OPC Server for the purpose of visualizing the data stored there. The SNMP OPC Server provides a means of monitoring network components of any type (e.g. switches) which support the SNMP protocol. For further information, see Catalog IK PI.

Note:
For further information, see “Operator Control and Monitoring Devices/System interfaces”

SIMATIC WinCC flexible Runtime application example


Technical specifications

Type

SIMATIC WinCC flexible Runtime

The specifications are maximum values

Displays

500

  • Fields per screen

400

  • Variables per screen

400

  • Static text

30,000

  • Graphics objects

2,000

  • Complex objects per display (e.g. bars)

40

  • Trends

800

  • Graphics lists 1)

500

  • Text lists 1)

500

  • Number of entries in symbol tables

3,500

Variables

4,096 3)

Messages bit-triggered / analog

4,000 / 500

  • Message text (number of characters)

80

  • Number of process values per message

8

  • Size of message buffer

1,024

  • Pending message events

500

Archives 4)

100

  • Archivable data

Process data,
messages

  • Max. number of entries per archive (incl. all archive segments)

500,000

  • Archive types

Short-term archive, sequence archive (max. 400 per archive)

  • Data storage format

CSV (Comma Separated Variable),
RDB (Runtime Data Base),
interface to MS SQL database

Recipes4)

1,000

  • Elements per recipe

2,000 3)

  • Data records per recipe

5,000 2)

Password protection

  • User rights

32

  • Number of user groups

50

Visual Basic scripts

200

Online languages, max.

16

Communication

SIMATIC S7 MPI interface/
PROFIBUS DP interface

  • Number of connectable stations, max.

Depending on the scope of the configuration (communication) from the point of view of WinCC flexible Runtime, as many as 8 connections are possible

SIMATIC S7 PPI interface

  • Number of connectable stations, max.

1 from viewpoint of WinCC flexible Runtime

SIMATIC S5
PROFIBUS DP interface

  • Number of connectable stations, max.

1 from viewpoint of WinCC flexible Runtime

Multi-protocol operation

Yes, OPC Client or SIMATIC HMI HTTP protocol are additive, i.e. can be used in conjunction with other PLC links

1) Together only 500 text and graphics lists

2) Dependent on memory medium used

3) Dependent on number of licensed PowerTags

4) Option for SIMATIC WinCC flexible Runtime. For further information, refer to “WinCC flexible options”.