SIEMENS SIPLUS LOGO! modular expansion modules

SIPLUS LOGO! modular expansion modules

Overview

  • Expansion modules for connection to LOGO! modular
  • With digital inputs and outputs, analog inputs, or analog outputs
Note:

SIPLUS LOGO! 6 versions are not compatible with SIPLUS LOGO! 8.

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were adopted from the respective standard products. SIPLUS extreme specific information was added.

SIPLUS LOGO! modular expansion modules Ordering data

Product No. / Product DescriptionListprice / Your price
6AG1055-1CB00-2BY0
SIPLUS LOGO! DM8 24 -40 … +70 DEGREES C BASED ON 6ED1055-1CB00-0BA0
6AG1055-1CB00-7BA2
SIPLUS LOGO! DM8 24 -40 … +70 DEGREES C STARTUP -25 DEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1CB00-0BA2 . EXPANSION MODULE, PU/I/O: 24V/24V/TRANS., 4 DI/4 DO FOR LOGO! 8
6AG1055-1FB00-2BY1
SIPLUS LOGO! DM8 230R -40 … +70 DEGREES C BASED ON 6ED1055-1FB00-0BA1
6AG1055-1FB00-7BA2
SIPLUS LOGO! DM8 230V -40 … +70 DEGREES C STARTUP -25 DEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1FB00-0BA2 . EXP. MODULE, PU/I/O: 230V/230V/RELAIS, 2TE, 4 DI/4 DO FOR LOGO! 8
6AG1055-1HB00-2BY0
SIPLUS LOGO! DM8 24R -40 … +70 DEGREES C BASED ON 6ED1055-1HB00-0BA0
6AG1055-1HB00-7BA2
SIPLUS LOGO! DM8 24R -40 … +70 DEGREES C STARTUP -25 GDEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1HB00-0BA2 . EXPANSION MODULE, PU/I/O: 24V/24V/RELAY, 2TE 4 DI/4 DO, AC/DC/NPN INPUT FOR LOGO! 8
6AG1055-1MA00-2BY0
SIPLUS LOGO! AM2 – 40 … +70 DEGREES C with conformal coating BASED ON 6ED1055-1MA00-0BA0
6AG1055-1MA00-7BA2
SIPLUS LOGO! AM2 -40 … +70 DEGREES C STARTUP -25 GDEGREES C MIT CONFORMAL COATING BASED ON 6ED1055-1MA00-0BA2 . EXPANSION MODULE, PU: DC 12/24V, 2 AI, 0 – 10V OR 0/4 – 20MA FOR LOGO! 8
6AG1055-1MB00-2BY1
SIPLUS LOGO! DM8 12/24R -40 … +70 DEGREES C BASED ON 6ED1055-1MB00-0BA1
6AG1055-1MB00-7BA2
SIPLUS LOGO! DM8 12/24R -40 … +70 DEGREES C STARTUP -25 DEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1MB00-0BA2 . EXP. MODULE PU/I/O: 12, 24V/12V/24V/RELAIS, 2TE, 4 DI/4 DO FOR LOGO! 8
Product No. / Product DescriptionListprice / Your price
6AG1055-1MM00-2BY1
SIPLUS LOGO! AM2 AQ -40 … +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1MM00-0BA1 . EXPAN. MODULE, PS: DC 24V, 2AQ, 0-10V, 0/4-20MA
6AG1055-1MM00-7BA2
SIPLUS LOGO! AM2 AQ -40 … +70 DEGREES C STARTUP -25 GDEGREES C WITH CONFORMAL COATING BASED ON 6ED1055-1MM00-0BA2 . EXPAN. MODULE, PU: DC 24V, 0/4-20MA 2AQ, 0-10V FOR LOGO! 8
6AG1055-1NB10-2BA0
SIPLUS LOGO! DM16 24R -25 … +70 DGR C BASED ON 6ED1055-1NB10-0BA0
6AG1055-1NB10-7BA2
SIPLUS LOGO! DM16 24R -40 … +70 DEGREES C STARTUP -25 DEGREES C MIT CONFORMAL COATING BASED ON 6ED1055-1NB10-0BA2 . EXP. MODULE, PU/I/O: 24V DC/24V DC/RELAY, 8 DI/8 DO, 4TE FOR LOGO! 8
6AG1055-1PB00-2BY0
SIPLUS LOGO! DM8 12/24 -40 … +70 DEGREES C BASED ON 6ED1055-1CB00-0BA0

Design

  • Relay outputs with max. 5 A output current.
  • Different modules:
    • 4 digital inputs, 4 digital outputs or
    • 4 digital inputs, 4 relay outputs or
    • 2 analog inputs or
    • 2 analog outputs.
  • Interface for connection to LOGO! modular logic modules.

Note on compatibility:

Expansion modules for LOGO! 8 can only be used on LOGO! 8 basic devices!

Expansion modules for LOGO! 6 and 7 cannot be used with LOGO! 8 basic devices.

Technical specifications

Article number

6AG1055-1CB00-7BA2

6AG1055-1HB00-7BA2

6AG1055-1MB00-7BA2

SIPLUS LOGO! DM8 24 V8

SIPLUS LOGO! DM8 24R V8

SIPLUS LOGO! DM8 12/24R V8

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 12 V DC

Yes

  • ● 24 V DC

Yes

Yes

Yes

permissible range, lower limit (DC)

20.4 V

20.4 V

10.8 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

Rated value (AC)

  • ● 24 V AC

Yes

Line frequency

  • ● permissible range, lower limit

47 Hz

  • ● permissible range, upper limit

63 Hz

Digital inputs

Number of digital inputs

4

4

4

Input voltage

  • ● Type of input voltage

DC

AC/DC

DC

  • ● for signal “0”

< 5 V DC

< 5 V AC/DC

< 5 V DC

  • ● for signal “1”

> 12 V DC

> 12 V AC/DC

> 8.5 V

Input current

  • ● for signal “0”, max. (permissible quiescent current)

0.88 mA

1.1 mA

0.88 mA

  • ● for signal “1”, typ.

4 mA

5.5 mA

4.2 mA

Input delay (for rated value of input voltage)

for standard inputs

  • — at “0” to “1”, max.

1.5 ms

1.5 ms

1.5 ms

  • — at “1” to “0”, max.

1.5 ms

15 ms

1.5 ms

Digital outputs

Number of digital outputs

4

4; Relays

4; Relays

Short-circuit protection

Yes

No

No

Controlling a digital input

Yes

Yes

Switching capacity of the outputs

  • ● on lamp load, max.

1 000 W

1 000 W

Output current

  • ● for signal “1” rated value

0.3 A

5 A

5 A

  • ● for signal “1” minimum load current

100 mA

100 mA

Parallel switching of two outputs

  • ● for uprating

No

No

No

Switching frequency

  • ● with resistive load, max.

10 Hz

2 Hz

2 Hz

  • ● with inductive load, max.

0.5 Hz

0.5 Hz

0.5 Hz

  • ● mechanical, max.

10 Hz

10 Hz

Relay outputs

Switching capacity of contacts

  • — with inductive load, max.

3 A

3 A

  • — with resistive load, max.

5 A

5 A

  • — Thermal continuous current, max.

0.3 A

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Yes

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Yes

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

CSA approval

No

UL approval

No

FM approval

Yes

No

developed in accordance with IEC 61131

Yes

Yes

Yes

according to VDE 0631

Yes

Yes

Marine approval

Yes

No

Yes

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ● max.

70 °C; Tmax; Tmax > +55 °C max. load 0.2 A per output

70 °C; = Tmax; Tmax > +55 °C max. load 3 A per relay or max. total current 10 A

70 °C; = Tmax; Tmax > +55 °C max. load 3 A per relay or max. total current 10 A

  • ● At cold restart, min.

-25 °C

-25 °C

-25 °C

Ambient temperature during storage/transportation

  • ● min.

-40 °C

-40 °C

-40 °C

  • ● max.

70 °C

70 °C

70 °C

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Dimensions

Width

35.5 mm

35.5 mm

35.5 mm

Height

90 mm

90 mm

90 mm

Depth

58 mm

58 mm

58 mm

Article number

6AG1055-1FB00-7BA2

6AG1055-1NB10-7BA2

SIPLUS LOGO! DM8 230R V8

SIPLUS LOGO! DM16 24R V8

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 4 spacing units wide

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes

  • ● 115 V DC

Yes

  • ● 230 V DC

Yes

permissible range, lower limit (DC)

100 V

20.4 V

permissible range, upper limit (DC)

253 V

28.8 V

Rated value (AC)

  • ● 24 V AC

No

  • ● 115 V AC

Yes

  • ● 230 V AC

Yes

Line frequency

  • ● permissible range, lower limit

47 Hz

  • ● permissible range, upper limit

63 Hz

Digital inputs

Number of digital inputs

4

8

Input voltage

  • ● Type of input voltage

AC/DC

DC

  • ● for signal “0”

< 40 V AC, < 30 V DC

< 5 V DC

  • ● for signal “1”

> 79 V AC, > 79 V DC

> 12 V DC

Input current

  • ● for signal “0”, max. (permissible quiescent current)

0.06 mA; 0.05 mA with AC, 0.06 mA with DC

0.85 mA

  • ● for signal “1”, typ.

0.37 mA

3.5 mA

Input delay (for rated value of input voltage)

for standard inputs

  • — at “0” to “1”, max.

40 ms

1.5 ms

  • — at “1” to “0”, max.

75 ms

1.5 ms

Digital outputs

Number of digital outputs

4; Relays

8; Relays

Short-circuit protection

No

No

Controlling a digital input

Yes

Yes

Switching capacity of the outputs

  • ● on lamp load, max.

1 000 W; 500 W at 115V AC

1 000 W

Output current

  • ● for signal “1” rated value

5 A

5 A

  • ● for signal “1” minimum load current

100 mA

100 mA

Parallel switching of two outputs

  • ● for uprating

No

No

Switching frequency

  • ● with resistive load, max.

2 Hz

2 Hz

  • ● with inductive load, max.

0.5 Hz

0.5 Hz

  • ● mechanical, max.

10 Hz

10 Hz

Relay outputs

Switching capacity of contacts

  • — with inductive load, max.

3 A

3 A

  • — with resistive load, max.

5 A

5 A

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

CSA approval

No

UL approval

No

FM approval

No

developed in accordance with IEC 61131

Yes

Yes

according to VDE 0631

Yes

Yes

Marine approval

No

Yes

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin; Startup @ -25 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ● max.

70 °C; = Tmax; Tmax > +55 °C max. load 3 A per relay or max. total current 10 A

70 °C; = Tmax; Tmax > +55 °C max. load 3 A per relay

  • ● At cold restart, min.

-25 °C

-25 °C

Ambient temperature during storage/transportation

  • ● min.

-40 °C

-40 °C

  • ● max.

70 °C

70 °C

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Dimensions

Width

35.5 mm

71.5 mm

Height

90 mm

90 mm

Depth

58 mm

58 mm

Article number

6AG1055-1MA00-7BA2

SIPLUS LOGO! AM2 V8

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 12 V DC

Yes; 10.8 V DC to 28.8 V DC

  • ● 24 V DC

Yes; 10.8 V DC to 28.8 V DC

Analog inputs

Number of analog inputs

2

Input ranges

  • ● Voltage

Yes

  • ● Current

Yes

  • ● Resistance thermometer

No

Input ranges (rated values), voltages

  • ● 0 to +10 V

Yes

Input ranges (rated values), currents

  • ● 0 to 20 mA

Yes; 0 mA or 4 mA to 20 mA

Input ranges (rated values), resistance thermometer

  • ● Pt 100

No

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Standards, approvals, certificates

CE mark

Yes

CSA approval

No

UL approval

No

FM approval

No

developed in accordance with IEC 61131

Yes

according to VDE 0631

Yes

Marine approval

Yes

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin; Startup @ -25 °C

  • ● max.

70 °C; = Tmax

  • ● At cold restart, min.

-25 °C

Ambient temperature during storage/transportation

  • ● min.

-40 °C

  • ● max.

70 °C

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Dimensions

Width

35.5 mm

Height

90 mm

Depth

58 mm

Article number

6AG1055-1MM00-7BA2

SIPLUS LOGO! AM2 AQ V8

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 12 V DC

No

  • ● 24 V DC

Yes

Analog outputs

Number of analog outputs

2

Output ranges, voltage

  • ● 0 to 10 V

Yes

Output ranges, current

  • ● 0 to 20 mA

Yes

  • ● 4 mA to 20 mA

Yes

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Standards, approvals, certificates

CE mark

Yes

developed in accordance with IEC 61131

Yes

according to VDE 0631

Yes

Marine approval

Yes

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin; Startup @ -25 °C

  • ● max.

70 °C; = Tmax

  • ● At cold restart, min.

-25 °C

Ambient temperature during storage/transportation

  • ● min.

-40 °C

  • ● max.

70 °C

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Dimensions

Width

35.5 mm

Height

90 mm

Depth

58 mm

Article number

6AG1055-1CB00-2BY0

6AG1055-1PB00-2BY0

6AG1055-1HB00-2BY0

6AG1055-1MB00-2BY1

SIPLUS LOGO! DM8 24

SIPLUS LOGO! DM8 12/24

SIPLUS LOGO! DM8 24R

SIPLUS LOGO! DM8 12/24R

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 12 V DC

Yes

  • ● 24 V DC

Yes

Yes

Yes

Yes

permissible range, lower limit (DC)

20.4 V; 22 V @ >55 °C

10.8 V; 11 V @ >55 °C

20.4 V; 22 V @ >55 °C

10.8 V; 11 V @ >55 °C

permissible range, upper limit (DC)

28.8 V; 27.5 V @ >55 °C

28.8 V; 27.5 V @ >55 °C

28.8 V; 27.5 V @ >55 °C

28.8 V; 27.5 V @ >55 °C

Rated value (AC)

  • ● 24 V AC

Yes

Digital inputs

Number of digital inputs

4

4

4

4

Input voltage

  • ● Type of input voltage

DC

DC

AC/DC

DC

Digital outputs

Number of digital outputs

4; Transistor

4; Transistor

4; Relays

4; Relays

Short-circuit protection

Yes

Yes

No

No

Output current

  • ● for signal “1” rated value

0.3 A; 0.2 A @ > 55 °C; 0.3 A @ > 55 °C & < 15 s

0.3 A; 0.2 A @ > 55 °C; 0.3 A @ > 55 °C & < 15 s

5 A

5 A

Relay outputs

Switching capacity of contacts

  • — with inductive load, max.

3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s

3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s

  • — with resistive load, max.

5 A; 3 A per relay @ > 55 °C; 5 A < 15 s; 10 A all 4 relays in total

5 A; 3 A per relay @ > 55 °C; 5 A < 15 s; 10 A all 4 relays in total

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Yes

Yes

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Yes

Yes

Yes

Standards, approvals, certificates

CSA approval

No

No

No

No

UL approval

Yes; File: E120869 // Tmax = 55 °C

Yes; File: E120869 // Tmax = 55 °C

Yes; File: E120869 // Tmax = 55 °C

Yes; File: E120869 // Tmax = 55 °C

FM approval

No

No

No

No

developed in accordance with IEC 61131

Yes

Yes

Yes

Yes

according to VDE 0631

Yes

Yes

Yes

Yes

Marine approval

No

No

No

No

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin

-40 °C; = Tmin

-40 °C; = Tmin

-40 °C; = Tmin

  • ● max.

70 °C; = Tmax; 55 °C @ UL/cUL use

70 °C; = Tmax; 55 °C @ UL/cUL use

70 °C; = Tmax; 55 °C @ UL/cUL use

70 °C; = Tmax; 55 °C @ UL/cUL use

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

Dimensions

Width

36 mm; 2 DU

36 mm; 2 DU

36 mm; 2 DU

36 mm; 2 DU

Height

90 mm

90 mm

90 mm

90 mm

Depth

55 mm

55 mm

55 mm

55 mm

Article number

6AG1055-1FB00-2BY1

6AG1055-1NB10-2BA0

SIPLUS LOGO! DM8 230R

SIPLUS LOGO! DM16 24R ERW.-MODUL

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

on 35 mm DIN rail, 4 spacing units wide

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes

  • ● 115 V DC

Yes

  • ● 230 V DC

Yes

permissible range, lower limit (DC)

100 V

20.4 V; 22 V @ >55 °C

permissible range, upper limit (DC)

253 V

28.8 V; 27.5 V @ >55 °C

Rated value (AC)

  • ● 115 V AC

Yes

  • ● 230 V AC

Yes

Digital inputs

Number of digital inputs

4

8

Input voltage

  • ● Type of input voltage

AC/DC

DC

  • ● for signal “0”

< 5 V DC

  • ● for signal “1”

> 12 V DC

Input current

  • ● for signal “0”, max. (permissible quiescent current)

1 mA

  • ● for signal “1”, typ.

2 mA

Input delay (for rated value of input voltage)

for standard inputs

  • — at “0” to “1”, max.

1.5 ms

  • — at “1” to “0”, max.

1.5 ms

Digital outputs

Number of digital outputs

4; Relays

8; Relays

Short-circuit protection

No

No

Controlling a digital input

Yes

Switching capacity of the outputs

  • ● on lamp load, max.

1 000 W; 500 W at 115V AC

Output current

  • ● for signal “1” rated value

5 A

5 A

Parallel switching of two outputs

  • ● for uprating

No

Switching frequency

  • ● with resistive load, max.

2 Hz

  • ● with inductive load, max.

0.5 Hz

  • ● mechanical, max.

10 Hz

Relay outputs

Switching capacity of contacts

  • — with inductive load, max.

3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s

3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s

  • — with resistive load, max.

5 A; 3 A per relay @ > 55 °C; 5 A < 15 s; 10 A all 4 relays in total

5 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Yes

Standards, approvals, certificates

CSA approval

No

No

UL approval

Yes; File: E120869 // Tmax = 55 °C

In application process

FM approval

No

No

developed in accordance with IEC 61131

Yes

Yes

according to VDE 0631

Yes

Yes

Marine approval

No

No

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin

-25 °C; = Tmin

  • ● max.

70 °C; = Tmax; 55 °C @ UL/cUL use

70 °C; = Tmax; 55 °C @ UL/cUL use

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m)

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

Dimensions

Width

36 mm; 2 DU

72 mm; 4 WU

Height

90 mm

90 mm

Depth

55 mm

53 mm

Article number

6AG1055-1MA00-2BY0

SIPLUS LOGO! AM2

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 12 V DC

Yes

  • ● 24 V DC

Yes

Analog inputs

Number of analog inputs

2

Input ranges

  • ● Voltage

Yes

  • ● Current

Yes

  • ● Resistance thermometer

No

Input ranges (rated values), voltages

  • ● 0 to +10 V

Yes

Input ranges (rated values), currents

  • ● 0 to 20 mA

Yes

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Standards, approvals, certificates

CSA approval

No

UL approval

Yes; File: E120869 // Tmax = 55 °C

FM approval

No

developed in accordance with IEC 61131

Yes

according to VDE 0631

Yes

Marine approval

No

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin

  • ● max.

70 °C; = Tmax; 55 °C @ UL/cUL use

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

Dimensions

Width

36 mm

Height

90 mm

Depth

55 mm

Article number

6AG1055-1MM00-2BY1

SIPLUS_LOGO!_AM2_AQ

Installation type/mounting

Mounting

on 35 mm DIN rail, 2 spacing units wide

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes

Analog outputs

Number of analog outputs

2

Output ranges, voltage

  • ● 0 to 10 V

Yes

Output ranges, current

  • ● 0 to 20 mA

Yes

  • ● 4 mA to 20 mA

Yes

EMC

Emission of radio interference acc. to EN 55 011

  • ● Limit class B, for use in residential areas

Yes; Radio interference suppression according to EN55011, Limit Value Class B

Degree and class of protection

Degree of protection acc. to EN 60529

  • ● IP20

Yes

Standards, approvals, certificates

CSA approval

No

UL approval

No

FM approval

No

developed in accordance with IEC 61131

Yes

according to VDE 0631

Yes

Marine approval

No

Ambient conditions

Ambient temperature during operation

  • ● min.

-40 °C; = Tmin

  • ● max.

70 °C; = Tmax; 55 °C @ UL/cUL use

Altitude during operation based on sea level

  • ● Ambient air temperature-barometric pressure-altitude

Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m)

Relative humidity

  • ● With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)

Dimensions

Width

36 mm

Height

90 mm

Depth

55 mm