Ambient temperature range

-10 … +50 °C

Conformal Coating

Coating of the printed circuit board and the electronic components

Technical specifications

The technical specifications of the standard product apply with the exception of the ambient conditions.

Ambient conditions

Relative atmospheric humidity

5 … 100%,
condensation permissible

Application

The SIPLUS MICROMASTER 440 inverter can be used for a variety of variable-speed drive tasks. Its flexibility makes it suitable for a wide range of applications. This wide range includes cranes and hoisting gear, high-bay warehouses, machines for the food and beverages industry, packaging machines, etc.; i.e. applications that require frequency inverters with higher functionality and higher dynamic response than normal.

The inverter is especially characterized by its customer-oriented performance and ease-of-use. Its large range of line voltages enables it to be used all over the world.

Design

The SIPLUS MICROMASTER 440 inverter has a modular design. The operator panels and modules can be easily exchanged.

Main features

  • Easy, guided commissioning
  • Modular construction allows maximum configuration flexibility
  • 6 programmable isolated digital inputs
  • 2 analog inputs (0 V to 10 V, 0 mA to 20 mA, scalable) can also be used as a 7th/8th digital input
  • 2 programmable analog outputs (0 mA to 20 mA)
  • 3 programmable relay outputs (30 V DC/5 A, resistive load; 250 V AC/2 A, inductive load
  • Low-noise motor operation through high pulse frequencies, adjustable (observe derating if necessary)
  • Protection for motor and inverter

Accessories (overview)

  • EMC filter, class A/B
  • LC filter and sine-wave filter
  • Line commutating reactors
  • Output reactors
  • Shield connection plates
  • Basic Operator Panel (BOP) for parameterizing the inverter
  • Plain-text Advanced Operator Panel (AOP) with multiple-language display
  • Plain-text Asian Advanced Operator Panel (AAOP) with Chinese and English display
  • Plain-text Cyrillic Advanced Operator Panel (CAOP) with Cyrillic, German and English display
  • Communication modules
    • PROFIBUS
    • DeviceNet
    • CANopen
  • Incremental encoder evaluation module
  • PC connection kits
  • Mounting kits for installing the operator panels in control cabinet doors
  • PC commissioning programs under Windows 98/NT/2000/XP Professional
  • TIA integration with Drive ES

Technical specifications

Technical data

MICROMASTER 440

Mains voltage and power ranges

CT (constant torque)

VT (variable torque)

200 V to 240 V 1 AC  ±10 %

0.12 kW to 3 kW

200 V to 240 V 3 AC  ±10 %

0.12 kW to 45 kW

5.5 kW to 55 kW

380 V to 480 V 3 AC  ±10 %

0.37 kW to 200 kW

7.5 kW to 250 kW

500 V to 600 V 3 AC  ±10 %

0.75 kW to 75 kW

1.5 kW to 90 kW

Input frequency

47 Hz to 63 Hz

Output frequency

in V/f mode

for inverter 0.12 kW to 75 kW

0 … 650 Hz, (limitation to 550 Hz in production to comply with legal requirements) 1)

for inverter 90 kW to 200 kW

0 Hz to 267 Hz

in vector mode

for inverter 0.12 kW to 75 kW

0 Hz to 200 Hz

for inverter 90 kW to 200 kW

0 Hz to 200 Hz

Power factor

≥ 0.95

Inverter efficiency

0.12 kW to 75 kW: 96 % to 97 %; 90 kW to 200 kW: 97 % to 98 %

Overload capability

CT mode

for inverter 0.12 kW to 75 kW

Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s, and 2 x rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s

for inverter 90 kW to 200 kW

Overload current 1.36 x rated output current (i.e. 136 % overload capability) for 57 s, cycle time 300 s, and 1.6 x rated output current (i.e. 160 % overload capability) for 3 s, cycle time 300 s

Overload capability

VT mode

for inverter 5.5 kW to 90 kW

Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s, and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s

for inverter 110 kW to 250 kW

Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s, and 1.1 x rated output current (i.e. 110 % overload capability) for 59 s, cycle time 300 s

Inrush current

not higher than rated input current

Control method

Vector control, torque control, linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic (programmable V/f characteristic); flux current control (FCC)

Pulse frequency

for inverter 0.12 kW to 75 kW

4 kHz (standard); 16 kHz (standard with 230 V inverters 0.12 kW to 5.5 kW)
2 kHz to 16 kHz (in 2 kHz steps)

for inverter 90 kW to 200 kW

2 kHz (standard with VT mode); 4 kHz (standard with CT mode)