SIEMENS SIPLUS S7-300 CPU 315-2 PN/DP Technical specifications
SIPLUS S7-300 CPU 315-2 PN/DP
SIMATIC Micro Memory Card required for operation of CPU.
- The CPU with medium-sized program memory and quantity frameworks
- High processing performance in binary and floating-point arithmetic
- Used as central controller in production lines with central and distributed I/O
- Component Based Automation (CBA) on PROFINET
- PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA)
- PROFINET IO Controller for operating distributed I/O on PROFINET
- PROFINET interface with 2-port switch
- Combined MPI/PROFIBUS DP master/slave interface
- Isochronous mode on PROFIBUS
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.
SIPLUS S7-300 CPU 315-2 PN/DP Ordering data
Product No. / Product Description | Listprice / Your price | ||||||
![]() | 6AG1315-2EH14-2AY0 SIPLUS S7-300 CPU315-2PN/DP -25 … +60 DEGREES C WITH CONFORMITY TO EN50155 T1 CAT 1 CL A/B BASED ON 6ES7315-2EH14-0AB0 . CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY | ||||||
![]() | 6AG1315-2EH14-7AB0 SIPLUS S7-300 CPU315-2PN/DP -25 … +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7315-2EH14-0AB0 . CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY |
The CPU 315-2 PN/DP is a CPU with medium-sized program memory. It is used in plants containing distributed automation structures in addition to a centralized I/O. It can be implemented as a PROFINET IO controller and as a standard PROFIBUS DP master in the SIMATIC S7-300. The 315-2 PN/DP CPU can also be used as distributed intelligence (PROFIBUS DP slave or PROFINET I-Device).
The CPU 315-2 PN/DP is an ideal platform for simple software-implemented technological tasks, e.g.:
- Motion control with Easy Motion Control.
- Implementation of control engineering tasks using STEP 7 blocks or runtime software Standard PID Control/Modular PID Control.
An extended process diagnosis is possible by using SIMATIC S7-PDIAG.
The integrated communication options of the CPU enable networked automation solutions to be implemented without additional components.
Technical specifications
Article number | 6AG1315-2EH14-2AY0 | 6AG1315-2EH14-7AB0 | |
---|---|---|---|
SIPLUS S7-300 CPU315-2PN/DP EN50155 | SIPLUS S7-300 CPU315-2PN/DP | ||
General information | |||
Hardware product version | 01 | 01 | |
Firmware version | V3.2 | V3.2 | |
Engineering with | |||
| STEP 7 V5.5 or higher | STEP 7 V5.5 or higher | |
Supply voltage | |||
Rated value (DC) | |||
| Yes; A power supply according to EN 50155 shall be used | Yes | |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | |
external protection for power supply lines (recommendation) | 2 A min. | 2 A min. | |
Mains buffering | |||
| 5 ms | 5 ms | |
| 1 s | 1 s | |
Input current | |||
Current consumption (rated value) | 750 mA | 750 mA | |
Current consumption (in no-load operation), typ. | 150 mA | 150 mA | |
Inrush current, typ. | 4 A | 4 A | |
I²t | 1 A²·s | 1 A²·s | |
Power loss | |||
Power loss, typ. | 4.65 W | 4.65 W | |
Memory | |||
Work memory | |||
| 384 kbyte | 384 kbyte | |
| No | No | |
| 128 kbyte | 128 kbyte | |
Load memory | |||
| Yes | Yes | |
| 8 Mbyte | 8 Mbyte | |
| 10 y | 10 y | |
Backup | |||
| Yes; Guaranteed by MMC (maintenance-free) | Yes; Guaranteed by MMC (maintenance-free) | |
| Yes; Program and data | Yes; Program and data | |
CPU processing times | |||
for bit operations, typ. | 0.05 µs | 0.05 µs | |
for word operations, typ. | 0.09 µs | 0.09 µs | |
for fixed point arithmetic, typ. | 0.12 µs | 0.12 µs | |
for floating point arithmetic, typ. | 0.45 µs | 0.45 µs | |
CPU-blocks | |||
Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
DB | |||
| 1 024; Number range: 1 to 16000 | 1 024; Number range: 1 to 16000 | |
| 64 kbyte | 64 kbyte | |
FB | |||
| 1 024; Number range: 0 to 7999 | 1 024; Number range: 0 to 7999 | |
| 64 kbyte | 64 kbyte | |
FC | |||
| 1 024; Number range: 0 to 7999 | 1 024; Number range: 0 to 7999 | |
| 64 kbyte | 64 kbyte | |
OB | |||
| 64 kbyte | 64 kbyte | |
| 1; OB 1 | 1; OB 1 | |
| 1; OB 10 | 1; OB 10 | |
| 2; OB 20, 21 | 2; OB 20, 21 | |
| 4; OB 32, 33, 34, 35 | 4; OB 32, 33, 34, 35 | |
| 1; OB 40 | 1; OB 40 | |
| 3; OB 55, 56, 57 | 3; OB 55, 56, 57 | |
| 1; OB 61 | 1; OB 61 | |
| 1; OB 100 | 1; OB 100 | |
| 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) | |
| 2; OB 121, 122 | 2; OB 121, 122 | |
Nesting depth | |||
| 16 | 16 | |
| 4 | 4 | |
Counters, timers and their retentivity | |||
S7 counter | |||
| 256 | 256 | |
Retentivity | |||
| Yes | Yes | |
| 0 | 0 | |
| 255 | 255 | |
| Z 0 to Z 7 | Z 0 to Z 7 | |
Counting range | |||
| Yes | Yes | |
| 0 | 0 | |
| 999 | 999 | |
IEC counter | |||
| Unlimited (limited only by RAM capacity) | Unlimited (limited only by RAM capacity) | |
S7 times | |||
| 256 | 256 | |
Retentivity | |||
| Yes | Yes | |
| 0 | 0 | |
| 255 | 255 | |
| No retentivity | No retentivity | |
Time range | |||
| 10 ms | 10 ms | |
| 9 990 s | 9 990 s | |
IEC timer | |||
| Yes | Yes | |
| SFB | SFB | |
| Unlimited (limited only by RAM capacity) | Unlimited (limited only by RAM capacity) | |
Data areas and their retentivity | |||
retentive data area in total | All, 128 KB max. | All, 128 KB max. | |
Flag | |||
| 2 048 byte | 2 048 byte | |
| Yes; MB 0 to MB 2047 | Yes; MB 0 to MB 2047 | |
| MB 0 to MB 15 | MB 0 to MB 15 | |
| 8; 1 memory byte | 8; 1 memory byte | |
Data blocks | |||
| 1 024; Number range: 1 to 16000 | 1 024; Number range: 1 to 16000 | |
| 64 kbyte | 64 kbyte | |
| Yes; via non-retain property on DB | Yes; via non-retain property on DB | |
| Yes | Yes | |
Local data | |||
| 32 768 byte; Max. 2048 bytes per block | 32 768 byte; Max. 2048 bytes per block | |
Address area | |||
I/O address area | |||
| 2 048 byte | 2 048 byte | |
| 2 048 byte | 2 048 byte | |
of which distributed | |||
| 2 048 byte | 2 048 byte | |
| 2 048 byte | 2 048 byte | |
Process image | |||
| 2 048 byte | 2 048 byte | |
| 2 048 byte | 2 048 byte | |
| 2 048 byte | 2 048 byte | |
| 2 048 byte | 2 048 byte | |
| 128 byte | 128 byte | |
| 128 byte | 128 byte | |
Subprocess images | |||
| 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | |
Digital channels | |||
| 16 384 | 16 384 | |
| 1 024 | 1 024 | |
| 16 384 | 16 384 | |
| 1 024 | 1 024 | |
Analog channels | |||
| 1 024 | 1 024 | |
| 256 | 256 | |
| 1 024 | 1 024 | |
| 256 | 256 | |
Hardware configuration | |||
Number of expansion units, max. | 3 | 3 | |
Number of DP masters | |||
| 1 | 1 | |
| 4 | 4 | |
Number of operable FMs and CPs (recommended) | |||
| 8 | 8 | |
| 8 | 8 | |
| 10 | 10 | |
Rack | |||
| 4 | 4 | |
| 8 | 8 | |
Time of day | |||
Clock | |||
| Yes | Yes | |
| Yes | Yes | |
| 6 wk; At 40 °C ambient temperature | 6 wk; At 40 °C ambient temperature | |
| 10 s; Typ.: 2 s | 10 s; Typ.: 2 s | |
| Clock continues running after POWER OFF | Clock continues running after POWER OFF | |
| Clock continues to run with the time at which the power failure occurred | Clock continues to run with the time at which the power failure occurred | |
Operating hours counter | |||
| 1 | 1 | |
| 0 | 0 | |
| 0 to 2^31 hours (when using SFC 101) | 0 to 2^31 hours (when using SFC 101) | |
| 1 hour | 1 hour | |
| Yes; Must be restarted at each restart | Yes; Must be restarted at each restart | |
Clock synchronization | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes; With DP slave only slave clock | Yes; With DP slave only slave clock | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes; As client | Yes; As client | |
Digital inputs | |||
Number of digital inputs | 0 | 0 | |
Digital outputs | |||
Number of digital outputs | 0 | 0 | |
Analog inputs | |||
Number of analog inputs | 0 | 0 | |
Analog outputs | |||
Number of analog outputs | 0 | 0 | |
Interfaces | |||
Number of industrial Ethernet interfaces | 1; 2 ports (switch) RJ45 | 1; 2 ports (switch) RJ45 | |
Number of RS 485 interfaces | 1; Combined MPI / PROFIBUS DP | 1; Combined MPI / PROFIBUS DP | |
Number of RS 422 interfaces | 0 | 0 | |
1. Interface | |||
Interface type | Integrated RS 485 interface | Integrated RS 485 interface | |
Physics | RS 485 | RS 485 | |
Isolated | Yes | Yes | |
Power supply to interface (15 to 30 V DC), max. | 200 mA | 200 mA | |
Functionality | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| No | No | |
MPI | |||
| 12 Mbit/s | 12 Mbit/s | |
Services | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| No; but via CP and loadable FB | No; but via CP and loadable FB | |
| Yes | Yes | |
DP master | |||
| 12 Mbit/s | 12 Mbit/s | |
| 124 | 124 | |
Services | |||
| Yes | Yes | |
| Yes | Yes | |
| No | No | |
| Yes; I blocks only | Yes; I blocks only | |
| Yes | Yes | |
| No | No | |
| Yes | Yes | |
| Yes | Yes | |
| Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | |
| Yes | Yes | |
| Yes | Yes | |
| 8 | 8 | |
| Yes; As subscriber | Yes; As subscriber | |
| Yes | Yes | |
Address area | |||
| 2 kbyte | 2 kbyte | |
| 2 kbyte | 2 kbyte | |
User data per DP slave | |||
| 244 byte | 244 byte | |
| 244 byte | 244 byte | |
DP slave | |||
| 12 Mbit/s | 12 Mbit/s | |
| Yes; only with passive interface | Yes; only with passive interface | |
| 32 | 32 | |
| 32 byte | 32 byte | |
Services | |||
| Yes | Yes | |
| Yes; Only with active interface | Yes; Only with active interface | |
| No | No | |
| No | No | |
| Yes | Yes | |
| No | No | |
| Yes; Connection configured on one side only | Yes; Connection configured on one side only | |
| Yes | Yes | |
| No | No | |
Transfer memory | |||
| 244 byte | 244 byte | |
| 244 byte | 244 byte | |
2. Interface | |||
Interface type | PROFINET | PROFINET | |
Physics | Ethernet RJ45 | Ethernet RJ45 | |
Isolated | Yes | Yes | |
automatic detection of transmission rate | Yes; 10/100 Mbit/s | Yes; 10/100 Mbit/s | |
Autonegotiation | Yes | Yes | |
Autocrossing | Yes | Yes | |
Change of IP address at runtime, supported | Yes | Yes | |
Interface types | |||
| 2 | 2 | |
| Yes | Yes | |
Media redundancy | |||
| Yes | Yes | |
| 200 ms; PROFINET MRP | 200 ms; PROFINET MRP | |
| 50 | 50 | |
Functionality | |||
| No | No | |
| Yes; Also simultaneously with IO-Device functionality | Yes; Also simultaneously with IO-Device functionality | |
| Yes; Also simultaneously with IO Controller functionality | Yes; Also simultaneously with IO Controller functionality | |
| Yes | Yes | |
| No | No | |
| No | No | |
| Yes; Via TCP/IP, ISO on TCP, and UDP | Yes; Via TCP/IP, ISO on TCP, and UDP | |
| Yes | Yes | |
| 5 | 5 | |
PROFINET IO Controller | |||
| 100 Mbit/s | 100 Mbit/s | |
Services | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 | Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 | |
| Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | |
| Yes; Via TCP/IP, ISO on TCP, and UDP | Yes; Via TCP/IP, ISO on TCP, and UDP | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| 32 | 32 | |
| 128 | 128 | |
| 64 | 64 | |
| 64 | 64 | |
| 128 | 128 | |
| 61 | 61 | |
| 128 | 128 | |
| 128 | 128 | |
| Yes | Yes | |
| 8 | 8 | |
| Yes | Yes | |
| 8 | 8 | |
| Yes | Yes | |
| 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with “high flexibility” option) | 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with “high flexibility” option) | |
| 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, Technical Data” for more details) | 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, Technical Data” for more details) | |
Address area | |||
| 2 kbyte | 2 kbyte | |
| 2 kbyte | 2 kbyte | |
| 1 024 byte | 1 024 byte | |
PROFINET IO Device | |||
Services | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 | Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 | |
| No | No | |
| Yes; Via TCP/IP, ISO on TCP, and UDP | Yes; Via TCP/IP, ISO on TCP, and UDP | |
| Yes | Yes | |
| Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device | |
| Yes | Yes | |
| 2 | 2 | |
Transfer memory | |||
| 1 440 byte; Per IO Controller with shared device | 1 440 byte; Per IO Controller with shared device | |
| 1 440 byte; Per IO Controller with shared device | 1 440 byte; Per IO Controller with shared device | |
Submodules | |||
| 64 | 64 | |
| 1 024 byte | 1 024 byte | |
PROFINET CBA | |||
| Yes | Yes | |
| Yes | Yes | |
Open IE communication | |||
| 8 | 8 | |
| 0, 20, 21, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | 0, 20, 21, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | |
| Yes | Yes | |
Protocols | |||
Open IE communication | |||
| |||
| 8 | 8 | |
| 1 460 byte | 1 460 byte | |
| 32 768 byte | 32 768 byte | |
| Yes | Yes | |
| Yes; via integrated PROFINET interface and loadable FBs | Yes; via integrated PROFINET interface and loadable FBs | |
| 8 | 8 | |
| 32 768 byte | 32 768 byte | |
| |||
| 8 | 8 | |
| 1 472 byte | 1 472 byte | |
Isochronous mode | |||
Isochronous operation (application synchronized up to terminal) | Yes; Via PROFIBUS DP or PROFINET interface | Yes; Via PROFIBUS DP or PROFINET interface | |
Communication functions | |||
PG/OP communication | Yes | Yes | |
Data record routing | Yes | Yes | |
Global data communication | |||
| Yes | Yes | |
| 8 | 8 | |
| 8 | 8 | |
| 8 | 8 | |
| 8 | 8 | |
| 22 byte | 22 byte | |
| 22 byte | 22 byte | |
S7 basic communication | |||
| Yes | Yes | |
| 76 byte | 76 byte | |
| 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | |
S7 communication | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB | Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB | |
| See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
S5 compatible communication | |||
| Yes; via CP and loadable FC | Yes; via CP and loadable FC | |
Open IE communication | |||
| Yes; via integrated PROFINET interface and loadable FBs | Yes; via integrated PROFINET interface and loadable FBs | |
| Yes; via integrated PROFINET interface and loadable FBs | Yes; via integrated PROFINET interface and loadable FBs | |
Web server | |||
| Yes | Yes | |
| 5 | 5 | |
| Yes | Yes | |
PROFINET CBA (at set setpoint communication load) | |||
| 50 % | 50 % | |
| 32 | 32 | |
| 30 | 30 | |
| 1 000 | 1 000 | |
| 4 000 byte | 4 000 byte | |
| 4 000 byte | 4 000 byte | |
| 500 | 500 | |
| 4 000 byte | 4 000 byte | |
| 1 400 byte | 1 400 byte | |
Remote interconnections with acyclic transmission | |||
| 500 ms | 500 ms | |
| 100 | 100 | |
| 100 | 100 | |
| 2 000 byte | 2 000 byte | |
| 2 000 byte | 2 000 byte | |
| 1 400 byte | 1 400 byte | |
Remote interconnections with cyclic transmission | |||
| 10 ms | 10 ms | |
| 200 | 200 | |
| 200 | 200 | |
| 2 000 byte | 2 000 byte | |
| 2 000 byte | 2 000 byte | |
| 450 byte | 450 byte | |
HMI variables via PROFINET (acyclic) | |||
| 3; 2x PN OPC/1x iMap | 3; 2x PN OPC/1x iMap | |
| 500 ms | 500 ms | |
| 200 | 200 | |
| 2 000 byte | 2 000 byte | |
PROFIBUS proxy functionality | |||
| Yes | Yes | |
| 16 | 16 | |
| 240 byte; Slave-dependent | 240 byte; Slave-dependent | |
Number of connections | |||
| 16 | 16 | |
| 15 | 15 | |
| 1 | 1 | |
| 1 | 1 | |
| 15 | 15 | |
| 15 | 15 | |
| 1 | 1 | |
| 1 | 1 | |
| 15 | 15 | |
| 14 | 14 | |
| 0 | 0 | |
| 0 | 0 | |
| 14 | 14 | |
| 14 | 14 | |
| 0 | 0 | |
| 0 | 0 | |
| 14 | 14 | |
| 32 | 32 | |
| X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. | X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. | |
S7 message functions | |||
Number of login stations for message functions, max. | 16; Depending on the configured connections for PG/OP and S7 basic communication | 16; Depending on the configured connections for PG/OP and S7 basic communication | |
Process diagnostic messages | Yes | Yes | |
simultaneously active Alarm-S blocks, max. | 300 | 300 | |
Test commissioning functions | |||
Status block | Yes; Up to 2 simultaneously | Yes; Up to 2 simultaneously | |
Single step | Yes | Yes | |
Number of breakpoints | 4 | 4 | |
Status/control | |||
| Yes | Yes | |
| Inputs, outputs, memory bits, DB, times, counters | Inputs, outputs, memory bits, DB, times, counters | |
| 30 | 30 | |
| 30 | 30 | |
| 14 | 14 | |
Forcing | |||
| Yes | Yes | |
| Inputs, outputs | Inputs, outputs | |
| 10 | 10 | |
Diagnostic buffer | |||
| Yes | Yes | |
| 500 | 500 | |
| No | No | |
| 100; Only the last 100 entries are retained | 100; Only the last 100 entries are retained | |
| 499 | 499 | |
| Yes; From 10 to 499 | Yes; From 10 to 499 | |
| 10 | 10 | |
Service data | |||
| Yes | Yes | |
Standards, approvals, certificates | |||
CE mark | Yes | Yes | |
UL approval | Yes; File E239877 | Yes; File E239877 | |
FM approval | Yes; CofC 3028431 | Yes; CofC 3028431 | |
RCM (formerly C-TICK) | Yes | Yes | |
KC approval | Yes | Yes | |
EAC (formerly Gost-R) | Yes | Yes | |
Railway application | |||
| Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B | ||
Use in hazardous areas | |||
| Yes | Yes | |
Ambient conditions | |||
Ambient temperature during operation | |||
| -25 °C; = Tmin | -25 °C; = Tmin | |
| 60 °C; = Tmax; the rated temperature range of -25 … +55 °C (T1) applies for the use on railway vehicles according to EN50155 | 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use | |
Ambient temperature during storage/transportation | |||
| -40 °C | -40 °C | |
| 70 °C | 70 °C | |
Altitude during operation based on sea level | |||
| Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | |
Relative humidity | |||
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Configuration | |||
Configuration software | |||
| Yes; V5.5 or higher | Yes; V5.5 or higher | |
Programming | |||
| see instruction list | see instruction list | |
| 8 | 8 | |
| see instruction list | see instruction list | |
| see instruction list | see instruction list | |
Programming language | |||
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | Yes | |
Know-how protection | |||
| Yes | Yes | |
| Yes; With S7 block Privacy | Yes; With S7 block Privacy | |
Dimensions | |||
Width | 40 mm | 40 mm | |
Height | 125 mm | 125 mm | |
Depth | 130 mm | 130 mm | |
Weights | |||
Weight, approx. | 340 g | 340 g |