SIEMENS SIPLUS S7-300 SM 332 Product Information
Overview
- Analog outputs
- For connection of analog actuators
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.
Application
Analog output modules can be used to output analog signals from the PLC to the process. They are suitable for connecting analog actuators.
Function
The analog output modules convert numerical values from the controller into analog signals (current or voltage) for the process.
The modules feature:
- Resolution: 12 to 15 bit
- Different voltage and current ranges:
the ranges are set independently for each channel by means of the parameterization software. - Interrupt capability:
in the event of errors, the module sends diagnostic interrupts to the CPU of the controller. - Diagnostics:
the module sends extensive diagnostic information to the CPU.
Technical specifications
Article number | 6AG1332-5HD01-7AB0 | 6AG1332-7ND02-4AB0 | 6AG1332-5HB01-2AB0 | 6AG1332-5HF00-2AB0 | |
---|---|---|---|---|---|
SIPLUS S7-300 SM332 4AA U/I | SIPLUS S7-300 SM332 4AA | SIPLUS S7-300 SM332 2AO | SIPLUS S7-300 SM 332 8AO – 40pol | ||
Supply voltage | |||||
Load voltage L+ | |||||
| 24 V | 24 V | 24 V; A power supply according to EN 50155 shall be used for railway applications | 24 V | |
| Yes | Yes | Yes | Yes | |
Input current | |||||
from load voltage L+ (without load), max. | 240 mA | 290 mA | 135 mA | 340 mA | |
from backplane bus 5 V DC, max. | 60 mA | 120 mA | 60 mA | 100 mA | |
Power loss | |||||
Power loss, typ. | 3 W | 3 W | 3 W | 6 W | |
Analog outputs | |||||
Number of analog outputs | 4 | 4; Isochronous mode | 2 | 8; 4 @ +70 °C | |
Voltage output, short-circuit protection | Yes | Yes | Yes | Yes | |
Voltage output, short-circuit current, max. | 25 mA | 40 mA | 25 mA | 25 mA | |
Current output, no-load voltage, max. | 18 V | 18 V | 18 V | 18 V | |
Output ranges, voltage | |||||
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Output ranges, current | |||||
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Load impedance (in rated range of output) | |||||
| 1 kΩ | 1 kΩ | 1 kΩ | 1 kΩ | |
| 1 µF | 1 µF | 1 µF | 1 µF | |
| 500 Ω | 500 Ω | 500 Ω | 500 Ω | |
| 10 mH | 1 mH | 10 mH | 10 mH | |
Cable length | |||||
| 200 m | 200 m | 200 m | 200 m | |
Analog value generation for the outputs | |||||
Integration and conversion time/resolution per channel | |||||
| 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit | 16 bit | 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit | 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit | |
| 0.8 ms | 200 µs; in isochronous mode 640 µs | 0.8 ms | 0.8 ms | |
Settling time | |||||
| 0.2 ms | 0.2 ms | 0.2 ms | 0.2 ms | |
| 3.3 ms | 3.3 ms | 3.3 ms | 3.3 ms | |
| 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH) | 0.5 ms | 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH) | 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH) | |
Errors/accuracies | |||||
Operational error limit in overall temperature range | |||||
| 0.5 %; ±0.6 % @ < 0 °C or > 60 °C | 0.12 % | 0.5 %; ±0.6 % @ < 0 °C or > 60 °C | 0.5 %; ±0.6 % @ < 0 °C or > 60 °C | |
| 0.6 %; ±0.7 % @ < 0 °C or > 60 °C | 0.18 % | 0.6 %; /-0.7% @ < 0 °C or > 60 °C | 0.6 %; ±0.7 % @ < 0 °C or > 60 °C | |
Basic error limit (operational limit at 25 °C) | |||||
| 0.4 % | 0.02 % | 0.4 % | 0.4 % | |
| 0.5 % | 0.02 % | 0.5 % | 0.5 % | |
Interrupts/diagnostics/status information | |||||
Diagnostic functions | Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable | ||
Substitute values connectable | Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable | |
Alarms | |||||
| Yes; Parameterizable | Yes | Yes; Parameterizable | Yes; Parameterizable | |
Diagnostic messages | |||||
| Yes | Yes | Yes | ||
Diagnostics indication LED | |||||
| Yes | Yes | Yes | Yes | |
Potential separation | |||||
Potential separation analog outputs | |||||
| Yes | Yes | Yes | Yes | |
Isolation | |||||
Isolation tested with | 500 V DC | 1500 V DC | 500 V DC | 500 V DC | |
Standards, approvals, certificates | |||||
CE mark | Yes | Yes | Yes | Yes | |
UL approval | Yes; File E239877 | Yes; File E239877 | Yes; File E239877 | Yes; File E239877 | |
FM approval | Yes; CofC 3028431 | Yes | Yes; CofC 3028431 | Yes; CofC 3028431 | |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes | |
KC approval | Yes | Yes | Yes | Yes | |
EAC (formerly Gost-R) | Yes | Yes | Yes | Yes | |
Railway application | |||||
| No | No | No | ||
| No | Yes; T1 Category 1 Class A/B horizontal mounting position | No | ||
Ambient conditions | |||||
Ambient temperature during operation | |||||
| -25 °C; = Tmin | 0 °C; = Tmin | -25 °C; = Tmin | -25 °C | |
| 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use | 60 °C; = Tmax | 70 °C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 … +55 °C (T1) or 60 °C @ UL/ULhaz/ATEX/FM use applies | 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use | |
Ambient temperature during storage/transportation | |||||
| -40 °C | -40 °C | -40 °C | -40 °C | |
| 70 °C | 70 °C | 70 °C | 70 °C | |
Altitude during operation relating to sea level | |||||
| Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | Tmin … Tmax at 1080 hPa … 795 hPa (-1000 m … +2000 m) // Tmin … (Tmax – 10K) at 795 hPa … 658 hPa (+2000 m … +3500 m) // Tmin … (Tmax – 20K) at 658 hPa … 540 hPa (+3500 m … +5000 m) | |
Relative humidity | |||||
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | |||||
Use in stationary industrial systems | |||||
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Connection method | |||||
required front connector | 20-pin | 20-pin | 20-pin | 40-pin | |
Dimensions | |||||
Width | 40 mm | 40 mm | 40 mm | 40 mm | |
Height | 125 mm | 125 mm | 125 mm | 125 mm | |
Depth | 120 mm | 120 mm | 120 mm | 120 mm | |
Weights | |||||
Weight, approx. | 220 g | 220 g | 220 g | 272 g |