SIEMENS SIMODRIVE 611 Drives Modules

SIMODRIVE 611 Drives Modules

The SIMODRIVE 611 converter system is suitable for:

With the SIMODRIVE 611 converter system individual drive assemblies can be combined thus enabling fast and flexible synchronization of the drive performance and number of machine axes

  • Machine tools
  • Robot and manipulators
  • Mass production and jobshop production
  • Form and tool construction
  • Presses and packaging machines
  • Production machines for glass, wood, stone and textiles

Benefits

  • Configurable for speed / torque controls as well as position controls
  • Suitable for synchronous and induction motors
  • Compact design with 1-axis and 2-axis modules
  • Communication with PROFIBUS-DP, the most widely used field bus standard in the world
  • Powerful, user-operated start-up tool SimoCom U, with up to 64 separate traversing blocks that are individually programmable with acceleration, speed, target position, and more
  • All of the data in the package is stored on a removable memory submodule

Simodrive 611 Error Code List with Fault/Warning Numbers

000Alarm diagnostics not possible
Cause— Communications to the drive have been interrupted.
— Different versions of the ”SimoCom U” start-up and
parameterizing tool and the drive.
Remedy— Check the communications to the drive (cable, interfaces, … )
— The V_611U<Version>.acc file on the hard disk of the PG/PC
should be adapted to the drive as follows:
— Exit ”SimoCom U”
— Delete the V_611U<Version>.acc file (search and delete the file)
— Restart ”SimoCom U” and go online
The V_611U<Version>.acc file is now re-generated and is
harmonized to the drive version.
Never delete the file V000000.acc!
001The drive does not have firmware
CauseNo drive firmware on the memory module.
Remedy— Load the drive firmware via SimoCom U
— Insert the memory module with firmware
AcknowledgementPOWER ON
Stop responseSTOP II (SRM, SLM) STOP I (ARM)
002Computation time overflow. Suppl. info: \%X
CauseThe computation time of the drive processor is no longer sufficient for
the selected functions in the specified cycle times.
Supplementary information: only for siemens-internal error diagnostics
RemedyDisable functions which take up a lot of computation time, e.g.:
— Variable signaling function (P1620)
— Trace function
— Start-up with FFT or analyzing the step response
— Speed feedforward control (P0203)
— Min/Max memory (P1650.0)
— DAC output (max. 1 channel)
Increase cycle times:
— Current controller cycle (P1000)
— Speed controller cycle (P1001)
— Position controller cycle (P1009)
— Interpolation cycle (P1010)
AcknowledgementPOWER ON
Stop responseSTOP VIII
003NMI due to watchdog. Suppl. info: \%X
CauseThe watchdog timer on the control module has expired. The cause is a
hardware fault in the time basis on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy— Replace control module
AcknowledgementPOWER ON
Stop responseSTOP VIII
004Stack overflow. Suppl. info: \%X
CauseThe limits of the internal processor hardware stack or the software
stack in the data memory have been violated. The cause is probably a
hardware fault on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy— Power down / power up drive module
— Replace control module
AcknowledgementPOWER ON
Stop responseSTOP VIII

Popular Products Series

Siemens Simatic S7-200 CN

Siemens Simatic S7-200 CN are Made in China. MFG is Siemens China…

SIEMENS SINAMICS G130 Chassis Units

SINAMICS G130 chassis units have been designed for variable-speed drives in machine building and plant construction.
They have been specially tuned to the requirements of drives with quadratic or constant load characteristics with medium performance requirements without regenerative feedback.

GE QuickPanel family of Human Machine Interfaces Ge Fanuc HMI

The GE Automation QuickPanel+ HMI is more than just a human-machine interface; streamline your system with an OI/HMI, PLC/process controller, machine gateway, and data historian capable device all-in-one. It is made to handle industrial environments and is as easy to use as a smart phone or tablet, with just the swipe or tap of a finger.

Mitsubishi F740 Series Frequency Inverter

The FR-F700 Series was launched in 2004 as the successor to the FR-F500 Series VFD. With growing market demands for energy saving inverters in building automation, water processing and HVAC industries, the FR-F700 was able to exceed power-saving expectations in fan and pump applications by incorporating “OEC” (optimum excitation control) which combined maximum drive utilization with minimal power consumption.

Siemens PLC spare part 6AV 6DD 6SN 6ES5 6ES7

Main supply Siemens 6ES7 6AV6 6AV3 6SE7 Spare parts...

6RM80 SINAMICS DCM Cabinets

We provide the assembled version of 6RM80 product, and all the accessories are from the official Siemens, which are 100% tested and strictly tested before delivery.
Please consult our sales department for price.

Allen-Bradley 6176M Standard Industrial Monitors

Allen-Bradley 6176M Standard Industrial Monitors,6176M Standard Monitors are flat panel industrial color monitors for use in less demanding environments. All Standard Monitors have USB and RS232 touch screen inputs, DVI and VGA video inputs, and an On Screen Display (OSD) that enables image rotation, color pallet changes, and push button auto reset.

Allen-Bradley 6186M Performance Monitors

Bulletin 6186M - Performance Industrial Monitors




1200M,…
Load more