aotewell.net-logo4

Industry automation over 20 year

Sales@aotewell.com

24/7 Customer Support

Mon - Fri: 8:30 - 21:00

Online Store always open

Category: SITRANS P

Categore

HOME / Category: SITRANS P

SIEMENS

SIEMENS SITRANS P 4-20mA transmitter 7MF4433-1HA22-2AB6-Z A01

7MF4433-1HA22-2AB6-ZA01 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 0,3 to 30 bar (4.35 to 435 psi) , max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 Housing cover with window (setting: mA) With steel mounting bracket

Read More »
SIEMENS

SIEMENS SITRANS P 4-20mA transmitter 7MF4433-1FA22-1AB7-Z Y21

7MF4433-1FA22-1AB7-Z Y21 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 16 to 1600 mbar (6.424 to 642.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 Housing cover with window customized adjustment supplement Y21 required Adjustment digital indicator specify in plain text Y21: mBar, bar, kpa, mpa, …

Read More »
SIEMENS

SITRANS P HART 4-20mA transmitter 7MF4433-1FA02-2AD1

7MF4433-1FA02-2AD1 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 16 to 1600 mbar (6.424 to 642.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: han 7D plug (not with explosion proof) without visible digital indicator (digital display hidden, setting: mA)

Read More »
SIEMENS

SIEMENS SITRANS P transmitter 7MF4433-1DA22-2AB6-Z A02+A40+Y01+Y15

7MF4433-1DA22-2AB6-ZA02+A40+Y01+Y15 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 Housing cover with window (setting: mA) With stainless steel mounting bracket Sealing screw (1/4-18 npt) with valve in material of process flange Range (linear characteristic) specify in plain text: Y01:… to …mBar,kpa,mpa,… Stainless steel tag plate (measuring point description) Max.16 character, specify in plain text:

Read More »
SIEMENS

SIEMENS SITRANS transmitter 7MF4433-1DA22-1AB7-Z Y21

7MF4433-1DA22-1AB7- Z Y21 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 Housing cover with window customized adjustment supplement Y21 required Adjustment digital indicator specify in plain text Y21: mBar, bar, kpa, mpa, …

Read More »
SIEMENS

SIEMENS SITRANS P transmitter 7MF4233-1DA10-1NC7-Z A01+C11+Y01+Y21

7MF4233-1DA10-1NC7-Z A01+C11+Y01+Y21 SITRANS P DS III, HART, 4-20 MA transmitter for absolute pressure from pressure transmitter series Measuring cell filling silicone oil, normal cleaning Span: 8,3 to 250 mbar a (0.12 to 3.63 psi a), overload overload limit 6 bar Diaphragm stainless steel measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design With explosion protection FM + CSA (is + xp) Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window (digital indicator visible, customized adjustment, supplement Y21 required) With steel mounting bracket Test certificate according to standard IEC 60770-2 Range (linear characteristic) specify in plain text: Y01:…to …mBar, kpa, mpa,… Adjustment digital indicator specify in plain text Y21: mBar, bar, kpa, mpa, …

Read More »
SIEMENS

SIEMENS SITRANS P 4-20mA transmitter 7MF4033-1GA10-1AC6-Z A02+B11+E11+C12

7MF4033-1GA10-1AC6-ZA02+B11+E11+C12 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 4,0 … 400 bar g (58.0 … 5802 psi g), overload limit 600 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window With stainless steel mounting bracket Plate inscription: english Inspection certificate EN 10204-3.1: certificate pressurised parts Export approval Korea

Read More »
SIEMENS

SIEMENS SITRANS P HART 4-20mA transmitter 7MF4033-1EA60-1AB7-Z Y21

7MF4033-1EA60-1AB7-Z Y21 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 … 63 bar g (9.14 … 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required) Adjustment digital indicator specify plain text Y21: mBar, bar, kpa, mpa,…

Read More »
SIEMENS

SIEMENS SITRANS P 7MF4033-1DA00-1DB6-Z E46 Transmitter

7MF4033-1DA00-1DB6-Z E46 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 … 16 bar g (2.32 … 232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design Explosion protection EEx d cenelec) Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window Ex Approval IEC Ex (Ex d) (IEC Ex marking at the transmitter, no ATEX marking)

Read More »
SIEMENS

SIEMENS SITRANS P 4-20 mA transmitter 7MF4033-1DA00-1AB7

7MF4033-1DA00-1AB7 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 … 16 bar g (2.32 … 232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required)

Read More »
SIEMENS

SIEMENS SITRANS P 4-20mA transmitter 7MF4033-1CA60-1AB7-Z Y21

7MF4033-1CA60-1AB7- Z Y21 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 … 4 bar g (0.58 … 58 psi g), overload limit 10 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required) Adjustment digital indicator specify plain text Y21: mBar, bar, kpa, mpa,…

Read More »
SIEMENS

SIEMENS SITRANS P transmitter 7MF4033-1BA00-2BB1

7MF4033-1BA00-2BB1 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,01 … 1 bar g (0.15 … 14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd Explosion protection EEx ia Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA)

Read More »