Mitsubishi Inverter FR-F740 series

The FR-F700 frequency inverters range have been especially designed for pump and fan applications as well as heating, ventilation and air-conditioning installations (HVAC). The Mitsubishi Electric FR-F700 can lay claim to a 10-year service life thanks to advanced capacitors and ventilators. These features, along with its simple maintenance and automatic warning signal, make the FR-F700 one of the most reliable inverters on the market.

Series Name: Mitsubishi Inverter FR-F740
Share on facebook
Share on google
Share on twitter
Share on linkedin

Features

– Mitsubishi Inverter FR-F740 series more energy savings

– Ideal for fans and pump.

– Long life and simple maintenance.

– Reduction of electromagnetic noises (EMC filter)

– Simple operation.

– Enhanced network.

– Mitsubishi Inverter FR-F740 series Global compliance

– Enhanced PID function

– Tackling Power Loss and Recovery.

– Mitsubishi Inverter FR-F740 series, Energy Saving, Environmental Features, Safety.

Specifications

Application of inverter

Mitsubishi FR-F740

ND: Fans, Pumps, HVAC
HD: Crane, hoist, conveyor, compressor, punching press, winder, tool machine,…
Power supply3P, 380 to 480Vac 50/60 Hz
Rated capacity0.75-560 kW
Rated current2.1-1094 A (400V)
Output frequency range0.5 to 400 Hz
Starting Torque120% (3Hz) when set to simple magnetic flux vector control and slip compensation
Overload current rating120% 60s, 150% 3s (inverse time characteristics)
Control MethodV/f Control, V/f Control with PG, Open Loop Vector Control, Closed Loop Vector Control, Open Loop Vector
Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM
Braking unit
InputMulti-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, External-NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
OuputInverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm∗1, heatsink overheat pre-alarm, deceleration at an instantaneous power failure, PID control activated, PID output interruption, safety monitor output, safety monitor output 2, during retry, life alarm, current average value monitor, remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
Protection FunctionOvercurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat, input phase loss ∗3 ∗4, output side earth (ground) fault overcurrent at start∗3, output phase loss, externalthermal relay operation ∗3, PTC thermistor operation∗3, parameter error, PU disconnection, retry count excess ∗3, CPU fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value exceeded ∗3, safety circuit fault
Main Control FunctionsMaximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU
CommunicationPU connector

RS-485

Peripheral Devices and OptionsParameter unit (8 languages), Enclosure surface operation panel, Parameter unit connection cable, AC reactor, DC reactor, EMC Directive compliant noise filter, EMC compliant EMC filter installation attachment, Radio noise filter, Line noise filter, Brake resistor, High-duty brake resistor, Brake unit, Resistor unit, Discharging resistor, Power regeneration common converter Stand-alone reactor dedicated for the FR-CV, High power factor converter, Manual controller, DC tach. Follower, Three speed selector, Motorized speed setter, Speed detector, Master controller, Soft starter, Deviation detector, Preamplifier, Pilot generator, Deviation sensor, Frequency setting potentiometer, Analog frequency meter, Calibration resistor, FR Configurator SW3(VFD setup software)
Degree of protectionIP 00 open -chassis, IP 20 NEMA Type 1 enclosure

Ordering information

Application of inverter

Mitsubishi FR-F740

ND: Fans, Pumps, HVAC
HD: Crane, hoist, conveyor, compressor, punching press, winder, tool machine,…
Power supply3P, 380 to 480Vac 50/60 Hz
Rated capacity0.75-560 kW
Rated current2.1-1094 A (400V)
Output frequency range0.5 to 400 Hz
Starting Torque120% (3Hz) when set to simple magnetic flux vector control and slip compensation
Overload current rating120% 60s, 150% 3s (inverse time characteristics)
Control MethodV/f Control, V/f Control with PG, Open Loop Vector Control, Closed Loop Vector Control, Open Loop Vector
Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM
Braking unit
InputMulti-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, External-NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
OuputInverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm∗1, heatsink overheat pre-alarm, deceleration at an instantaneous power failure, PID control activated, PID output interruption, safety monitor output, safety monitor output 2, during retry, life alarm, current average value monitor, remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
Protection FunctionOvercurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat, input phase loss ∗3 ∗4, output side earth (ground) fault overcurrent at start∗3, output phase loss, externalthermal relay operation ∗3, PTC thermistor operation∗3, parameter error, PU disconnection, retry count excess ∗3, CPU fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value exceeded ∗3, safety circuit fault
Main Control FunctionsMaximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU
CommunicationPU connector

RS-485

Peripheral Devices and OptionsParameter unit (8 languages), Enclosure surface operation panel, Parameter unit connection cable, AC reactor, DC reactor, EMC Directive compliant noise filter, EMC compliant EMC filter installation attachment, Radio noise filter, Line noise filter, Brake resistor, High-duty brake resistor, Brake unit, Resistor unit, Discharging resistor, Power regeneration common converter Stand-alone reactor dedicated for the FR-CV, High power factor converter, Manual controller, DC tach. Follower, Three speed selector, Motorized speed setter, Speed detector, Master controller, Soft starter, Deviation detector, Preamplifier, Pilot generator, Deviation sensor, Frequency setting potentiometer, Analog frequency meter, Calibration resistor, FR Configurator SW3(VFD setup software)
Degree of protectionIP 00 open -chassis, IP 20 NEMA Type 1 enclosure

Mitsubishi Inverter FR-F740 Product Manual

 

Manual & Datasheet

#FileDescriptionDate addedAdded byFile sizeDownloads
1 pdf Mitsubishi-FR-F740-series-catalogue04/21/2020 00:58admin8 MB55

Please upload your inquiry list

Mitsubishi Inverter FR-F740

Buy Mitsubishi Inverter FR-F740 Series, 100% original and Made in Japan. Best price and Big stock.