Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Input current | ||
Current consumption (rated value) | 1 000 mA | |
Inrush current, typ. | 8 A | |
Power loss | ||
Power loss, typ. | 8 W | |
Memory | ||
Work memory | ||
● integrated | 48 kbyte; 48 KB / 16K instructions RAM (integrated) | |
Load memory | ||
● expandable FEPROM | Yes; Flash-EPROM | |
● expandable FEPROM, max. | 4 Mbyte | |
● integrated RAM, max. | 80 kbyte | |
Backup | ||
● present | Yes | |
● with battery | Yes; all blocks | |
● without battery | Yes; 4 KB: bit memory, counter, times and data | |
CPU processing times | ||
for bit operations, typ. | 0.3 µs | |
for bit operations, max. | 0.6 µs | |
for word operations, typ. | 1 µs | |
for fixed point arithmetic, typ. | 2 µs | |
for floating point arithmetic, typ. | 50 µs | |
for timer/counter operations, typ. | 12 µs | |
CPU-blocks | ||
DB | ||
● Number, max. | 255 | |
● Size, max. | 16 kbyte | |
FB | ||
● Number, max. | 192 | |
● Size, max. | 16 kbyte | |
FC | ||
● Number, max. | 192 | |
● Size, max. | 16 kbyte | |
OB | ||
● Description | see instruction list | |
● Size, max. | 16 kbyte | |
● Number of free cycle OBs | 1; OB 1 | |
● Number of time alarm OBs | 1; OB 10 | |
● Number of cyclic interrupt OBs | 1; OB 35 | |
● Number of process alarm OBs | 1; OB 40 | |
● Number of startup OBs | 1; OB 100 | |
Nesting depth | ||
● per priority class | 8 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 64 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 63 | |
Counting range | ||
— lower limit | 1 | |
— upper limit | 999 | |
S7 times | ||
● Number | 128 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 127 | |
Time range | ||
— lower limit | 10 ms | |
— upper limit | 9 990 s | |
Data areas and their retentivity | ||
Flag | ||
● Number, max. | 256 byte | |
● Retentivity available | Yes; MB 0 to MB 255 | |
● of which retentive with battery | 0 to 2 047 (M 0.0 to M 255.7, adjustable) | |
● of which retentive without battery | 0 to 2 047 (M 0.0 to M 255.7, adjustable) | |
Address area | ||
I/O address area | ||
● Inputs | 256 byte | |
● Outputs | 256 byte | |
Process image | ||
● Inputs | 128 byte | |
● Outputs | 128 byte | |
Digital channels | ||
● Inputs | 1 024 | |
— of which central | 1 024 | |
● Outputs | 1 024 | |
— of which central | 1 024 | |
Analog channels | ||
● Inputs | 256 | |
— of which central | 256 | |
● Outputs | 256 | |
— of which central | 128 | |
Addressing volume | ||
● Inputs | 122 byte | |
● Outputs | 122 byte | |
Hardware configuration | ||
Number of expansion units, max. | 3 | |
connectable programming devices/PCs | PGs/PCs with STEP 7 connectable via MPI interface | |
Number of modules per DP slave interface, max. | 32 | |
Number of DP masters | ||
● integrated | 0 | |
● via CP | 1; CP 342-5 | |
Number of operable FMs and CPs (recommended) | ||
● FM | 8 | |
● CP, PtP | 4 | |
● CP, LAN | 2 | |
Rack | ||
● Modules per rack, max. | 32 | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
Interfaces | ||
MPI | ||
● Cable length, max. | 9 100 m; without repeaters: 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with 16 star hubs or OLMs) | |
1. Interface | ||
Functionality | ||
● MPI | Yes | |
MPI | ||
● Number of nodes, max. | 32 | |
● Transmission rate, max. | 187.5 kbit/s | |
Services | ||
— PG/OP communication | Yes | |
— Global data communication | Yes | |
— S7 basic communication | Yes | |
— S7 communication | Yes | |
DP master | ||
User data per DP slave | ||
— User data per DP slave, max. | 122 byte | |
Communication functions | ||
PG/OP communication | Yes | |
Global data communication | ||
● supported | Yes | |
S7 basic communication | ||
● supported | Yes | |
S7 communication | ||
● supported | Yes | |
● as server | Yes | |
S5 compatible communication | ||
● supported | Yes; via loadable blocks | |
Standard communication (FMS) | ||
● supported | Yes; via loadable blocks | |
Number of connections | ||
● overall | ||
— of which dynamic | 8 | |
— of which static | 4 | |
Configuration | ||
Configuration software | ||
● STEP 7 | Yes; V5.0 | |
Programming | ||
● Command set | Binary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions | |
● Nesting levels | 8 | |
● Program organization | Linear, structured | |
● System functions (SFC) | Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions | |
Programming language | ||
— LAD | Yes | |
— FBD | Yes | |
— STL | Yes | |
— SCL | Yes | |
— CFC | Yes | |
— GRAPH | Yes | |
— HiGraph® | Yes | |
Software libraries | ||
— Process diagnostics | Yes | |
— Software controller | Yes; depending on the required memory space and the resulting execution time | |
Know-how protection | ||
● User program protection/password protection | Yes | |
Cycle time monitoring | ||
● lower limit | 1 ms | |
● upper limit | 6 000 ms | |
● adjustable | Yes | |
● preset | 150 ms | |
Dimensions | ||
Width | 80 mm | |
Height | 125 mm | |
Depth | 130 mm | |
Weights | ||
Weight, approx. | 530 g; Memory card 16 g |