The 6ES5482-8MA13 is an S5 I/O module for SIMATIC S5. It connects field wiring to the S5 bus without any change to the program. The datasheet quotes 24 V DC supply and IP20 protection.
| Model | 6ES5482-8MA13 |
|---|---|
| Manufacturer | SIEMENS |
| Product family | SIMATIC S5 |
| System compatibility | S5-90U/95U/100U/115U/135U/155U |
| Bus interface | S5 backplane (module bus) |
| Field wiring | Screw terminals on front connector |
| Supply voltage | 24 V DC (nominal) |
| Isolation | Galvanic isolation to bus |
| Protection degree | IP20 |
| Ambient temperature | 0 … 55 °C |
| Storage temperature | -25 … +70 °C |
| Relative humidity | 5 … 95 %, non-condensing |
| Engineering software | STEP 5 (S5-DOS/ST or STEP 5 V7.x) |
| Approvals | CE, UL |
| Product type | PLC I/O Module |
| Condition | Used, tested and cleaned |
| Packaging | Anti-static bag with foam protection |
| Stock Status | In stock, subject to prior sale |
| Country Of Origin | Not available |
| Warranty | 12 months |
Where it sits in the system
Communication runs over the S5 backplane. Field wires land on the front connector. Configuration is done in STEP 5 (S5-DOS/ST or STEP 5 V7.x). The working range is 0 … 55 °C. The datasheet quotes bus interface as S5 backplane (module bus), and field wiring at Screw terminals on front connector.
Before you order
The module number and the voltage level in the suffix have to match the old card, because S5 racks mix 24 V and 230 V modules. A photo of the old label is usually enough for us to confirm the suffix before you commit to the order.
What it is used for
Replacing a failed card on an S5 rack where the wiring is already in place. These cards are ordered from the machine drawing, one-for-one with the failed module.
Dispatch works like this: the unit is pulled against the order number, bench-checked the same day, and leaves in an anti-static bag with foam corners inside a double-wall carton. The invoice repeats the order number so it books against the right machine in your maintenance records.
Shipping is by air express by default, with the tracking number sent the day the parcel leaves. When several positions of the same order number are needed, they travel in one parcel so the cabinet goes back into service in a single visit.
Photograph the wiring before unplugging anything, so the replacement goes back the same way on the first attempt. Each unit is tested, cleaned and packed in an anti-static bag before it leaves the warehouse. Tell us the rack type and the slot number, and we can confirm whether this is the correct replacement.