BenefitsFuture-proof due to latest PC technology
Attractive visualization with industrial displays in modern design
Easy connection using a variety of interfaces
Proven reliability due to “Made for Industry” & SIMATIC quality
Economic solutions and fast availability
| DesignOperator control unit
12″ touch
15″ Touch
19″ Touch
Basic design
Versions – available directly from stock Each in 3 display sizes, 12″, 15″ or 19″:
|
SIMATIC IPC377E PANEL PC TECHNICAL SPECIFICATIONS
ARTICLE NUMBER | 6AV7230-0CA20-0BA0 | 6AV7230-0CA20-1BA0 | 6AV7230-0DA20-0BA0 | 6AV7230-0DA20-1BA0 | 6AV7230-0EA20-0BA0 | 6AV7230-0EA20-1BA0 | |
---|---|---|---|---|---|---|---|
SIMATIC IPC377E, 12″ TOUCH | SIMATIC IPC377E, 12″ TOUCH | SIMATIC IPC377E, 15″ TOUCH | SIMATIC IPC377E, 15″ TOUCH | SIMATIC IPC377E, 19″ TOUCH | SIMATIC IPC377E, 19″ TOUCH | ||
Installation type/mounting | |||||||
Mounting | Panel mount and VESA, horizontal and vertical | Panel mount and VESA, horizontal and vertical | Panel mount and VESA, horizontal and vertical | Panel mount and VESA, horizontal and vertical | Panel mount and VESA, horizontal and vertical | Panel mount and VESA, horizontal and vertical | |
Design | Panel PC, built-in unit | Panel PC, built-in unit | Panel PC, built-in unit | Panel PC, built-in unit | Panel PC, built-in unit | Panel PC, built-in unit | |
Supply voltage | |||||||
Type of supply voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC | |
Mains buffering | |||||||
| 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | |
Processor | |||||||
Processor type | Intel Celeron N3160 | Intel Celeron N3160 | Intel Celeron N3160 | Intel Celeron N3160 | Intel Celeron N3160 | Intel Celeron N3160 | |
Drives | |||||||
Hard disk | 500 GB HDD | 500 GB HDD | 500 GB HDD | 500 GB HDD | 500 GB HDD | 500 GB HDD | |
Memory | |||||||
Type of memory | DDR3L | DDR3L | DDR3L | DDR3L | DDR3L | DDR3L | |
Main memory | 4 GB (pre-installed) | 4 GB (pre-installed) | 4 GB (pre-installed) | 4 GB (pre-installed) | 4 GB (pre-installed) | 4 GB (pre-installed) | |
Capacity of main memory, max. | 8 Gbyte | 8 Gbyte | 8 Gbyte | 8 Gbyte | 8 Gbyte | 8 Gbyte | |
Hardware configuration | |||||||
Slots | |||||||
| 1x mPCIe (half-size), 1x mSATA (full-size) | 1x mPCIe (half-size), 1x mSATA (full-size) | 1x mPCIe (half-size), 1x mSATA (full-size) | 1x mPCIe (half-size), 1x mSATA (full-size) | 1x mPCIe (half-size), 1x mSATA (full-size) | 1x mPCIe (half-size), 1x mSATA (full-size) | |
Interfaces | |||||||
Number of industrial Ethernet interfaces | 2; 2x RJ45 (independent) | 2; 2x RJ45 (independent) | 2; 2x RJ45 (independent) | 2; 2x RJ45 (independent) | 2; 2x RJ45 (independent) | 2; 2x RJ45 (independent) | |
USB port | 2x USB 2.0, 2x USB 3.0 (high current) | 2x USB 2.0, 2x USB 3.0 (high current) | 2x USB 2.0, 2x USB 3.0 (high current) | 2x USB 2.0, 2x USB 3.0 (high current) | 2x USB 2.0, 2x USB 3.0 (high current) | 2x USB 2.0, 2x USB 3.0 (high current) | |
Video interfaces | |||||||
| 1x DisplayPort, 1x VGA | 1x DisplayPort, 1x VGA | 1x DisplayPort, 1x VGA | 1x DisplayPort, 1x VGA | 1x DisplayPort, 1x VGA | 1x DisplayPort, 1x VGA | |
Industrial Ethernet | |||||||
| 2 x Ethernet (RJ45) | 2 x Ethernet (RJ45) | 2 x Ethernet (RJ45) | 2 x Ethernet (RJ45) | 2 x Ethernet (RJ45) | 2 x Ethernet (RJ45) | |
| Yes | Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | Yes | |
Protocols | |||||||
Protocols (Ethernet) | |||||||
| Yes | Yes | Yes | Yes | Yes | Yes | |
Integrated Functions | |||||||
Monitoring functions | |||||||
| Yes | Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | Yes | |
| POWER, HDD | POWER, HDD | POWER, HDD | POWER, HDD | POWER, HDD | POWER, HDD | |
| No | No | No | No | No | No | |
EMC | |||||||
Interference immunity against discharge of static electricity | |||||||
| |||||||
| 8 kV | 8 kV | 8 kV | 8 kV | 8 kV | 8 kV | |
| 6 kV | 6 kV | 6 kV | 6 kV | 6 kV | 6 kV | |
Interference immunity against high-frequency electromagnetic fields | |||||||
| 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | 10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3 | |
Interference immunity to cable-borne interference | |||||||
| ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | ±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground) | |
| ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | ±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge | |
| ±1 kV acc. to IEC 61000-4-4, Burst | ±1 kV acc. to IEC 61000-4-4, Burst | ±1 kV acc. to IEC 61000-4-4, Burst | ±1 kV acc. to IEC 61000-4-4, Burst | ±1 kV acc. to IEC 61000-4-4, Burst | ±1 kV acc. to IEC 61000-4-4, Burst | |
Interference immunity against voltage surge | |||||||
| ±2 kV acc. to IEC 61000-4-5, surge asymmetric | ±2 kV acc. to IEC 61000-4-5, surge asymmetric | ±2 kV acc. to IEC 61000-4-5, surge asymmetric | ±2 kV acc. to IEC 61000-4-5, surge asymmetric | ±2 kV acc. to IEC 61000-4-5, surge asymmetric | ±2 kV acc. to IEC 61000-4-5, surge asymmetric | |
| ±1 kV acc. to IEC 61000-4-5, surge symmetric | ±1 kV acc. to IEC 61000-4-5, surge symmetric | ±1 kV acc. to IEC 61000-4-5, surge symmetric | ±1 kV acc. to IEC 61000-4-5, surge symmetric | ±1 kV acc. to IEC 61000-4-5, surge symmetric | ±1 kV acc. to IEC 61000-4-5, surge symmetric | |
Interference immunity to magnetic fields | |||||||
| 100 A/m; to IEC 61000-4-8 | 100 A/m; to IEC 61000-4-8 | 100 A/m; to IEC 61000-4-8 | 100 A/m; to IEC 61000-4-8 | 100 A/m; to IEC 61000-4-8 | 100 A/m; to IEC 61000-4-8 | |
Degree and class of protection | |||||||
IP (at the front) | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | |
IP (rear) | IP40 | IP40 | IP40 | IP40 | IP40 | IP40 | |
Standards, approvals, certificates | |||||||
CE mark | Yes | Yes | Yes | Yes | Yes | Yes | |
cULus | No | No | No | No | No | No | |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes | Yes | Yes | |
EAC (formerly Gost-R) | Yes | Yes | Yes | Yes | Yes | Yes | |
FCC | Yes | Yes | Yes | Yes | Yes | Yes | |
Dust protection | Protection against foreign bodies > 1 mm | Protection against foreign bodies > 1 mm | Protection against foreign bodies > 1 mm | Protection against foreign bodies > 1 mm | Protection against foreign bodies > 1 mm | Protection against foreign bodies > 1 mm | |
Ambient conditions | |||||||
Ambient temperature during operation | |||||||
| 0 to +40 °C | 0 to +40 °C | 0 to +40 °C | 0 to +40 °C | 0 to +40 °C | 0 to +40 °C | |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | |
| 40 °C | 40 °C | 40 °C | 40 °C | 40 °C | 40 °C | |
Ambient temperature during storage/transportation | |||||||
| -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | |
| 60 °C | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C | |
Relative humidity | |||||||
| Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) | |
Vibrations | |||||||
| 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | 58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6 | |
Shock testing | |||||||
| With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27 | |
Operating systems | |||||||
without operating system | Yes | Yes | Yes | Yes | Yes | Yes | |
Dimensions | |||||||
Width | 320 mm | 320 mm | 320 mm | 320 mm | 320 mm | 320 mm | |
Height | 225.6 mm | 225.6 mm | 225.6 mm | 225.6 mm | 225.6 mm | 225.6 mm | |
Depth | 95.2 mm | 95.2 mm | 95.2 mm | 95.2 mm | 95.2 mm | 95.2 mm |