YOKOGAWA EJA210A, EJA220A Flange Mounted Diff. Pressure Transmitters
The high-performance EJA210A and EJA220A flange mounted differential pressure transmitter can be used to measure levels of densities of solidifying or precipitating liquids.
The high performance flange mounted differential pressure transmitter models YOKOGAWA EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure.
The YOKOGAWA EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
Features
Excellent performance and stability
Compact and light-weight design
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
Fieldbus communication capability
Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.
EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.
Specifications
YOKOGAWA EJA210A / EJA220A Liquid Level Differential Pressure Transmitter | ||
M Capsule | H Capsule | |
Range | -100 to 100 kPa (-400 to 400 inH2O) | -500 to 500 kPa (-2000 to 2000 inH2O) |
Span | 1 to 100 kPa (4 to 400 inH2O) | 5 to 500 kPa (20 to 2000 inH2O) |
Accuracy | ±0.2% | ±0.2% |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | |
Certificates | FM, CENELEC ATEX, CSA, IECEx | |
Output | 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | |
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | |
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | |
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | |
Maximum working pressure | Flange rating pressure | |
Mounting | Flange mounting | |
Process flange size | EJA210A: 3-inch (80mm), 2-inch (50mm) EJA220A: 4-inch (100mm), 3-inch (80mm) | |
Diaphragm material (High side) | SUS316L, Hastelloy C-276, Tantalum | |
Process flange material | S25C, SUS304, SUS316 | |
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |