Plants that keep Yokogawa pressure transmitter installations on the original hardware order the EJA530E when one position fails. It turns differential, gauge or absolute pressure into a 4 … 20 mA signal for the control room. The datasheet quotes 10.5 … 42 V DC, loop powered supply and IP67 weatherproof housing protection.
| Model | EJA530E |
|---|---|
| Manufacturer | Yokogawa Electric |
| Product type | Pressure transmitter |
| Sensing technology | DPharp digital sensor |
| Output signal | 4 … 20 mA DC |
| Communication | HART or BRAIN per option code |
| Measurement type | Fixed by the order number (differential, gauge, absolute, flow or level) |
| Mounting | Traditional mount or in-line mount per order number |
| Supply voltage | 10.5 … 42 V DC, loop powered |
| Ambient temperature | typically -40 … 85 °C per datasheet |
| Protection degree | IP67 weatherproof housing |
| Diagnostics | Self-diagnostics with status output |
| Approvals | Per option code (ATEX / IECEx variants) |
| Product family | YOKOGAWA EJA |
| Condition | Tested and cleaned, in good working order |
| Packaging | Anti-static bag with foam protection |
| Stock Status | In stock, subject to prior sale |
| Country Of Origin | Not available |
| Warranty | 12 months |
Position in the installation
The working range is typically -40 … 85 °C per datasheet. The datasheet quotes diagnostics as Self-diagnostics with status output, and protection degree at IP67 weatherproof housing.
Compatibility notes
The range, seal and output option are all coded in the suffix, so read the full order number off the rating plate before ordering. Two units with the same family name can carry different suffixes and behave differently, so the full string matters more than the model family.
Where it is used
Process lines measured with the EJA series where one transmitter has drifted or stopped responding. Refineries, chemical plants and water utilities run EJA transmitters on header manifolds, distillation columns and pump discharge lines.
Every parcel leaves with the commercial invoice and packing list naming the order number, which keeps customs paperwork aligned with the part on the label. Air express is the default; consolidated freight is possible when several positions travel together.
For export the unit is packed in an anti-static bag with foam corner protection and shipped in a double-wall carton. The commercial invoice carries the original order number, which keeps the part booked against the right maintenance line.
Keep the front connector and its wiring in place when you swap the part, because the terminal assignment does not change within the same type. Every unit is bench-tested and photographed before packing, so what you receive is what was inspected. If the label is unreadable, send a photo of the part and its slot and we will identify it for you.